104 research outputs found
Safety and efficacy of dronedarone from clinical trials to real-world evidence: implications for its use in atrial fibrillation.
Efficacy and safety of dronedarone was shown in the ATHENA trial for paroxysmal or persistent atrial fibrillation (AF) patients. Further trials revealed safety concerns in patients with heart failure and permanent AF. This review summarizes insights from recent real-world studies and meta-analyses, including reports on efficacy, with focus on liver safety, mortality risk in patients with paroxysmal/persistent AF, and interactions of dronedarone with direct oral anticoagulants. Reports of rapidly progressing liver failure in dronedarone-prescribed patients in 2011 led to regulatory cautions about potential liver toxicity. Recent real-world evidence suggests dronedarone liver safety profile is similar to other antiarrhythmics and liver toxicity could be equally common with many Class III antiarrhythmics. Dronedarone safety concerns (increased mortality in patients with permanent AF) were raised based on randomized controlled trials (RCT) (ANDROMEDA and PALLAS), but comedication with digoxin may have increased the mortality rates in PALLAS, considering the dronedarone-digoxin pharmacokinetic (PK) interaction. Real-world data on apixaban-dronedarone interactions and edoxaban RCT observations suggest no significant safety risks for these drug combinations. Median trough plasma concentrations of dabigatran 110 mg during concomitant use with dronedarone are at acceptable levels, while PK data on the rivaroxaban-dronedarone interaction are unavailable. In RCTs and real-world studies, dronedarone significantly reduces AF burden and cardiovascular hospitalizations, and demonstrates a low risk for proarrhythmia in patients with paroxysmal or persistent AF. The concerns on liver safety must be balanced against the significant reduction in hospitalizations in patients with non-permanent AF and low risk for proarrhythmias following dronedarone treatment
Treatment of atrial fibrillation with a dual defibrillator in heart failure patients (TRADE HF): protocol for a randomized clinical trial.
Background: Heart failure(HF) and atrial fibrillation(AF) frequently coexist in the same patient and are associated with increased mortality and frequent hospitalizations. As the concomitance of AF and HF is often associated with a poor prognosis, the prompt treatment of AF in HF patients may significantly improve outcome.Methods/design: Recent implantable cardiac resynchronization (CRT) devices allow electrical therapies to treat AF automatically. TRADE-HF (trial registration: NCT00345592; http://www.clinicaltrials.gov) is a prospective, randomized, double arm study aimed at demonstrating the efficacy of an automatic, device-based therapy for treatment of atrial tachycardia and fibrillation(AT/AF) in patients indicated for CRT. The study compares automatic electrical therapy to a traditional more usual treatment of AT/AF: the goal is to demonstrate a reduction in a combined endpoint of unplanned hospitalizations for cardiac reasons, death from cardiovascular causes or permanent AF when using automatic atrial therapy as compared to the traditional approach involving hospitalization for symptoms and in-hospital treatment of AT/AF.Discussion: CRT pacemaker with the additional ability to convert AF as well as ventricular arrhythmias may play a simultaneous role in rhythm control and HF treatment. The value of the systematic implantation of CRT ICDs with the capacity to deliver atrial therapy in HF patients at risk of AF has not yet been explored. The TRADE-HF study will assess in CRT patients whether a strategy based on automatic management of atrial arrhythmias might be a valuable option to reduce the number of hospital admission and to reduce the progression the arrhythmia to a permanent for
How to use implantable loop recorders in clinical trials and hybrid therapy
Epidemiological studies show that atrial fibrillation (AF) is associated with a doubling of mortality, even after adjustment for confounders. AF can be asymptomatic, but this does not decrease the thromboembolic risk of the patient. Office ECGs, occasional 24-h Holter recordings and long-term ECG event recording might not be sensitive and accurate enough in patients with AF, especially in those with paroxysmal episodes. In one study, 7 days of continuous monitoring with event recorders detected paroxysmal AF in 20 of 65 patients with a previous negative 24-h Holter recording. Over the last decade, enormous improvements have been made in the technology of implantable devices, which can now store significant information regarding heart rhythm. The first subcutaneous implantable monitor (Reveal XT, Medtronic) was validated for continuous AF monitoring by the XPECT study. The dedicated AF detection algorithm uses irregularity and incoherence of R–R intervals to identify and classify patterns in ventricular conduction. Its sensitivity in identifying patients with AF is >96%. Numerous clinical data from continuous monitoring of AF have recently been published. The first applications of this technology have been in the field of surgical and catheter AF ablation. With regard to cryptogenic stroke, an international randomized trial is ongoing to compare standard care with standard care plus the implantable cardiac monitor for AF detection in patients discharged with the diagnosis of cryptogenic stroke: the Crystal AF trial. Continuous AF monitoring provides an optimal picture of daily AF burden, both symptomatic and asymptomatic. Implantable cardiac monitors have high sensitivity, enable better assessment of therapy success and may guide further AF therapy
Use of an Atrial Lead with Very Short Tip-To-Ring Spacing Avoids Oversensing of Far-Field R-Wave
The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming.Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation.A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62).The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization.ClinicalTrials.gov NCT00512915
Surviving Mousepox Infection Requires the Complement System
Poxviruses subvert the host immune response by producing immunomodulatory proteins, including a complement regulatory protein. Ectromelia virus provides a mouse model for smallpox where the virus and the host's immune response have co-evolved. Using this model, our study investigated the role of the complement system during a poxvirus infection. By multiple inoculation routes, ectromelia virus caused increased mortality by 7 to 10 days post-infection in C57BL/6 mice that lack C3, the central component of the complement cascade. In C3−/− mice, ectromelia virus disseminated earlier to target organs and generated higher peak titers compared to the congenic controls. Also, increased hepatic inflammation and necrosis correlated with these higher tissue titers and likely contributed to the morbidity in the C3−/− mice. In vitro, the complement system in naïve C57BL/6 mouse sera neutralized ectromelia virus, primarily through the recognition of the virion by natural antibody and activation of the classical and alternative pathways. Sera deficient in classical or alternative pathway components or antibody had reduced ability to neutralize viral particles, which likely contributed to increased viral dissemination and disease severity in vivo. The increased mortality of C4−/− or Factor B−/− mice also indicates that these two pathways of complement activation are required for survival. In summary, the complement system acts in the first few minutes, hours, and days to control this poxviral infection until the adaptive immune response can react, and loss of this system results in lethal infection
Effectiveness of cardiac resynchronization therapy in heart failure patients with valvular heart disease: comparison with patients affected by ischaemic heart disease or dilated cardiomyopathy. The InSync/InSync ICD Italian Registry
AimsTo analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients.Methods and resultsPatients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT implant. Patients with valvular heart disease treated with CRT (n = 108) in comparison with ischaemic heart disease (n = 737) and dilated cardiomyopathy (n = 635) patients presented: (i) a higher prevalence of chronic atrial fibrillation, with atrioventricular node ablation performed in around half of the cases; (ii) a similar clinical and echocardiographic profile at baseline; (iii) a similar improvement of LVEF and a similar reduction in ventricular volumes at 6-12 months; (iv) a favourable clinical response at 12 months with an improvement of the clinical composite score similar to that occurring in patients with dilated cardiomyopathy and more pronounced than that observed in patients with ischaemic heart disease; (v) a long-term outcome, in term of freedom from death or heart transplantation, similar to patients affected by ischaemic heart disease and basically more severe than that of patients affected by dilated cardiomyopathy.ConclusionIn 'real world' clinical practice, CRT appears to be effective also in patients with valvular heart disease. However, in this group of patients the outcome after CRT does not precisely overlap any of the two other groups of patients, for which much more data are currently available
Laparoscopy in management of appendicitis in high-, middle-, and low-income countries: a multicenter, prospective, cohort study.
BACKGROUND: Appendicitis is the most common abdominal surgical emergency worldwide. Differences between high- and low-income settings in the availability of laparoscopic appendectomy, alternative management choices, and outcomes are poorly described. The aim was to identify variation in surgical management and outcomes of appendicitis within low-, middle-, and high-Human Development Index (HDI) countries worldwide. METHODS: This is a multicenter, international prospective cohort study. Consecutive sampling of patients undergoing emergency appendectomy over 6 months was conducted. Follow-up lasted 30 days. RESULTS: 4546 patients from 52 countries underwent appendectomy (2499 high-, 1540 middle-, and 507 low-HDI groups). Surgical site infection (SSI) rates were higher in low-HDI (OR 2.57, 95% CI 1.33-4.99, p = 0.005) but not middle-HDI countries (OR 1.38, 95% CI 0.76-2.52, p = 0.291), compared with high-HDI countries after adjustment. A laparoscopic approach was common in high-HDI countries (1693/2499, 67.7%), but infrequent in low-HDI (41/507, 8.1%) and middle-HDI (132/1540, 8.6%) groups. After accounting for case-mix, laparoscopy was still associated with fewer overall complications (OR 0.55, 95% CI 0.42-0.71, p < 0.001) and SSIs (OR 0.22, 95% CI 0.14-0.33, p < 0.001). In propensity-score matched groups within low-/middle-HDI countries, laparoscopy was still associated with fewer overall complications (OR 0.23 95% CI 0.11-0.44) and SSI (OR 0.21 95% CI 0.09-0.45). CONCLUSION: A laparoscopic approach is associated with better outcomes and availability appears to differ by country HDI. Despite the profound clinical, operational, and financial barriers to its widespread introduction, laparoscopy could significantly improve outcomes for patients in low-resource environments. TRIAL REGISTRATION: NCT02179112
Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy
Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe
- …