576 research outputs found

    Jaw Dysfunction Is Associated with Neck Disability and Muscle Tenderness in Subjects with and without Chronic Temporomandibular Disorders

    Get PDF
    Purpose. Tender points in the neck are common in patients with temporomandibular disorders (TMD). However, the correlation among neck disability, jaw dysfunction, and muscle tenderness in subjects with TMD still needs further investigation. This study investigated the correlation among neck disability, jaw dysfunction, and muscle tenderness in subjects with and without chronic TMD. Participants. Forty females between 19 and 49 years old were included in this study.There were 20 healthy controls and 20 subjects who had chronic TMD and neck disability. Methods. Subjects completed the neck disability index and the limitations of daily functions in TMD questionnaires. Tenderness of the masticatory and cervical muscles was measured using an algometer. Results. The correlation between jaw disability and neck disability was significantly high (� = 0.915, � \u3c 0.05). The correlation between level of muscle tenderness in the masticatory and cervical muscles with jaw dysfunction and neck disability showed fair to moderate correlations (� = 0.32–0.65). Conclusion. High levels of muscle tenderness in upper trapezius and temporalis muscles correlated with high levels of jaw and neck dysfunction. Moreover, high levels of neck disability correlated with high levels of jaw disability.These findings emphasize the importance of considering the neck and its structures when evaluating and treating patients with TMD

    The impact of different calibration matrices on the determination of insulin-like growth factor 1 by high-resolution-LC-MS in acromegalic and growth hormone deficient patients

    Get PDF
    Objectives: Calibration is an important source of variability in liquid chromatography mass spectrometry (LC-MS) methods for insulin-like growth factor 1 (IGF-1). This study investigated the impact of different calibrator matrices on IGF-1 measurements by LC-MS. Moreover, the comparability of immunoassays and LC-MS was assessed. Design & Methods: Calibrators from 12.5 to 2009 ng/ml were prepared by spiking WHO international Standard (ID 02/254 NIBSC, UK) into the following matrices: native human plasma, fresh charcoal-treated human plasma (FCTHP), old charcoal-treated human plasma, deionized water, bovine serum albumin (BSA), and rat plasma (RP). A validated in-house LC-MS method was calibrated repeatedly with these calibrators. Then, serum samples from 197 growth hormone excess and deficiency patients were analysed with each calibration. Results: The seven calibration curves had different slopes leading to markedly different patient results. The largest differences in IGF-1 concentration from the median (interquartile range) was observed with the calibrator in water and the calibrator in RP (336.4 [279.6–417.0] vs. 112.5 [71.2–171.2], p < 0.001). The smallest difference was observed with calibrators in FCTHP and BSA (141.8 [102.0–198.5] vs. 127.9 [86.9–186.0], p < 0.049). Compared to LC-MS with calibrators in FCTHP, immunoassays showed relevant proportional bias (range: −43% to −68%), constant bias (range: 22.84 to 57.29 ng/ml) and pronounced scatter. Comparing the immunoassays with each other revealed proportional bias of up to 24%. Conclusions: The calibrator matrix is critical for the measurement of IGF-1 by LC-MS. Regardless of the calibrator matrix, LC-MS shows poor agreement with immunoassays. Also, the agreement between different immunoassays is variable

    Power line electrocution as an overlooked threat to Lear's Macaw (Anodorhynchus leari)

    Get PDF
    Electrocution can pose a serious threat to large birds, particularly threatened species with low population sizes. However, few studies have focused on the impacts of electrocution on large parrots such as the Endangered Lear's Macaw Anodorhynchus leari, endemic to the Brazilian Caatinga. Here, we compile and describe 31 electrocution events, as reported by villagers, indicating that electrocution may be an important threat to Lear's Macaw. We suggest a research and monitoring agenda to better understand the spatial and temporal patterns of this impact and recommend some immediate mitigation measures for decreasing electrocutions.info:eu-repo/semantics/submittedVersio

    Multicenter randomized, double-blind controlled trial to evaluate the efficacy of laser therapy for the treatment of severe oral mucositis induced by chemotherapy in children: laMPO RCT

    Get PDF
    Objectives: To demonstrate the efficacy of laser photobiomodulation (PBM) compared to that of placebo on severe oral mucositis (OM) in pediatric oncology patients. The primary objective was the reduction of OM grade (World Health Organization [WHO] scale) 7 days after starting PBM. Secondary objectives were reduction of pain, analgesic consumption, and incidence of side effects. Methods: One hundred and one children with WHO grade\ua0>\ua02 chemotherapy-induced OM were enrolled in eight Italian hospitals. Patients were randomized to either PBM or sham treatment for four consecutive days (days +1 to +4). On days +4, +7, and +11, OM grade, pain (following a 0\u201310 numeric pain rating scale, NRS) and need for analgesics were evaluated by an operator blinded to treatment. Results: Fifty-one patients were allocated to the PBM group, and 50 were allocated to the sham group. In total, 93.7% of PBM patients and 72% of sham patients had OM grade\ua0<\ua03 WHO on day +7 (P\ua0=\ua00.01). A significant reduction of pain was registered on day +7 in the PBM versus sham group (NRS 1 [0\u20133] vs. 2.5 [1\u20135], P\ua0<\ua00.006). Reduced use of analgesics was reported in the PBM group, although it was not statistically significant. No significant adverse events attributable to treatment were recorded. Conclusions: PBM is a safe, feasible, and effective treatment for children affected by chemotherapy-induced OM, as it accelerates mucosal recovery and reduces pain

    Visceral Manipulation Decreases Pain, Increases Cervical Mobility and Electromyographic Activity of the Upper Trapezius Muscle in Non-Specific Neck Pain Subjects with Functional Dyspepsia: Two Case Reports

    Get PDF
    Background and Purpose: The lack of clear knowledge about the etiology of nonspecific neck pain (NS-NP) strengthens the need for other mech-anisms, still poorly described in the literature, to be investigated. Therefore, a quantitative analysis of two cases of NS-NP in subjects with functiona dyspepsia was conducted in order to verify the immediate and seven-day postintervention effects of visceral manipulation (VM) to the stomach and liver on neck pain, cervical range of motion (ROM), and electromyographic (EMG) activity of the upper trapezius muscle. Case Description: Case A was an 18-year-old female with a complaint of nonspecific neck pain for one year, with reported pain on waking, momentary intermittent pain, and occasional symptoms of paresthesia in the upper limbs. Case B was a 25-year-old female with a complaint of cervical pain for one year, accompanied by pain in the unilateral temporomandibular joint, and medial thoracic region. Both cases presented functional dyspepsia.Outcomes: The results demonstrated (sub-jects A and B, respectively) a general increase in cervical ROM (range: 12.5% to 44.44%) and amplitude of the EMG signal (immediately postintervention: 57.62 and 20.78; post seven days: 53.54% and 18.83%), and an increase in muscle fiber conduction velocity immediately postintervention (4.44% and 7.44%) and a de-crease seven days postintervention (25.25% and 21.18%). For pain, a decrease was observed immediately postintervention (23.07% and 76.92%) and seven days postintervention (100% for both subjects). Discussion: A single VM provided important clinical improvement in neck pain, cervical spine range of motion, and EMG activity of the upper trapezius muscle, immediately and seven days postintervention in two NS-NP subjects with func-tional dyspepsia

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore