1,177 research outputs found
‘O sibling, where art thou?’ – a review of avian sibling recognition with respect to the mammalian literature
Avian literature on sibling recognition is rare compared to that developed by mammalian researchers. We compare avian and mammalian research on sibling recognition to identify why avian work is rare, how approaches differ and what avian and mammalian researchers can learn from each other. Three factors: (1) biological differences between birds and mammals, (2) conceptual biases and (3) practical constraints, appear to influence our current understanding. Avian research focuses on colonial species because sibling recognition is considered adaptive where ‘mixing potential’ of dependent young is high; research on a wider range of species, breeding systems and ecological conditions is now needed. Studies of acoustic recognition cues dominate avian literature; other types of cues (e.g. visual, olfactory) deserve further attention. The effect of gender on avian sibling recognition has yet to be investigated; mammalian work shows that gender can have important influences. Most importantly, many researchers assume that birds recognise siblings through ‘direct familiarisation’ (commonly known as associative learning or familiarity); future experiments should also incorporate tests for ‘indirect familiarisation’ (commonly known as phenotype matching). If direct familiarisation proves crucial, avian research should investigate how periods of separation influence sibling discrimination. Mammalian researchers typically interpret sibling recognition in broad functional terms (nepotism, optimal outbreeding); some avian researchers more successfully identify specific and testable adaptive explanations, with greater relevance to natural contexts. We end by reporting exciting discoveries from recent studies of avian sibling recognition that inspire further interest in this topic
An x-ray diffraction study of corneal structure in mimecan-deficient mice
PURPOSE: Keratan sulfate proteoglycans (KSPGs) in the corneal stroma are believed to influence collagen fibrillar arrangement. This study was performed to investigate the fibrillar architecture of the corneal stroma in mice homozygous for a null mutation in the corneal KSPG, mimecan.
METHODS: Wild-type (n = 9) and mimecan-deficient (n = 10) mouse corneas were investigated by low-angle synchrotron x-ray diffraction to establish the average collagen fibrillar spacing, average collagen fibril diameter, and level of fibrillar organization in the stromal array.
RESULTS: The mean collagen fibril diameter in the corneas of mimecan-null mice, as an average throughout the whole thickness of the tissue, was not appreciably different from normal (35.6 +/- 1.1 nm vs. 35.9 +/- 1.0 nm). Average center-to-center collagen fibrillar spacing in the mutant corneas measured 52.6 +/- 2.6 nm, similar to the 53.3 +/- 4.0 nm found in wild-type mice. The degree of local order in the collagen fibrillar array, as indicated by the height-width (H:W) ratio of the background-subtracted interfibrillar x-ray reflection, was also not significantly changed in mimecan-null corneas (23.4 +/- 5.6), when compared with the corneas of wild-types (28.2 +/- 4.8).
CONCLUSIONS: On average, throughout the whole depth of the corneal stroma, collagen fibrils in mimecan-null mice, unlike collagen fibrils in lumican-null mice and keratocan-null mice, are of a normal diameter and are normally spaced and arranged. This indicates that, compared with lumican and keratocan, mimecan has a lesser role in the control of stromal architecture in mouse cornea
Exact Bayesian curve fitting and signal segmentation.
We consider regression models where the underlying functional relationship between the response and the explanatory variable is modeled as independent linear regressions on disjoint segments. We present an algorithm for perfect simulation from the posterior distribution of such a model, even allowing for an unknown number of segments and an unknown model order for the linear regressions within each segment. The algorithm is simple, can scale well to large data sets, and avoids the problem of diagnosing convergence that is present with Monte Carlo Markov Chain (MCMC) approaches to this problem. We demonstrate our algorithm on standard denoising problems, on a piecewise constant AR model, and on a speech segmentation problem
Do Zebra Finch Parents Fail to Recognise Their Own Offspring?
Individual recognition systems require the sender to be individually distinctive and the receiver to be able to perceive differences between individuals and react accordingly. Many studies have demonstrated that acoustic signals of almost any species contain individualized information. However, fewer studies have tested experimentally if those signals are used for individual recognition by potential receivers. While laboratory studies using zebra finches have shown that fledglings recognize their parents by their “distance call”, mutual recognition using the same call type has not been demonstrated yet. In a laboratory study with zebra finches, we first quantified between-individual acoustic variation in distance calls of fledglings. In a second step, we tested recognition of fledgling calls by parents using playback experiments. With a discriminant function analysis, we show that individuals are highly distinctive and most measured parameters show very high potential to encode for individuality. The response pattern of zebra finch parents shows that they do react to calls of fledglings, however they do not distinguish between own and unfamiliar offspring, despite individual distinctiveness. This finding is interesting in light of the observation of a high percentage of misdirected feedings in our communal breeding aviaries. Our results demonstrate the importance of adopting a receiver's perspective and suggest that variation in fledgling contact calls might not be used in individual recognition of offspring
An intercomparison of measurement systems for vapor and particulate phase concentrations of formic and acetic acids
During June 1986, eight systems for measuring vapor phase and four for measuring particulate phase concentrations of formic acid (HCOOH) and acetic acid (CH_3COOH) were intercompared in central Virginia. HCOOH and CH_3COOH vapors were sampled by condensate, mist, Chromosorb 103 GC resin, NaOH-coated annular denuders, NaOH impregnated quartz filters, K_2CO_3 and Na_2CO_3 impregnated cellulose filters, and Nylasorb membranes. Atmospheric aerosol was collected on Teflon and Nuclepore filters using both hi-vol and lo-vol systems to measure particulate phase concentrations. Samples were collected during 31 discrete day and night intervals of 0.5–2 hour duration over a 4-day period. Performance of the mist chamber and K_2CO_3 impregnated filter techniques were also evaluated using zero air and ambient air spiked with HCOOH_g, CH_3COOH_g, and formaldehyde (CH_2O_g) from permeation sources. Results of this intercomparison show significant systematic and episodic artifacts among many currently deployed measurement systems for HCOOH_g and CH_3COOH_g. The spiking experiments revealed no significant interferences for the mist chamber technique and results generated by the mist chamber and denuder techniques were statistically indistinguishable. The condensate technique showed general agreement with the mist chamber and denuder methods, but episodic bias between these systems was inferred from large and significant differences observed during the first day of sampling. Nylasorb membranes are unacceptable for collecting carboxylic acid vapors as they did not retain HCOOH_g and CH_3COOH_g quantitatively. Strong base impregnated filter and GC resin sampling techniques are prone to large positive interferences apparently resulting, in part, from reactions involving CH_2O_g to generate HCOOH and CH_3COOH subsequent to collection. Significant bias presumably associated with differences in postcollection handling was observed for particulate phase measurements by participating groups. Analytical bias did not contribute significantly to differences in vapor and particulate phase measurements
Graphene Photonics and Optoelectronics
The richness of optical and electronic properties of graphene attracts
enormous interest. Graphene has high mobility and optical transparency, in
addition to flexibility, robustness and environmental stability. So far, the
main focus has been on fundamental physics and electronic devices. However, we
believe its true potential to be in photonics and optoelectronics, where the
combination of its unique optical and electronic properties can be fully
exploited, even in the absence of a bandgap, and the linear dispersion of the
Dirac electrons enables ultra-wide-band tunability. The rise of graphene in
photonics and optoelectronics is shown by several recent results, ranging from
solar cells and light emitting devices, to touch screens, photodetectors and
ultrafast lasers. Here we review the state of the art in this emerging field.Comment: Review Nature Photonics, in pres
Inter-basin transfers as a supply option: the end of an era?
International audienceThis chapter discusses the evolving role of interbasin transfers (IBT) in urban water management. After providing an historical overview of IBT development, the chapter describes how IBTs are challenged by a change in the technological and socio-economic context. The emergence of alternative technologies, such as desalination, wastewater reclamation and reuse, or managed artificial groundwater recharge is reducing the attractiveness of IBTs. Water utilities are also becoming increasingly aware that water conservation programs can save volumes of water at a much cheaper cost than IBT. Various international examples are used to show that IBTs trigger increasing concerns from communities involved or affected, in particular related to the environmental impact on donor and receiving river basins, the economic impact on donor regions, the impact on local cultures and livelihoods, how costs and benefits are distributed (social justice), and issues related to public participation. The chapter concludes by looking ahead at new and more efficient uses of existing IBTs. As conjunctive use management approaches gain support, IBTs will be operated in conjunction with aquifer storage and recovery schemes. They will probably also support the development of emerging water markets, in particular during drought years
Precision Top-Quark Mass Measurements at CDF
We present a precision measurement of the top-quark mass using the full
sample of Tevatron TeV proton-antiproton collisions collected
by the CDF II detector, corresponding to an integrated luminosity of 8.7
. Using a sample of candidate events decaying into the
lepton+jets channel, we obtain distributions of the top-quark masses and the
invariant mass of two jets from the boson decays from data. We then compare
these distributions to templates derived from signal and background samples to
extract the top-quark mass and the energy scale of the calorimeter jets with
{\it in situ} calibration. The likelihood fit of the templates from signal and
background events to the data yields the single most-precise measurement of the
top-quark mass, \mtop = 172.85 \pm\pmComment: submitted to Phys. Rev. Let
Evidence for t\bar{t}\gamma Production and Measurement of \sigma_t\bar{t}\gamma / \sigma_t\bar{t}
Using data corresponding to 6.0/fb of ppbar collisions at sqrt(s) = 1.96 TeV
collected by the CDF II detector, we present a cross section measurement of
top-quark pair production with an additional radiated photon. The events are
selected by looking for a lepton, a photon, significant transverse momentum
imbalance, large total transverse energy, and three or more jets, with at least
one identified as containing a b quark. The ttbar+photon sample requires the
photon to have 10 GeV or more of transverse energy, and to be in the central
region. Using an event selection optimized for the ttbar+photon candidate
sample we measure the production cross section of, and the ratio of cross
sections of the two samples. Control samples in the dilepton+photon and
lepton+photon+\met, channels are constructed to aid in decay product
identification and background measurements. We observe 30 ttbar+photon
candidate events compared to the standard model expectation of 26.9 +/- 3.4
events. We measure the ttbar+photon cross section to be 0.18+0.08 pb, and the
ratio of the cross section of ttbar+photon to ttbar to be 0.024 +/- 0.009.
Assuming no ttbar+photon production, we observe a probability of 0.0015 of the
background events alone producing 30 events or more, corresponding to 3.0
standard deviations.Comment: 9 pages, 3 figure
- …