313 research outputs found
Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease
BACKGROUND: The recent recognition that coronary-artery stenting has improved the short- and long-term outcomes of patients treated with angioplasty has made it necessary to reevaluate the relative benefits of bypass surgery and percutaneous interventions in patients with multivessel disease. METHODS: A total of 1205 patients were randomly assigned to undergo stent implantation or bypass surgery when a cardiac surgeon and an interventional cardiologist agreed that the same extent of revascularization could be achieved by either technique. The primary clinical end point was freedom from major adverse cardiac and cerebrovascular events at one year. The costs of hospital resources used were also determined. RESULTS: At one year, there was no significant difference between the two groups in terms of the rates of death, stroke, or myocardial infarction. Among patients who survived without a stroke or a myocardial infarction, 16.8 percent of those in the stenting group underwent a second revascularization, as compared with 3.5 percent of those in the surgery group. The rate of event-free survival at one year was 73.8 percent among the patients who received stents and 87.8 percent among those who underwent bypass surgery (P<0.001 by the log-rank test). The costs for the initial procedure were 2,973 per patient. CONCLUSION: As measured one year after the procedure, coronary stenting for multivessel disease is less expensive than bypass surgery and offers the same degree of protection against death, stroke, and myocardial infarction. However, stenting is associated with a greater need for repeated revascularization
SRAO CO Observation of 11 Supernova Remnants in l = 70 to 190 deg
We present the results of 12CO J = 1-0 line observations of eleven Galactic
supernova remnants (SNRs) obtained using the Seoul Radio Astronomy Observatory
(SRAO) 6-m radio telescope. The observation was made as a part of the SRAO CO
survey of SNRs between l = 70 and 190 deg, which is intended to identify SNRs
interacting with molecular clouds. The mapping areas for the individual SNRs
are determined to cover their full extent in the radio continuum. We used
halfbeam grid spacing (60") for 9 SNRs and full-beam grid spacing (120") for
the rest. We detected CO emission towards most of the remnants. In six SNRs,
molecular clouds showed a good spatial relation with their radio morphology,
although no direct evidence for the interaction was detected. Two SNRs are
particularly interesting: G85.4+0.7, where there is a filamentary molecular
cloud along the radio shell, and 3C434.1, where a large molecular cloud appears
to block the western half of the remnant. We briefly summarize the results
obtained for individual SNRs.Comment: Accepted for publication in Astrophysics & Space Science. 12 pages,
12 figures, and 3 table
ADAMTS13 and VWF activities guide individualized caplacizumab treatment in patients with aTTP
Introduction of the nanobody caplacizumab was shown to be effective in the treatment of acquired thrombotic thrombocytopenic purpura (aTTP) in the acute setting. The official recommendations include plasma exchange (PEX), immunosuppression, and the use of caplacizumab for a minimum of 30 days after stopping daily PEX. This study was a retrospective, observational analysis of the use of caplacizumab in 60 patients from 29 medical centers in Germany. Immunosuppressive treatment led to a rapid normalization of ADAMTS13 activities (calculated median, 21 days). In 35 of 60 patients, ADAMTS13 activities started to normalize before day 30 after PEX; in 11 of 60 patients, the treatment was extended beyond day 30; and in 5 patients, it was extended even beyond day 58 due to persistent autoimmune activity. In 34 of 60 instances, caplacizumab was stopped before day 30 with a favorable outcome whenever ADAMTS13 activities were >10%. In contrast, 11 of 34 patients with ADAMTS13 activities <10% at the time of stopping caplacizumab treatment developed a nonfavorable outcome (disease exacerbation or relapse). In some cases, prolongation of the treatment interval to every other day was feasible and resulted in a sustained reduction of von Willebrand factor activity. ADAMTS13 activity measurements are central for a rapid diagnosis in the acute setting but also to tailor disease management. An ADAMTS13 activity-guided approach seems safe for identifying the individual time point when to stop caplacizumab to prevent overtreatment and undertreatment; this approach will result in significant cost savings without jeopardizing the well-being of patients. In addition, von Willebrand factor activity may serve as a biomarker for drug monitoring
Measurement of the branching fraction
The branching fraction is measured in a data sample
corresponding to 0.41 of integrated luminosity collected with the LHCb
detector at the LHC. This channel is sensitive to the penguin contributions
affecting the sin2 measurement from The
time-integrated branching fraction is measured to be . This is the most precise measurement to
date
Real-world data confirm the effectiveness of caplacizumab in acquired thrombotic thrombocytopenic purpura
Acquired thrombotic thrombocytopenic purpura (aTTP) is a rare but life-threatening condition. In 2018, the nanobody caplacizumab was approved for the treatment of adults experiencing an acute episode of aTTP, in conjunction with plasma exchange (PEX) and immunosuppression for a minimum of 30 days after stopping daily PEX. We performed a retrospective, observational analysis on the use of caplacizumab in 60 patients from 29 medical centers in Germany during acute disease management. Caplacizumab led to a rapid normalization of the platelet count (median, 3 days; mean 3.78 days). One patient died after late treatment initiation due to aTTP-associated complications. In 2 patients with initial disease presentation and in 4 additional patients with laboratory signs of an exacerbation or relapse after the initial therapy, PEX-free treatment regimens could be established with overall favorable outcome. Caplacizumab is efficacious in the treatment of aTTP independent of timing and ancillary treatment modalities. Based on this real-world experience and published literature, we propose to administer caplacizumab immediately to all patients with an acute episode of aTTP. Treatment decisions regarding the use of PEX should be based on the severity of the clinical presentation and known risk factors. PEX might be dispensable in some patients
Model-independent search for CP violation in D0→K−K+π−π+ and D0→π−π+π+π− decays
A search for CP violation in the phase-space structures of D0 and View the MathML source decays to the final states K−K+π−π+ and π−π+π+π− is presented. The search is carried out with a data set corresponding to an integrated luminosity of 1.0 fb−1 collected in 2011 by the LHCb experiment in pp collisions at a centre-of-mass energy of 7 TeV. For the K−K+π−π+ final state, the four-body phase space is divided into 32 bins, each bin with approximately 1800 decays. The p-value under the hypothesis of no CP violation is 9.1%, and in no bin is a CP asymmetry greater than 6.5% observed. The phase space of the π−π+π+π− final state is partitioned into 128 bins, each bin with approximately 2500 decays. The p-value under the hypothesis of no CP violation is 41%, and in no bin is a CP asymmetry greater than 5.5% observed. All results are consistent with the hypothesis of no CP violation at the current sensitivity
Search for the lepton-flavor-violating decays Bs0→e±μ∓ and B0→e±μ∓
A search for the lepton-flavor-violating decays Bs0→e±μ∓ and B0→e±μ∓ is performed with a data sample, corresponding to an integrated luminosity of 1.0 fb-1 of pp collisions at √s=7 TeV, collected by the LHCb experiment. The observed number of Bs0→e±μ∓ and B0→e±μ∓ candidates is consistent with background expectations. Upper limits on the branching fractions of both decays are determined to be B(Bs0→e±μ∓)101 TeV/c2 and MLQ(B0→e±μ∓)>126 TeV/c2 at 95% C.L., and are a factor of 2 higher than the previous bounds
Absolute luminosity measurements with the LHCb detector at the LHC
Absolute luminosity measurements are of general interest for colliding-beam
experiments at storage rings. These measurements are necessary to determine the
absolute cross-sections of reaction processes and are valuable to quantify the
performance of the accelerator. Using data taken in 2010, LHCb has applied two
methods to determine the absolute scale of its luminosity measurements for
proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In
addition to the classic "van der Meer scan" method a novel technique has been
developed which makes use of direct imaging of the individual beams using
beam-gas and beam-beam interactions. This beam imaging method is made possible
by the high resolution of the LHCb vertex detector and the close proximity of
the detector to the beams, and allows beam parameters such as positions, angles
and widths to be determined. The results of the two methods have comparable
precision and are in good agreement. Combining the two methods, an overall
precision of 3.5% in the absolute luminosity determination is reached. The
techniques used to transport the absolute luminosity calibration to the full
2010 data-taking period are presented.Comment: 48 pages, 19 figures. Results unchanged, improved clarity of Table 6,
9 and 10 and corresponding explanation in the tex
Absolute luminosity measurements with the LHCb detector at the LHC
Absolute luminosity measurements are of general interest for colliding-beam
experiments at storage rings. These measurements are necessary to determine the
absolute cross-sections of reaction processes and are valuable to quantify the
performance of the accelerator. Using data taken in 2010, LHCb has applied two
methods to determine the absolute scale of its luminosity measurements for
proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In
addition to the classic "van der Meer scan" method a novel technique has been
developed which makes use of direct imaging of the individual beams using
beam-gas and beam-beam interactions. This beam imaging method is made possible
by the high resolution of the LHCb vertex detector and the close proximity of
the detector to the beams, and allows beam parameters such as positions, angles
and widths to be determined. The results of the two methods have comparable
precision and are in good agreement. Combining the two methods, an overall
precision of 3.5% in the absolute luminosity determination is reached. The
techniques used to transport the absolute luminosity calibration to the full
2010 data-taking period are presented.Comment: 48 pages, 19 figures. Results unchanged, improved clarity of Table 6,
9 and 10 and corresponding explanation in the tex
- …