12 research outputs found

    Effect of angiotensin-converting enzyme inhibitor and angiotensin receptor blocker initiation on organ support-free days in patients hospitalized with COVID-19

    Get PDF
    IMPORTANCE Overactivation of the renin-angiotensin system (RAS) may contribute to poor clinical outcomes in patients with COVID-19. Objective To determine whether angiotensin-converting enzyme (ACE) inhibitor or angiotensin receptor blocker (ARB) initiation improves outcomes in patients hospitalized for COVID-19. DESIGN, SETTING, AND PARTICIPANTS In an ongoing, adaptive platform randomized clinical trial, 721 critically ill and 58 non–critically ill hospitalized adults were randomized to receive an RAS inhibitor or control between March 16, 2021, and February 25, 2022, at 69 sites in 7 countries (final follow-up on June 1, 2022). INTERVENTIONS Patients were randomized to receive open-label initiation of an ACE inhibitor (n = 257), ARB (n = 248), ARB in combination with DMX-200 (a chemokine receptor-2 inhibitor; n = 10), or no RAS inhibitor (control; n = 264) for up to 10 days. MAIN OUTCOMES AND MEASURES The primary outcome was organ support–free days, a composite of hospital survival and days alive without cardiovascular or respiratory organ support through 21 days. The primary analysis was a bayesian cumulative logistic model. Odds ratios (ORs) greater than 1 represent improved outcomes. RESULTS On February 25, 2022, enrollment was discontinued due to safety concerns. Among 679 critically ill patients with available primary outcome data, the median age was 56 years and 239 participants (35.2%) were women. Median (IQR) organ support–free days among critically ill patients was 10 (–1 to 16) in the ACE inhibitor group (n = 231), 8 (–1 to 17) in the ARB group (n = 217), and 12 (0 to 17) in the control group (n = 231) (median adjusted odds ratios of 0.77 [95% bayesian credible interval, 0.58-1.06] for improvement for ACE inhibitor and 0.76 [95% credible interval, 0.56-1.05] for ARB compared with control). The posterior probabilities that ACE inhibitors and ARBs worsened organ support–free days compared with control were 94.9% and 95.4%, respectively. Hospital survival occurred in 166 of 231 critically ill participants (71.9%) in the ACE inhibitor group, 152 of 217 (70.0%) in the ARB group, and 182 of 231 (78.8%) in the control group (posterior probabilities that ACE inhibitor and ARB worsened hospital survival compared with control were 95.3% and 98.1%, respectively). CONCLUSIONS AND RELEVANCE In this trial, among critically ill adults with COVID-19, initiation of an ACE inhibitor or ARB did not improve, and likely worsened, clinical outcomes. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT0273570

    On the Failure of Total Ankle Replacement: A Retrieval Analysis

    No full text
    Total ankle replacement (TAR) has been under development for 40 years but is not considered as successful as other lower limb total joint replacements (TJR). The failure rate of TAR is more than double that of total hip replacement at 10 years, yet the failure mechanisms remain largely unknown. The research in this thesis aimed to identify the wear modes and possible origins of failure for a cohort of failed TARs using a retrieval analysis approach. Explants, medical imaging and periprosthetic tissue samples were retrieved for 44 participants following revision TAR surgery. Five TAR brands were retrieved, all of which were uncemented, three-component, mobile-bearing designs. Each resource was investigated using established and novel retrieval analysis methods including, but not limited to: photogrammetry, microscopy, non-contacting 3D surface profilometry, computed tomography and wear particle isolation. Ballooning osteolysis was highly prevalent. Component alignment was within alignment variations considered acceptable in the published literature, yet high rates of edge-loading (70.5%) and impingement (57%) were evident. Fixation and bearing surface wear affected 98% of tibial components. The volumetric wear rate for eight bearing inserts was 2.5 times higher than the greatest wear rate reported by in-vitro simulation studies. Hydroxyapatite wear particles were micron-sized with a high aspect ratio (AR = 3.7). Flake-like micron-sized cobalt chromium alloy and large titanium wear particles (>10 μm) were also isolated and characterised. The total wear particle population for TAR was generally larger and more elongated than the wear particle characteristics identified for other TJRs. Edge-loading, bearing insert subluxation and impingement contributed to wear modes 2, 3 and 4, which indicate device dysfunction and should be minimised by design. Mobile-bearing constraint, cortical window surgical approach and the rapid accrual of wear particles may be important contributors to the failure of TAR

    Continuous Improvement of Digital Health Applications Linked to Real-World Performance Monitoring: Safe Moving Targets?

    No full text
    Real-time high-quality data on the performance of digital health applications is needed for feedback-led optimization and to ensure safety and performance, particularly if they will have on-market updates. Developers must verify that applications accurately and consistently fulfill their intended purpose in real-world use. In particular, new thinking from regulators recognizes the importance of monitoring real-world performance. It is acknowledged that real-world data can deliver information from wider patient populations than are generally included in controlled studies, and in certain circumstances, this can enable extensions of the application’s intended purpose. Proactive postmarket surveillance surveys are an important source of real-world data that are distinct from clinical investigations but may vary in quality and, if inappropriately designed, can be subject to uncontrolled bias. We aimed to describe the practice of real-world data gathering through patient-reported and clinician-reported outcomes and high-quality surveys and identify challenges, uncertainties, and health policy gaps

    The revised Approved Instructional Resources score:An improved quality evaluation tool for online educational resources

    No full text
    BACKGROUND: Free Open-Access Medical education (FOAM) use among residents continues to rise. However, it often lacks quality assurance processes and residents receive little guidance on quality assessment. The Academic Life in Emergency Medicine Approved Instructional Resources tool (AAT) was created for FOAM appraisal by and for expert educators and has demonstrated validity in this context. It has yet to be evaluated in other populations.OBJECTIVES: We assessed the AAT's usability in a diverse population of practicing emergency medicine (EM) physicians, residents, and medical students; solicited feedback; and developed a revised tool.METHODS: As part of the Medical Education Translational Resources: Impact and Quality (METRIQ) study, we recruited medical students, EM residents, and EM attendings to evaluate five FOAM posts with the AAT and provide quantitative and qualitative feedback via an online survey. Two independent analysts performed a qualitative thematic analysis with discrepancies resolved through discussion and negotiated consensus. This analysis informed development of an initial revised AAT, which was then further refined after pilot testing among the author group. The final tool was reassessed for reliability.RESULTS: Of 330 recruited international participants, 309 completed all ratings. The Best Evidence in Emergency Medicine (BEEM) score was the component most frequently reported as difficult to use. Several themes emerged from the qualitative analysis: for ease of use-understandable, logically structured, concise, and aligned with educational value. Limitations include deviation from questionnaire best practices, validity concerns, and challenges assessing evidence-based medicine. Themes supporting its use include evaluative utility and usability. The author group pilot tested the initial revised AAT, revealing a total score average measure intraclass correlation coefficient (ICC) of moderate reliability (ICC = 0.68, 95% confidence interval [CI] = 0 to 0.962). The final AAT's average measure ICC was 0.88 (95% CI = 0.77 to 0.95).CONCLUSIONS: We developed the final revised AAT from usability feedback. The new score has significantly increased usability, but will need to be reassessed for reliability in a broad population.</p

    The Social Media Index as an Indicator of Quality for Emergency Medicine Blogs: A METRIQ Study

    No full text
    Study objective: Online educational resources such as blogs are increasingly used for education by emergency medicine clinicians. The Social Media Index was developed to quantify their relative impact. The Medical Education Translational Resources: Indicators of Quality (METRIQ) study was conducted in part to determine the association between the Social Media Index score and quality as measured by gestalt and previously derived quality instruments. Methods: Ten blogs were randomly selected from a list of emergency medicine and critical care Web sites. The 2 most recent clinically oriented blog posts published on these blogs were evaluated with gestalt, the Academic Life in Emergency Medicine Approved Instructional Resources (ALiEM AIR) score, and the METRIQ-8 score. Volunteer raters (including medical students, emergency medicine residents, and emergency medicine attending physicians) were identified with a multimodal recruitment methodology. The Social Media Index was calculated in February 2016, November 2016, April 2017, and December 2017. Pearson's correlations were calculated between the Social Media Index and the average rater gestalt, ALiEM AIR score, and METRIQ-8 score. Results: A total of 309 of 330 raters completed all ratings (93.6%). The Social Media Index correlated moderately to strongly with the mean rater gestalt ratings (range 0.69 to 0.76) and moderately with the mean rater ALiEM AIR score (range 0.55 to 0.61) and METRIQ-8 score (range 0.53 to 0.57) during the month of the blog post's selection and for 2 years after. Conclusion: The Social Media Index's correlation with multiple quality evaluation instruments over time supports the hypothesis that it is associated with overall Web site quality. It can play a role in guiding individuals to high-quality resources that can be reviewed with critical appraisal techniques

    Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years.

    Get PDF
    BACKGROUND: The erosion of the early mortality advantage of elective endovascular aneurysm repair (EVAR) compared with open repair of abdominal aortic aneurysm remains without a satisfactory explanation. METHODS: An individual-patient data meta-analysis of four multicentre randomized trials of EVAR versus open repair was conducted to a prespecified analysis plan, reporting on mortality, aneurysm-related mortality and reintervention. RESULTS: The analysis included 2783 patients, with 14 245 person-years of follow-up (median 5·5 years). Early (0-6 months after randomization) mortality was lower in the EVAR groups (46 of 1393 versus 73 of 1390 deaths; pooled hazard ratio 0·61, 95 per cent c.i. 0·42 to 0·89; P = 0·010), primarily because 30-day operative mortality was lower in the EVAR groups (16 deaths versus 40 for open repair; pooled odds ratio 0·40, 95 per cent c.i. 0·22 to 0·74). Later (within 3 years) the survival curves converged, remaining converged to 8 years. Beyond 3 years, aneurysm-related mortality was significantly higher in the EVAR groups (19 deaths versus 3 for open repair; pooled hazard ratio 5·16, 1·49 to 17·89; P = 0·010). Patients with moderate renal dysfunction or previous coronary artery disease had no early survival advantage under EVAR. Those with peripheral artery disease had lower mortality under open repair (39 deaths versus 62 for EVAR; P = 0·022) in the period from 6 months to 4 years after randomization. CONCLUSION: The early survival advantage in the EVAR group, and its subsequent erosion, were confirmed. Over 5 years, patients of marginal fitness had no early survival advantage from EVAR compared with open repair. Aneurysm-related mortality and patients with low ankle : brachial pressure index contributed to the erosion of the early survival advantage for the EVAR group. Trial registration numbers: EVAR-1, ISRCTN55703451; DREAM (Dutch Randomized Endovascular Aneurysm Management), NCT00421330; ACE (Anévrysme de l'aorte abdominale, Chirurgie versus Endoprothèse), NCT00224718; OVER (Open Versus Endovascular Repair Trial for Abdominal Aortic Aneurysms), NCT00094575

    Effect of Antiplatelet Therapy on Survival and Organ Support–Free Days in Critically Ill Patients With COVID-19

    No full text
    International audienc
    corecore