    Backflow air and pressure analysis in emptying a pipeline containing an entrapped air pocket

    Full text link
    [EN] The prediction of the pressure inside the air pocket in water pipelines has been the topic for a lot of research works. Several aspects in this field have been discussed, such as the filling and the emptying procedures. The emptying process can affect the safety and the efficiency of water systems. Current research presents an analysis of the emptying process using experimental and computational results. The phenomenon is simulated using the two-dimensional computational fluid dynamics (2D CFD) and the one-dimensional mathematical (1D) models. A backflow air analysis is also provided based on CFD simulations. The developed models show good ability in the prediction of the sub-atmospheric pressure and the flow velocity in the system. In most of the cases, the 1D and 2D CFD models show similar performance in the prediction of the pressure and the velocity results. The backflow air development can be accurately explained using the CFD model.This work was supported by the Fundação para a Ciência e a Tecnologia (FCT), Portugal under grant number PD/BD/114459/2016.Besharat, M.; Coronado-Hernández, OE.; Fuertes-Miquel, VS.; Viseu, MT.; Ramos, HM. (2018). Backflow air and pressure analysis in emptying a pipeline containing an entrapped air pocket. Urban Water Journal. 15(8):769-779. https://doi.org/10.1080/1573062X.2018.1540711S769779158Benjamin, T. B. (1968). Gravity currents and related phenomena. Journal of Fluid Mechanics, 31(2), 209-248. doi:10.1017/s0022112068000133Besharat, M., Teresa Viseu, M., & Ramos, H. (2017). Experimental Study of Air Vessel Behavior for Energy Storage or System Protection in Water Hammer Events. Water, 9(1), 63. doi:10.3390/w9010063Besharat, M., Tarinejad, R., & Ramos, H. M. (2015). The effect of water hammer on a confined air pocket towards flow energy storage system. Journal of Water Supply: Research and Technology-Aqua, 65(2), 116-126. doi:10.2166/aqua.2015.081Besharat, M., Tarinejad, R., Aalami, M. T., & Ramos, H. M. (2016). Study of a Compressed Air Vessel for Controlling the Pressure Surge in Water Networks: CFD and Experimental Analysis. Water Resources Management, 30(8), 2687-2702. doi:10.1007/s11269-016-1310-1Coronado-Hernández, O., Fuertes-Miquel, V., Besharat, M., & Ramos, H. (2017). Experimental and Numerical Analysis of a Water Emptying Pipeline Using Different Air Valves. Water, 9(2), 98. doi:10.3390/w9020098Coronado-Hernández, O. E., Fuertes-Miquel, V. S., Besharat, M., & Ramos, H. M. (2018). Subatmospheric pressure in a water draining pipeline with an air pocket. Urban Water Journal, 15(4), 346-352. doi:10.1080/1573062x.2018.1475578Edmunds, R. C. (1979). Air Binding in Pipes. Journal - American Water Works Association, 71(5), 272-277. doi:10.1002/j.1551-8833.1979.tb04348.xEscarameia, M. (2007). Investigating hydraulic removal of air from water pipelines. Proceedings of the Institution of Civil Engineers - Water Management, 160(1), 25-34. doi:10.1680/wama.2007.160.1.25Izquierdo, J., Fuertes, V. S., Cabrera, E., Iglesias, P. L., & Garcia-Serra, J. (1999). Pipeline start-up with entrapped air. Journal of Hydraulic Research, 37(5), 579-590. doi:10.1080/00221689909498518Kader, B. A. (1981). Temperature and concentration profiles in fully turbulent boundary layers. International Journal of Heat and Mass Transfer, 24(9), 1541-1544. doi:10.1016/0017-9310(81)90220-9Laanearu, J., Annus, I., Koppel, T., Bergant, A., Vučković, S., Hou, Q., … van’t Westende, J. M. C. (2012). Emptying of Large-Scale Pipeline by Pressurized Air. Journal of Hydraulic Engineering, 138(12), 1090-1100. doi:10.1061/(asce)hy.1943-7900.0000631Leon, A. S., Ghidaoui, M. S., Schmidt, A. R., & Garcia, M. H. (2010). A robust two-equation model for transient-mixed flows. Journal of Hydraulic Research, 48(1), 44-56. doi:10.1080/00221680903565911Martins, N. M. C., Delgado, J. N., Ramos, H. M., & Covas, D. I. C. (2017). Maximum transient pressures in a rapidly filling pipeline with entrapped air using a CFD model. Journal of Hydraulic Research, 55(4), 506-519. doi:10.1080/00221686.2016.1275046Martins, S. C., Ramos, H. M., & Almeida, A. B. (2015). Conceptual analogy for modelling entrapped air action in hydraulic systems. Journal of Hydraulic Research, 53(5), 678-686. doi:10.1080/00221686.2015.1077353Pozos, O., Gonzalez, C. A., Giesecke, J., Marx, W., & Rodal, E. A. (2010). Air entrapped in gravity pipeline systems. Journal of Hydraulic Research, 48(3), 338-347. doi:10.1080/00221686.2010.481839Ramezani, L., Karney, B., & Malekpour, A. (2016). Encouraging Effective Air Management in Water Pipelines: A Critical Review. Journal of Water Resources Planning and Management, 142(12), 04016055. doi:10.1061/(asce)wr.1943-5452.0000695Richards, R. T. (1962). Air Binding in Water Pipelines. Journal - American Water Works Association, 54(6), 719-730. doi:10.1002/j.1551-8833.1962.tb00883.xTijsseling, A. S., Hou, Q., Bozkuş, Z., & Laanearu, J. (2015). Improved One-Dimensional Models for Rapid Emptying and Filling of Pipelines. Journal of Pressure Vessel Technology, 138(3). doi:10.1115/1.4031508Triki, A. (2015). Water-hammer control in pressurized-pipe flow using an in-line polymeric short-section. Acta Mechanica, 227(3), 777-793. doi:10.1007/s00707-015-1493-1Vasconcelos, J. G., & Wright, S. J. (2008). Rapid Flow Startup in Filled Horizontal Pipelines. Journal of Hydraulic Engineering, 134(7), 984-992. doi:10.1061/(asce)0733-9429(2008)134:7(984)Wang, H., Zhou, L., Liu, D., Karney, B., Wang, P., Xia, L., … Xu, C. (2016). CFD Approach for Column Separation in Water Pipelines. Journal of Hydraulic Engineering, 142(10), 04016036. doi:10.1061/(asce)hy.1943-7900.0001171Zhou, F., Hicks, F. E., & Steffler, P. M. (2002). Transient Flow in a Rapidly Filling Horizontal Pipe Containing Trapped Air. Journal of Hydraulic Engineering, 128(6), 625-634. doi:10.1061/(asce)0733-9429(2002)128:6(625)Zhou, L., Liu, D., & Karney, B. (2013). Investigation of Hydraulic Transients of Two Entrapped Air Pockets in a Water Pipeline. Journal of Hydraulic Engineering, 139(9), 949-959. doi:10.1061/(asce)hy.1943-7900.0000750Zhou, L., Liu, D., & Ou, C. (2011). Simulation of Flow Transients in a Water Filling Pipe Containing Entrapped Air Pocket with VOF Model. Engineering Applications of Computational Fluid Mechanics, 5(1), 127-140. doi:10.1080/19942060.2011.11015357Zhou, L., Wang, H., Karney, B., Liu, D., Wang, P., & Guo, S. (2018). Dynamic Behavior of Entrapped Air Pocket in a Water Filling Pipeline. Journal of Hydraulic Engineering, 144(8), 04018045. doi:10.1061/(asce)hy.1943-7900.0001491Zukoski, E. E. (1966). Influence of viscosity, surface tension, and inclination angle on motion of long bubbles in closed tubes. Journal of Fluid Mechanics, 25(4), 821-837. doi:10.1017/s002211206600044

    DES study of blade trailing edge cutback cooling performance with various lip thicknesses

    Get PDF
    Three-dimensional detached-eddy simulation (DES) study has been carried out to evaluate the cooling performance of a trailing-edge cutback turbine blade with various lip thickness to slot height ratios (t/H). By adopting the shear-stress transport (SST) k-ω turbulence model, the numerical investigations were performed at two successive steps: first, to validate simulation results from an existing cutback turbine blade model with staggered circular pin-fins arrays inside the cooling passage against experimental measurements and other available numerical predictions; second, to understand the effects of the lip thickness to the slot height ratio on the blade trailing-edge cooling performance. It was found from the model validations that at two moderate blowing ratios of 0.5 and 1.1, DES predicted film cooling effectiveness are in very good agreement with experimental data. Further comparisons of four various t/H ratios (t/H = 0.25, 0.5, 1.0, 1.5) have revealed that the thermal mixing process between the ‘cold’ coolant gas and the ‘hot’ mainstream flow in the near wake region of the exit slot has been greatly intensified with the increase of the t/H ratio. As a result, it causes a rapid decay of the adiabatic film cooling effectiveness downstream of the blade trailing-edge. The observed vortex shedding and its characteristics in the near wake region are found to play an important role in determining the dynamic process of the ‘cold’ and the ‘warm’ airflow mixing, which in turn have significant influences on the prediction accuracy of the near-wall heat transfer performance. As the four t/H ratio increases from 0.25 to 1.5, DES predicts the decrease of main shedding frequencies as fs = 3.69, 3.2, 2.21, and 1.49 kHz, corresponding to Strouhal numbers St = 0.15, 0.20, 0.23, and 0.22, respectively. These results are in good agreement with available experimental measurements

    A study of the impact of building geometry on the thermal performance of road pavement solar collectors

    Get PDF
    Studies on RPSC (road pavement solar collectors) have shown the potential of reducing the UHI (urban heat island) effects by dissipating the heat from the pavement for energy harness. Several works have shown that the generated heat could be utilised for sustainable urban energy system. However, none of the previous literatures have assessed the effect of building geometry on the performance of the RPSC. This study investigates the thermal performance of an urban-integrated RPSC system by using CFD (computational fluid dynamic) simulation of integrated RPSC system with a standard urban canyon domain and an empty domain. Based on 21st June at 13:00, it was found that the RPSC system in urban canyon domain was on average 36.08% more effective in thermal collection and provided on average 27.11% more surface temperature reduction as compared to the RSPC application in rural/flat domain. The RPSC performance based on the effect from daily solar intensity was initiated with results demonstrated the efficiency of the RPSC in an urban setting was 7.14%–63.26% more than the rural/flat setting. Simulations of various wind speeds in summer day(s) and the impact of seasonal changes to the RPSC system were also conducted to investigate the deficiency factors to the system

    Investigation into air distribution systems and thermal environment control in chilled food processing facilities

    Get PDF
    Air flow distribution in chilled food facilities plays a critical role not only in maintaining the required food products temperature but also because of its impact on the facility energy consumption and CO2 emissions. This paper presents an investigation of the thermal environment in existing food manufacturing facilities, with different air distribution systems including supply/return diffusers and fabric ducts, by means of both in-situ measurements and 3D CFD simulations. Measurements and CFD simulations showed that the fabric duct provides a better environment in the processing area in terms of even and low air flow if compared to that with the diffusers. Moreover, temperature stratification was identified as a key factor to be improved to reduce the energy use for the space cooling. Further modelling proved that air temperature stratification improves by relocating the fabric ducts at a medium level. This resulted in a temperature gradient increase up to 4.1 °C in the unoccupied zone