233 research outputs found

    Nonrigid reconstruction of 3D breast surfaces with a low-cost RGBD camera for surgical planning and aesthetic evaluation

    Get PDF
    Accounting for 26% of all new cancer cases worldwide, breast cancer remains the most common form of cancer in women. Although early breast cancer has a favourable long-term prognosis, roughly a third of patients suffer from a suboptimal aesthetic outcome despite breast conserving cancer treatment. Clinical-quality 3D modelling of the breast surface therefore assumes an increasingly important role in advancing treatment planning, prediction and evaluation of breast cosmesis. Yet, existing 3D torso scanners are expensive and either infrastructure-heavy or subject to motion artefacts. In this paper we employ a single consumer-grade RGBD camera with an ICP-based registration approach to jointly align all points from a sequence of depth images non-rigidly. Subtle body deformation due to postural sway and respiration is successfully mitigated leading to a higher geometric accuracy through regularised locally affine transformations. We present results from 6 clinical cases where our method compares well with the gold standard and outperforms a previous approach. We show that our method produces better reconstructions qualitatively by visual assessment and quantitatively by consistently obtaining lower landmark error scores and yielding more accurate breast volume estimates

    Towards markerless orthopaedic navigation with intuitive Optical See-through Head-mounted displays

    Get PDF
    The potential of image-guided orthopaedic navigation to improve surgical outcomes has been well-recognised during the last two decades. According to the tracked pose of target bone, the anatomical information and preoperative plans are updated and displayed to surgeons, so that they can follow the guidance to reach the goal with higher accuracy, efficiency and reproducibility. Despite their success, current orthopaedic navigation systems have two main limitations: for target tracking, artificial markers have to be drilled into the bone and calibrated manually to the bone, which introduces the risk of additional harm to patients and increases operating complexity; for guidance visualisation, surgeons have to shift their attention from the patient to an external 2D monitor, which is disruptive and can be mentally stressful. Motivated by these limitations, this thesis explores the development of an intuitive, compact and reliable navigation system for orthopaedic surgery. To this end, conventional marker-based tracking is replaced by a novel markerless tracking algorithm, and the 2D display is replaced by a 3D holographic Optical see-through (OST) Head-mounted display (HMD) precisely calibrated to a user's perspective. Our markerless tracking, facilitated by a commercial RGBD camera, is achieved through deep learning-based bone segmentation followed by real-time pose registration. For robust segmentation, a new network is designed and efficiently augmented by a synthetic dataset. Our segmentation network outperforms the state-of-the-art regarding occlusion-robustness, device-agnostic behaviour, and target generalisability. For reliable pose registration, a novel Bounded Iterative Closest Point (BICP) workflow is proposed. The improved markerless tracking can achieve a clinically acceptable error of 0.95 deg and 2.17 mm according to a phantom test. OST displays allow ubiquitous enrichment of perceived real world with contextually blended virtual aids through semi-transparent glasses. They have been recognised as a suitable visual tool for surgical assistance, since they do not hinder the surgeon's natural eyesight and require no attention shift or perspective conversion. The OST calibration is crucial to ensure locational-coherent surgical guidance. Current calibration methods are either human error-prone or hardly applicable to commercial devices. To this end, we propose an offline camera-based calibration method that is highly accurate yet easy to implement in commercial products, and an online alignment-based refinement that is user-centric and robust against user error. The proposed methods are proven to be superior to other similar State-of- the-art (SOTA)s regarding calibration convenience and display accuracy. Motivated by the ambition to develop the world's first markerless OST navigation system, we integrated the developed markerless tracking and calibration scheme into a complete navigation workflow designed for femur drilling tasks during knee replacement surgery. We verify the usability of our designed OST system with an experienced orthopaedic surgeon by a cadaver study. Our test validates the potential of the proposed markerless navigation system for surgical assistance, although further improvement is required for clinical acceptance.Open Acces

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Augmented reality in open surgery

    Get PDF
    Augmented reality (AR) has been successfully providing surgeons an extensive visual information of surgical anatomy to assist them throughout the procedure. AR allows surgeons to view surgical field through the superimposed 3D virtual model of anatomical details. However, open surgery presents new challenges. This study provides a comprehensive overview of the available literature regarding the use of AR in open surgery, both in clinical and simulated settings. In this way, we aim to analyze the current trends and solutions to help developers and end/users discuss and understand benefits and shortcomings of these systems in open surgery. We performed a PubMed search of the available literature updated to January 2018 using the terms (1) “augmented reality” AND “open surgery”, (2) “augmented reality” AND “surgery” NOT “laparoscopic” NOT “laparoscope” NOT “robotic”, (3) “mixed reality” AND “open surgery”, (4) “mixed reality” AND “surgery” NOT “laparoscopic” NOT “laparoscope” NOT “robotic”. The aspects evaluated were the following: real data source, virtual data source, visualization processing modality, tracking modality, registration technique, and AR display type. The initial search yielded 502 studies. After removing the duplicates and by reading abstracts, a total of 13 relevant studies were chosen. In 1 out of 13 studies, in vitro experiments were performed, while the rest of the studies were carried out in a clinical setting including pancreatic, hepatobiliary, and urogenital surgeries. AR system in open surgery appears as a versatile and reliable tool in the operating room. However, some technological limitations need to be addressed before implementing it into the routine practice

    Robotic Implant Modification for Neuroplastic Surgery

    Get PDF
    Neuroplastic surgery, which combines neurosurgery with plastic surgery, is a novel field that has not been rigorously studied. It has crucial clinical potentials in implanting instrumented devices for brain imaging, targeted drug delivery, deep brain stimulation, shunt placement, and so on. A specific application of neuroplastic surgery is single-stage cranioplasty. Current practice involves resizing a prefabricated oversized customized cranial implant (CCI). This method provides intraoperative flexibility for skull resection. However, surgeons need to manually resize the CCI to fit the craniofacial bone defect based on their judgment and estimation. This manual modification can be time-consuming and imprecise, resulting in large bone gaps between the skull and the resized implant. This work investigates the possibility of applying robotic and computer-integrated techniques to improve the procedure. This dissertation describes the development and examination of several systems to address the challenges that emerged from the CCI resizing process: (i) To assist the manual modification, a portable projection mapping device (PPMD) provides precise real-time visual guidance for surgeons to outline the defect boundary on the oversized CCI. (ii) Even with the assistance of a projection system, the subsequent manual resizing may still be imprecise and prone to failure. This work introduces an automated workflow for intraoperative CCI modification using a robotic system. (iii) A 2-scan method accomplishes the patient-to-CT registration using a handheld 3D scanner and addresses the challenges posed by the soft tissues and the surgical draping requirement using reattachable fiducial markers. (iv) A toolpath algorithm generates a cutting toolpath for the robot to resize the implant based on the defect geometry. (v) Due to certain limitations associated with mechanical cutting, this work presents a 5-axis CO\textsubscript{2} laser cutting system that achieves fast and precise implant modification, ideal for fabricating instrumented implants. The evaluation of the automated workflow shows a significant improvement in CCI resizing accuracy. This indicates lower risk of implant failure causing post-surgical complications. Furthermore, the functions provided by these systems can be expanded to other neuroplastic applications

    Recent Advancements in Augmented Reality for Robotic Applications: A Survey

    Get PDF
    Robots are expanding from industrial applications to daily life, in areas such as medical robotics, rehabilitative robotics, social robotics, and mobile/aerial robotics systems. In recent years, augmented reality (AR) has been integrated into many robotic applications, including medical, industrial, human–robot interactions, and collaboration scenarios. In this work, AR for both medical and industrial robot applications is reviewed and summarized. For medical robot applications, we investigated the integration of AR in (1) preoperative and surgical task planning; (2) image-guided robotic surgery; (3) surgical training and simulation; and (4) telesurgery. AR for industrial scenarios is reviewed in (1) human–robot interactions and collaborations; (2) path planning and task allocation; (3) training and simulation; and (4) teleoperation control/assistance. In addition, the limitations and challenges are discussed. Overall, this article serves as a valuable resource for working in the field of AR and robotic research, offering insights into the recent state of the art and prospects for improvement

    Review on Augmented Reality in Oral and Cranio-Maxillofacial Surgery: Toward 'Surgery-Specific' Head-Up Displays

    Get PDF
    In recent years, there has been an increasing interest towards the augmented reality as applied to the surgical field. We conducted a systematic review of literature classifying the augmented reality applications in oral and cranio-maxillofacial surgery (OCMS) in order to pave the way to future solutions that may ease the adoption of AR guidance in surgical practice. Publications containing the terms 'augmented reality' AND 'maxillofacial surgery', and the terms 'augmented reality' AND 'oral surgery' were searched in the PubMed database. Through the selected studies, we performed a preliminary breakdown according to general aspects, such as surgical subspecialty, year of publication and country of research; then, a more specific breakdown was provided according to technical features of AR-based devices, such as virtual data source, visualization processing mode, tracking mode, registration technique and AR display type. The systematic search identified 30 eligible publications. Most studies (14) were in orthognatic surgery, the minority (2) concerned traumatology, while 6 studies were in oncology and 8 in general OCMS. In 8 of 30 studies the AR systems were based on a head-mounted approach using smart glasses or headsets. In most of these cases (7), a video-see-through mode was implemented, while only 1 study described an optical-see-through mode. In the remaining 22 studies, the AR content was displayed on 2D displays (10), full-parallax 3D displays (6) and projectors (5). In 1 case the AR display type is not specified. AR applications are of increasing interest and adoption in oral and cranio-maxillofacial surgery, however, the quality of the AR experience represents the key requisite for a successful result. Widespread use of AR systems in the operating room may be encouraged by the availability of 'surgery-specific' head-mounted devices that should guarantee the accuracy required for surgical tasks and the optimal ergonomics

    Nonrigid reconstruction of 3D breast surfaces with a low-cost RGBD camera for surgical planning and aesthetic evaluation

    Get PDF
    Accounting for 26% of all new cancer cases worldwide, breast cancer remains the most common form of cancer in women. Although early breast cancer has a favourable long-term prognosis, roughly a third of patients suffer from a suboptimal aesthetic outcome despite breast conserving cancer treatment. Clinical-quality 3D modelling of the breast surface therefore assumes an increasingly important role in advancing treatment planning, prediction and evaluation of breast cosmesis. Yet, existing 3D torso scanners are expensive and either infrastructure-heavy or subject to motion artefacts. In this paper we employ a single consumer-grade RGBD camera with an ICP-based registration approach to jointly align all points from a sequence of depth images non-rigidly. Subtle body deformation due to postural sway and respiration is successfully mitigated leading to a higher geometric accuracy through regularised locally affine transformations. We present results from 6 clinical cases where our method compares well with the gold standard and outperforms a previous approach. We show that our method produces better reconstructions qualitatively by visual assessment and quantitatively by consistently obtaining lower landmark error scores and yielding more accurate breast volume estimates
    corecore