309 research outputs found

    Does higher sampling rate (multiband + SENSE) improve group statistics - An example from social neuroscience block design at 3T

    Get PDF
    Multiband (MB) or Simultaneous multi-slice (SMS) acquisition schemes allow the acquisition of MRI signals from more than one spatial coordinate at a time. Commercial availability has brought this technique within the reach of many neuroscientists and psychologists. Most early evaluation of the performance of MB acquisition employed resting state fMRI or the most basic tasks. In this study, we tested whether the advantages of using MB acquisition schemes generalize to group analyses using a cognitive task more representative of typical cognitive neuroscience applications. Twenty-three subjects were scanned on a Philips 3 ​T scanner using five sequences, up to eight-fold acceleration with MB-factors 1 to 4, SENSE factors up to 2 and corresponding TRs of 2.45s down to 0.63s, while they viewed (i) movie blocks showing complex actions with hand object interactions and (ii) control movie blocks without hand object interaction. Data were processed using a widely used analysis pipeline implemented in SPM12 including the unified segmentation and canonical HRF modelling. Using random effects group-level, voxel-wise analysis we found that all sequences were able to detect the basic action observation network known to be recruited by our task. The highest t-values were found for sequences with MB4 acceleration. For the MB1 sequence, a 50% bigger voxel volume was needed to reach comparable t-statistics. The group-level t-values for resting state networks (RSNs) were also highest for MB4 sequences. Here the MB1 sequence with larger voxel size did not perform comparable to the MB4 sequence. Altogether, we can thus recommend the use of MB4 (and SENSE 1.5 or 2) on a Philips scanner when aiming to perform group-level analyses using cognitive block design fMRI tasks and voxel sizes in the range of cortical thickness (e.g. 2.7 ​mm isotropic). While results will not be dramatically changed by the use of multiband, our results suggest that MB will bring a moderate but significant benefit

    Impacts of Simultaneous Multislice Acquisition on Sensitivity and Specificity in fMRI

    Get PDF
    Simultaneous multislice (SMS) imaging can be used to decrease the time between acquisition of fMRI volumes, which can increase sensitivity by facilitating the removal of higher-frequency artifacts and boosting effective sample size. The technique requires an additional processing step in which the slices are separated, or unaliased, to recover the whole brain volume. However, this may result in signal “leakage” between aliased locations, i.e., slice “leakage,” and lead to spurious activation (decreased specificity). SMS can also lead to noise amplification, which can reduce the benefits of decreased repetition time. In this study, we evaluate the original slice-GRAPPA (no leak block) reconstruction algorithmand acceleration factor (AF = 8) used in the fMRI data in the young adult Human Connectome Project (HCP). We also evaluate split slice-GRAPPA (leak block), which can reduce slice leakage. We use simulations to disentangle higher test statistics into true positives (sensitivity) and false positives (decreased specificity). Slice leakage was greatly decreased by split slice-GRAPPA. Noise amplification was decreased by using moderate acceleration factors (AF = 4). We examined slice leakage in unprocessed fMRI motor task data from the HCP. When data were smoothed, we found evidence of slice leakage in some, but not all, subjects. We also found evidence of SMS noise amplification in unprocessed task and processed resting-state HCP data

    Functional Magnetic Resonance Imaging at High Spatiotemporal Resolution using EPI Combined with Different k-Space Undersampling Techniques at 3 Tesla

    Get PDF
    In functional magnetic resonance imaging (fMRI), major drawbacks of the commonly used echo-planar imaging (EPI) sequence are limited spatial specificity due to blurring and distortions as well as signal cancellation in areas affected by susceptibility gradients, such as the orbitofrontal cortex (OFC). In contrast, segmented EPI techniques facilitate ultra-high spatial but low temporal resolution. In this work, an EPI sequence with optimized slice-dependent echo time was developed avoiding signal drop outs in the OFC in 50 % of all subjects during fMRI (N = 12) compared to a standard EPI sequence. The average number of activated voxels detected in the OFC was thereby increased by a factor of 6.3. It was further shown for the first time that the spatial specificity in EPI fMRI at 3 T can be improved by increasing the matrix size in combination with the parallel imaging factor beyond conventional EPI parameter settings. By using the proposed high-resolution compared to a standard EPI protocol, the multi-subject analysis of a simple fingertapping task (N = 6) and a sophisticated motivation task (N = 15) showed robust and clearly less blurred activation in the sensorimotor cortex (SMC) and in the nucleus accumbens (NAcc), respectively. The number of separable clusters detected in the SMC and in the NAcc was thereby increased by a factor of 2.7 and 1.4, respectively. In order to perform fMRI at ultra-high spatial and high temporal resolution, a segmented EPI sequence was highly accelerated (R = 8) with the so-called UNFOLD technique. Both, the MR sequence and data post-processing were optimized facilitating the robust detection of neuronal activation at 0.7 x 0.7 mm2 resolution and half-brain coverage. Last but not least, a novel filtering strategy is proposed minimizing temporal coherences in UNFOLD datasets and thus improving the detectability of neuronal activation. By using the proposed filter compared to a standard filter, the number of activated voxels detected in the SMC (N = 5) was increased up to a factor of 1.4

    Phase imaging for reducing macrovascular signal contributions in high-resolution fMRI

    Get PDF
    High resolution functional MRI allows for the investigation of neural activity within the cortical sheet. One consideration in high resolution fMRI is the choice of which sequence to use during imaging, as all methods come with sensitivity and specificity tradeoffs. The most used fMRI sequence is gradient-echo echo planar imaging (GE-EPI) which has the highest sensitivity but is not specific to microvasculature. GE-EPI results in a signal with pial vessel bias which increases complexity of performing studies targeted at structures within the cortex. This work seeks to explore the use of MRI phase signal as a macrovascular filter to correct this bias. First, an in-house phase combination method was designed and tested on the 7T MRI system. This method, the fitted SVD method, uses a low-resolution singular value decomposition and fitting to a polynomial basis to provide computationally efficient, phase sensitive, coil combination that is insensitive to motion. Second, a direct comparison of GE-EPI, GE-EPI with phase regression (GE-EPI-PR), and spin echo EPI (SE-EPI) was performed in humans completing a visual task. The GE-EPI-PR activation showed higher spatial similarity with SE-EPI than GE-EPI across the cortical surface. GE-EPI-PR produced a similar laminar profile to SE-EPI while maintaining a higher contrast-to-noise ratio across layers, making it a useful method in low SNR studies such as high-resolution fMRI. The final study extended this work to a resting state macaque experiment. Macaques are a common model for laminar fMRI as they allow for simultaneous imaging and electrophysiology. We hypothesized that phase regression could improve spatial specificity of the resting state data. Further analysis showed the phase data contained both system and respiratory artifacts which prevented the technique performing as expected under two physiological cleaning strategies. Future work will have to examine on-scanner physiology correction to obtain a phase timeseries without artifacts to allow for the phase regression technique to be used in macaques. This work demonstrates that phase regression reduces signal contributions from pial vessels and will improve specificity in human layer fMRI studies. This method can be completed easily with complex fMRI data which can be created using our fitted SVD method

    Serial Correlations in Single-Subject fMRI with Sub-Second TR

    Full text link
    When performing statistical analysis of single-subject fMRI data, serial correlations need to be taken into account to allow for valid inference. Otherwise, the variability in the parameter estimates might be under-estimated resulting in increased false-positive rates. Serial correlations in fMRI data are commonly characterized in terms of a first-order autoregressive (AR) process and then removed via pre-whitening. The required noise model for the pre-whitening depends on a number of parameters, particularly the repetition time (TR). Here we investigate how the sub-second temporal resolution provided by simultaneous multislice (SMS) imaging changes the noise structure in fMRI time series. We fit a higher-order AR model and then estimate the optimal AR model order for a sequence with a TR of less than 600 ms providing whole brain coverage. We show that physiological noise modelling successfully reduces the required AR model order, but remaining serial correlations necessitate an advanced noise model. We conclude that commonly used noise models, such as the AR(1) model, are inadequate for modelling serial correlations in fMRI using sub-second TRs. Rather, physiological noise modelling in combination with advanced pre-whitening schemes enable valid inference in single-subject analysis using fast fMRI sequences

    The Human Connectome Project's neuroimaging approach

    Get PDF
    Noninvasive human neuroimaging has yielded many discoveries about the brain. Numerous methodological advances have also occurred, though inertia has slowed their adoption. This paper presents an integrated approach to data acquisition, analysis and sharing that builds upon recent advances, particularly from the Human Connectome Project (HCP). The 'HCP-style' paradigm has seven core tenets: (i) collect multimodal imaging data from many subjects; (ii) acquire data at high spatial and temporal resolution; (iii) preprocess data to minimize distortions, blurring and temporal artifacts; (iv) represent data using the natural geometry of cortical and subcortical structures; (v) accurately align corresponding brain areas across subjects and studies; (vi) analyze data using neurobiologically accurate brain parcellations; and (vii) share published data via user-friendly databases. We illustrate the HCP-style paradigm using existing HCP data sets and provide guidance for future research. Widespread adoption of this paradigm should accelerate progress in understanding the brain in health and disease
    • …
    corecore