342 research outputs found

    Monitoring muscle fatigue following continuous load changes

    Get PDF
    Department of Human Factors EngineeringPrevious studies related to monitoring muscle fatigue during dynamic motion have focused on detecting the accumulation of muscle fatigue. However, it is necessary to detect both accumulation and recovery of muscle fatigue in dynamic muscle contraction while muscle load changes continuously. This study aims to investigate the development and recovery of muscle fatigue in dynamic muscle contraction conditions following continuous load changes. Twenty healthy males conducted repetitive elbow flexion and extension using 2kg and 1kg dumbbell, by turns. They performed the two tasks of different intensity (2kg intensity task, 1kg intensity task) alternately until they felt they could no longer achieve the required movement range or until they experienced unacceptable biceps muscle discomfort. Meanwhile, using EMG signal of biceps brachii muscle, fatigue detections were performed from both dynamic measurements during each dynamic muscle contraction task and isometric measurements during isometric muscle contraction right before and after each task. In each of 2kg and 1kg intensity tasks, pre, post and change value of EMG amplitude (AEMG) and center frequency were computed respectively. They were compared to check the validity of the muscle fatigue monitoring method using Wavelet transform with EMG signal from dynamic measurements. As a result, a decrease of center frequency in 2kg intensity tasks and an increase of center frequency in 1kg intensity tasks were detected. It shows that development and recovery of muscle fatigue were detected in 2kg and 1kg intensity tasks, respectively. Also, the tendency of change value of center frequency from dynamic measurements were corresponded with that from isometric measurements. It suggests that monitoring muscle fatigue in dynamic muscle contraction conditions using wavelet transform was valid to detect the development and recovery of muscle fatigue continuously. The result also shows the possibility of monitoring muscle fatigue in real-time in industry and it could propose a guideline in designing a human-robot interaction system based on monitoring user's muscle fatigue.clos

    Discrete Wavelet Transform Analysis of Surface Electromyography for the Objective Assessment of Neck and Shoulder Muscle Fatigue

    Get PDF
    Objective assessment of neuromuscular fatigue caused by sub-maximal repetitive exertions is essential for the early detection and prevention of risks of neck and shoulder musculoskeletal disorders. In recent years, discrete wavelet transforms (DWT) of surface electromyography (SEMG) has been used to evaluate muscle fatigue, especially during dynamic contractions when the SEMG signal is non-stationary. However, its application to neck muscle fatigue assessment is not well established. Therefore, the purpose of this study was to establish DWT analysis as a suitable method to conduct quantitative assessment of neck muscle fatigue caused by dynamic exertions. Ten human participants performed 40 minutes of fatiguing repetitive arm and neck exertions. SEMG data from the upper trapezius and sternocleidomastoid muscles were recorded. Ten most commonly used orthogonal wavelet functions were used to conduct DWT analysis. A significant increase in the power was observed at lower frequency bands of 6-12Hz, 12-23 Hz, and 23-46 Hz with the onset and development of fatigue for most of the wavelet functions. Among ten wavelet function, a relatively higher power estimation, consistent statistical trend and better power contrast with the onset and development of fatigue was observed for the Rbio3.1 wavelet function. The results of this study will assist Professional Ergonomists to automate the process of localized muscle fatigue estimation, which could have applications related to improving working environment

    Techniques of EMG signal analysis: detection, processing, classification and applications

    Get PDF
    Electromyography (EMG) signals can be used for clinical/biomedical applications, Evolvable Hardware Chip (EHW) development, and modern human computer interaction. EMG signals acquired from muscles require advanced methods for detection, decomposition, processing, and classification. The purpose of this paper is to illustrate the various methodologies and algorithms for EMG signal analysis to provide efficient and effective ways of understanding the signal and its nature. We further point up some of the hardware implementations using EMG focusing on applications related to prosthetic hand control, grasp recognition, and human computer interaction. A comparison study is also given to show performance of various EMG signal analysis methods. This paper provides researchers a good understanding of EMG signal and its analysis procedures. This knowledge will help them develop more powerful, flexible, and efficient applications

    Current state of digital signal processing in myoelectric interfaces and related applications

    Get PDF
    This review discusses the critical issues and recommended practices from the perspective of myoelectric interfaces. The major benefits and challenges of myoelectric interfaces are evaluated. The article aims to fill gaps left by previous reviews and identify avenues for future research. Recommendations are given, for example, for electrode placement, sampling rate, segmentation, and classifiers. Four groups of applications where myoelectric interfaces have been adopted are identified: assistive technology, rehabilitation technology, input devices, and silent speech interfaces. The state-of-the-art applications in each of these groups are presented.Peer reviewe

    Novel Pseudo-Wavelet function for MMG signal extraction during dynamic fatiguing contractions

    Get PDF
    The purpose of this study was to develop an algorithm to classify muscle fatigue content in sports related scenarios. Mechanomyography (MMG) signals of the biceps muscle were recorded from thirteen subjects performing dynamic contractions until fatigue. For training and testing purposes, the signals were labeled in two classes (Non-Fatigue and Fatigue). A genetic algorithm was used to evolve a pseudo-wavelet function for optimizing the detection of muscle fatigue. Tuning of the generalized evolved pseudo-wavelet function was based on the decomposition of 70% of the conducted MMG trials. After completing 25 independent pseudo-wavelet evolution runs, the best run was selected and then tested on the remaining 30% of the data to measure the classification performance. Results show that the evolved pseudo-wavelet improved the classification rate of muscle fatigue by 4.70 percentage points to 16.61 percentage points when compared to other standard wavelet functions, giving an average correct classification of 80.63%, with statistical significance (p < 0.05). © 2014 by the authors; licensee MDPI, Basel, Switzerland

    A Weak Monotonicity Based Muscle Fatigue Detection Algorithm for a Short-Duration Poor Posture Using sEMG Measurements

    Full text link
    Muscle fatigue is usually defined as a decrease in the ability to produce force. The surface electromyography (sEMG) signals have been widely used to provide information about muscle activities including detecting muscle fatigue by various data-driven techniques such as machine learning and statistical approaches. However, it is well-known that sEMG signals are weak signals (low amplitude of the signals) with a low signal-to-noise ratio, data-driven techniques cannot work well when the quality of the data is poor. In particular, the existing methods are unable to detect muscle fatigue coming from static poses. This work exploits the concept of weak monotonicity, which has been observed in the process of fatigue, to robustly detect muscle fatigue in the presence of measurement noises and human variations. Such a population trend methodology has shown its potential in muscle fatigue detection as demonstrated by the experiment of a static pose.Comment: 4 pages, 4 figures. This work has been submitted to the IEEE EMBC for possible publicatio

    A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue

    Get PDF
    Muscle fatigue is an established area of research and various types of muscle fatigue have been investigated in order to fully understand the condition. This paper gives an overview of the various non-invasive techniques available for use in automated fatigue detection, such as mechanomyography, electromyography, near-infrared spectroscopy and ultrasound for both isometric and non-isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who wish to select the most appropriate methodology for research on muscle fatigue detection or prediction, or for the development of devices that can be used in, e.g., sports scenarios to improve performance or prevent injury. To date, research on localised muscle fatigue focuses mainly on the clinical side. There is very little research carried out on the implementation of detecting/predicting fatigue using an autonomous system, although recent research on automating the process of localised muscle fatigue detection/prediction shows promising results
    corecore