477 research outputs found
KATANA - a charge-sensitive triggering system for the SRIT experiment
KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has
been built and used as a trigger and veto detector for the SRIT TPC at
RIKEN. Its construction allows operating in magnetic field and providing fast
response for ionizing particles, giving the approximate forward multiplicity
and charge information. Depending on this information, trigger and veto signals
are generated. The article presents performance of the detector and details of
its construction. A simple phenomenological parametrization of the number of
emitted scintillation photons in plastic scintillator is proposed. The effect
of the light output deterioration in the plastic scintillator due to the
in-beam irradiation is discussed.Comment: 14 pages, 11 figure
Quantitative reduction of RyR1 protein caused by a single-allele frameshift mutation in RYR1 ex36 impairs the strength of adult skeletal muscle fibres
Here we characterized a mouse model knocked-in for a frameshift mutation in RYR1 exon 36 (p.Gln1970fsX16) that is isogenic to that identified in one parent of a severely affected patient with recessively inherited multiminicore disease. This individual carrying the RYR1 frameshifting mutation complained of mild muscle weakness and fatigability. Analysis of the RyR1 protein content in a muscle biopsy from this individual showed a content of only 20% of that present in a control individual. The biochemical and physiological characteristics of skeletal muscles from RyR1Q1970fsX16 heterozygous mice recapitulates that of the heterozygous parent. RyR1 protein content in the muscles of mutant mice reached 38% and 58% of that present in total muscle homogenates of fast and slow muscles from wild-type (WT) littermates. The decrease of RyR1 protein content in total homogenates is not accompanied by a decrease of Cav1.1 content, whereby the Cav1.1/RyR1 stoichiometry ratio in skeletal muscles from RyR1Q1970fsX16 heterozygous mice is lower compared to that from WT mice. Electron microscopy (EM) revealed a 36% reduction in the number/area of calcium release units accompanied by a 2.5-fold increase of dyads (triads that have lost one junctional sarcoplasmic reticulum element); both results suggest a reduction of the RyR1 arrays. Compared to WT, muscle strength and depolarization-induced calcium transients in RyR1Q1970fsX16 heterozygous mice muscles were decreased by 20% and 15%, respectively. The RyR1Q1970fsX16 mouse model provides mechanistic insight concerning the phenotype of the parent carrying the RYR1 ex36 mutation and suggests that in skeletal muscle fibres there is a functional reserve of RyR1
A novel experimental setup for rare events selection and its potential application to super-heavy elements search
The paper presents a novel instrumentation for rare events selection which was tested in our research of short-lived super-heavy elements production and detection. The instrumentation includes an active catcher multi-elements system and dedicated electronics. The active catcher located in the forward hemisphere is composed of 63 scintillator detection modules. Reaction products of damped collisions between heavy-ion projectiles and heavy-target nuclei are implanted in the fast plastic scintillators of the active catcher modules. The acquisition system trigger delivered by logical branch of the electronics allows to record the reaction products which decay via the alpha-particle emissions or spontaneous fission which take place between beam bursts. One microsecond wave form signal from FADCs contains information on heavy implanted nucleus as well as its decays
The first search for bosonic super-WIMPs with masses up to 1 MeV/c with GERDA
We present the first search for bosonic super-WIMPs as keV-scale dark matter
candidates performed with the GERDA experiment. GERDA is a neutrinoless
double-beta decay experiment which operates high-purity germanium detectors
enriched in Ge in an ultra-low background environment at the Laboratori
Nazionali del Gran Sasso (LNGS) of INFN in Italy. Searches were performed for
pseudoscalar and vector particles in the mass region from 60 keV/c to 1
MeV/c. No evidence for a dark matter signal was observed, and the most
stringent constraints on the couplings of super-WIMPs with masses above 120
keV/c have been set. As an example, at a mass of 150 keV/c the most
stringent direct limits on the dimensionless couplings of axion-like particles
and dark photons to electrons of and
at 90% credible interval,
respectively, were obtained.Comment: 6 pages, 3 figures, submitted to Physical Review Letters, added list
of authors, updated ref. [21
Background free search for neutrinoless double beta decay with GERDA Phase II
The Standard Model of particle physics cannot explain the dominance of matter
over anti-matter in our Universe. In many model extensions this is a very
natural consequence of neutrinos being their own anti-particles (Majorana
particles) which implies that a lepton number violating radioactive decay named
neutrinoless double beta () decay should exist. The detection
of this extremely rare hypothetical process requires utmost suppression of any
kind of backgrounds.
The GERDA collaboration searches for decay of Ge
(^{76}\rm{Ge} \rightarrow\,^{76}\rm{Se} + 2e^-) by operating bare detectors
made from germanium with enriched Ge fraction in liquid argon. Here, we
report on first data of GERDA Phase II. A background level of
cts/(keVkgyr) has been achieved which is the world-best if
weighted by the narrow energy-signal region of germanium detectors. Combining
Phase I and II data we find no signal and deduce a new lower limit for the
half-life of yr at 90 % C.L. Our sensitivity of
yr is competitive with the one of experiments with
significantly larger isotope mass.
GERDA is the first experiment that will be background-free
up to its design exposure. This progress relies on a novel active veto system,
the superior germanium detector energy resolution and the improved background
recognition of our new detectors. The unique discovery potential of an
essentially background-free search for decay motivates a
larger germanium experiment with higher sensitivity.Comment: 14 pages, 9 figures, 1 table; ; data, figures and images available at
http://www.mpi-hd.mpg/gerda/publi
Results from the first use of low radioactivity argon in a dark matter search
Liquid argon is a bright scintillator with potent particle identification
properties, making it an attractive target for direct-detection dark matter
searches. The DarkSide-50 dark matter search here reports the first WIMP search
results obtained using a target of low-radioactivity argon. DarkSide-50 is a
dark matter detector, using two-phase liquid argon time projection chamber,
located at the Laboratori Nazionali del Gran Sasso. The underground argon is
shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3
relative to atmospheric argon. We report a background-free null result from
(2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with
our previous search using an atmospheric argon, the 90 % C.L. upper limit on
the WIMP-nucleon spin-independent cross section based on zero events found in
the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43
cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).Comment: Accepted by Phys. Rev.
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
The observation of neutrinoless double-beta decay (0)
would show that lepton number is violated, reveal that neutrinos are Majorana
particles, and provide information on neutrino mass. A discovery-capable
experiment covering the inverted ordering region, with effective Majorana
neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with
excellent energy resolution and extremely low backgrounds, at the level of
0.1 count /(FWHMtyr) in the region of the signal. The
current generation Ge experiments GERDA and the MAJORANA DEMONSTRATOR
utilizing high purity Germanium detectors with an intrinsic energy resolution
of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in
the 0 signal region of all 0
experiments. Building on this success, the LEGEND collaboration has been formed
to pursue a tonne-scale Ge experiment. The collaboration aims to develop
a phased 0 experimental program with discovery potential
at a half-life approaching or at years, using existing resources as
appropriate to expedite physics results.Comment: Proceedings of the MEDEX'17 meeting (Prague, May 29 - June 2, 2017
Characterization of 30 Ge enriched Broad Energy Ge detectors for GERDA Phase II
The GERmanium Detector Array (GERDA) is a low background experiment located
at the Laboratori Nazionali del Gran Sasso in Italy, which searches for
neutrinoless double beta decay of Ge into Se+2e. GERDA has
been conceived in two phases. Phase II, which started in December 2015,
features several novelties including 30 new Ge detectors. These were
manufactured according to the Broad Energy Germanium (BEGe) detector design
that has a better background discrimination capability and energy resolution
compared to formerly widely-used types. Prior to their installation, the new
BEGe detectors were mounted in vacuum cryostats and characterized in detail in
the HADES underground laboratory in Belgium. This paper describes the
properties and the overall performance of these detectors during operation in
vacuum. The characterization campaign provided not only direct input for GERDA
Phase II data collection and analyses, but also allowed to study detector
phenomena, detector correlations as well as to test the strength of pulse shape
simulation codes.Comment: 29 pages, 18 figure
Limits on uranium and thorium bulk content in GERDA Phase I detectors
Internal contaminations of U, U and Th in the bulk of
high purity germanium detectors are potential backgrounds for experiments
searching for neutrinoless double beta decay of Ge. The data from GERDA
Phase~I have been analyzed for alpha events from the decay chain of these
contaminations by looking for full decay chains and for time correlations
between successive decays in the same detector. No candidate events for a full
chain have been found. Upper limits on the activities in the range of a few
nBq/kg for Ra, Ac and Th, the long-lived daughter
nuclides of U, U and Th, respectively, have been
derived. With these upper limits a background index in the energy region of
interest from Ra and Th contamination is estimated which
satisfies the prerequisites of a future ton scale germanium double beta decay
experiment.Comment: 2 figures, 7 page
The background in the neutrinoless double beta decay experiment GERDA
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground
laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of
76Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the
Q-value of the decay, Q_bb. To avoid bias in the signal search, the present
analysis does not consider all those events, that fall in a 40 keV wide region
centered around Q_bb. The main parameters needed for the neutrinoless double
beta decay analysis are described. A background model was developed to describe
the observed energy spectrum. The model contains several contributions, that
are expected on the basis of material screening or that are established by the
observation of characteristic structures in the energy spectrum. The model
predicts a flat energy spectrum for the blinding window around Q_bb with a
background index ranging from 17.6 to 23.8*10^{-3} counts/(keV kg yr). A part
of the data not considered before has been used to test if the predictions of
the background model are consistent. The observed number of events in this
energy region is consistent with the background model. The background at Q-bb
is dominated by close sources, mainly due to 42K, 214Bi, 228Th, 60Co and alpha
emitting isotopes from the 226Ra decay chain. The individual fractions depend
on the assumed locations of the contaminants. It is shown, that after removal
of the known gamma peaks, the energy spectrum can be fitted in an energy range
of 200 kev around Q_bb with a constant background. This gives a background
index consistent with the full model and uncertainties of the same size
- …