31 research outputs found
Recommended from our members
Mammographic breast density: comparison of methods for quantitative evaluation.
PURPOSE: To evaluate the results from two software tools for measurement of mammographic breast density and compare them with observer-based scores in a large cohort of women. MATERIALS AND METHODS: Following written informed consent, a data set of 36 281 mammograms from 8867 women were collected from six United Kingdom centers in an ethically approved trial. Breast density was assessed by one of 26 readers on a visual analog scale and with two automated density tools. Mean differences were calculated as the mean of all the individual percentage differences between each measurement for each case (woman). Agreement in total breast volume, fibroglandular volume, and percentage density was assessed with the Bland-Altman method. Association with observer's scores was calculated by using the Pearson correlation coefficient (r). RESULTS: Correlation between the Quantra and Volpara outputs for total breast volume was r = 0.97 (P < .001), with a mean difference of 43.5 cm(3) for all cases representing 5.0% of the mean total breast volume. Correlation of the two measures was lower for fibroglandular volume (r = 0.86, P < .001). The mean difference was 30.3 cm(3) for all cases representing 21.2% of the mean fibroglandular tissue volume result. Quantra gave the larger value and the difference tended to increase with volume. For the two measures of percentage volume density, the mean difference was 1.61 percentage points (r = 0.78, P < .001). Comparison of observer's scores with the area-based density given by Quantra yielded a low correlation (r = 0.55, P < .001). Correlations of observer's scores with the volumetric density results gave r values of 0.60 (P < .001) and 0.63 (P < .001) for Quantra and Volpara, respectively. CONCLUSION: Automated techniques for measuring breast density show good correlation, but these are poorly correlated with observer's scores. However automated techniques do give different results that should be considered when informing patient personalized imaging. (©) RSNA, 2015 Clinical trial registration no. ISRCTN 73467396.Supported by the National Institute for Health Research’s Health Technology Assessment Programme.This is the final version of the article. It first appeared at http://pubs.rsna.org/doi/full/10.1148/radiol.1414150
Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial)
Purpose
To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features.
Materials and Methods
In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29–85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts.
Results
Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50–59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases).
Conclusion
The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts.
© RSNA, 2015The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256
Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial).
PURPOSE: To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. MATERIALS AND METHODS: In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29-85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. RESULTS: Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50-59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). CONCLUSION: The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. (©) RSNA, 2015.The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256
Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.
BACKGROUND: Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. AIM: To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. METHODS: The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). RESULTS: All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. CONCLUSIONS: Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging
Omega-3 polyunsaturated fatty acids favourably modulate cardiometabolic biomarkers in type 2 diabetes: a meta-analysis and meta-regression of randomized controlled trials
BACKGROUND: Randomized controlled trials (RCTs) suggest that supplementation with omega-3 polyunsaturated fatty acids (n-3PUFAs) may favourably modify cardiometabolic biomarkers in type 2 diabetes (T2DM). Previous meta-analyses are limited by insufficient sample sizes and omission of meta-regression techniques, and a large number of RCTs have subsequently been published since the last comprehensive meta-analysis. Updated information regarding the impact of dosage, duration or an interaction between these two factors is therefore warranted. The objective was to comprehensively assess the effect of n-3PUFAs supplementation on cardiometabolic biomarkers including lipid profiles, inflammatory parameters, blood pressure, and indices of glycaemic control, in people with T2DM, and identify whether treatment dosage, duration or an interaction thereof modify these effects. METHODS: Databases including PubMed and MEDLINE were searched until 13th July 2017 for RCTs investigating the effect of n-3PUFAs supplementation on lipid profiles, inflammatory parameters, blood pressure, and indices of glycaemic control. Data were pooled using random-effects meta-analysis and presented as standardised mean difference (Hedges g) with 95% confidence intervals (95% CI). Meta-regression analysis was performed to investigate the effects of duration of supplementation and total dosage of n-3PUFAs as moderator variables where appropriate. RESULTS: A total of 45 RCTs were identified, involving 2674 people with T2DM. n-3PUFAs supplementation was associated with significant reductions in LDL [ES: - 0.10, (95% CI - 0.17, - 0.03); p = 0.007], VLDL (ES: - 0.26 (- 0.51, - 0.01); p = 0.044], triglycerides (ES: - 0.39 (- 0.55, - 0.24; p ≤ 0.001] and HbA1c (ES: - 0.27 (- 0.48, - 0.06); p = 0.010]. Moreover, n-3PUFAs supplementation was associated with reduction in plasma levels of TNF-α [ES: - 0.59 (- 1.17, - 0.01); p = 0.045] and IL-6 (ES: - 1.67 (- 3.14, - 0.20); p = 0.026]. All other lipid markers, indices of glycaemic control, inflammatory parameters, and blood pressure remained unchanged (p > 0.05). CONCLUSIONS: n-3PUFAs supplementation produces favourable hypolipidemic effects, a reduction in pro-inflammatory cytokine levels and improvement in glycaemia. Neither duration nor dosage appear to explain the observed heterogeneity in response to n-3PUFAs. Trial registration This trial was registered at http://www.crd.york.ac.uk as CRD42016050802
What does 'complex' mean in palliative care? Triangulating qualitative findings from 3 settings
Background: Complex need for patients with a terminal illness distinguishes those who would benefit from
specialist palliative care from those who could be cared for by non-specialists. However, the nature of this complexity is
not well defined or understood. This study describes how health professionals, from three distinct settings in the United
Kingdom, understand complex need in palliative care.
Methods: Semi-structured qualitative interviews were conducted with professionals in primary care, hospital and hospice
settings. Thirty-four professionals including doctors, nurses and allied health professionals were recruited in total. Data
collected in each setting were thematically analysed and a workshop was convened to compare and contrast findings
across settings.
Results: The interaction between diverse multi-dimensional aspects of need, existing co-morbidities, intractable symptoms
and complicated social and psychological issues increased perceived complexity. Poor communication between patients
and their clinicians contributed to complexity. Professionals in primary and acute care described themselves as ‘generalists’
and felt they lacked confidence and skill in identifying and caring for complex patients and time for professional
development in palliative care.
Conclusions: Complexity in the context of palliative care can be inherent to the patient or perceived by health
professionals. Lack of confidence, time constraints and bed pressures contribute to perceived complexity, but
are amenable to change by training in identifying, prognosticating for, and communicating with patients
approaching the end of life
Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy
Background: Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods: ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligible if they had severe unilateral or bilateral carotid artery stenosis and both doctor and patient agreed that a carotid procedure should be undertaken, but they were substantially uncertain which one to choose. Patients were randomly allocated to CAS or CEA and followed up at 1 month and then annually, for a mean 5 years. Procedural events were those within 30 days of the intervention. Intention-to-treat analyses are provided. Analyses including procedural hazards use tabular methods. Analyses and meta-analyses of non-procedural strokes use Kaplan-Meier and log-rank methods. The trial is registered with the ISRCTN registry, ISRCTN21144362. Findings: Between Jan 15, 2008, and Dec 31, 2020, 3625 patients in 130 centres were randomly allocated, 1811 to CAS and 1814 to CEA, with good compliance, good medical therapy and a mean 5 years of follow-up. Overall, 1% had disabling stroke or death procedurally (15 allocated to CAS and 18 to CEA) and 2% had non-disabling procedural stroke (48 allocated to CAS and 29 to CEA). Kaplan-Meier estimates of 5-year non-procedural stroke were 2·5% in each group for fatal or disabling stroke, and 5·3% with CAS versus 4·5% with CEA for any stroke (rate ratio [RR] 1·16, 95% CI 0·86–1·57; p=0·33). Combining RRs for any non-procedural stroke in all CAS versus CEA trials, the RR was similar in symptomatic and asymptomatic patients (overall RR 1·11, 95% CI 0·91–1·32; p=0·21). Interpretation: Serious complications are similarly uncommon after competent CAS and CEA, and the long-term effects of these two carotid artery procedures on fatal or disabling stroke are comparable. Funding: UK Medical Research Council and Health Technology Assessment Programme
Evaluation of appendicitis risk prediction models in adults with suspected appendicitis
Background
Appendicitis is the most common general surgical emergency worldwide, but its diagnosis remains challenging. The aim of this study was to determine whether existing risk prediction models can reliably identify patients presenting to hospital in the UK with acute right iliac fossa (RIF) pain who are at low risk of appendicitis.
Methods
A systematic search was completed to identify all existing appendicitis risk prediction models. Models were validated using UK data from an international prospective cohort study that captured consecutive patients aged 16–45 years presenting to hospital with acute RIF in March to June 2017. The main outcome was best achievable model specificity (proportion of patients who did not have appendicitis correctly classified as low risk) whilst maintaining a failure rate below 5 per cent (proportion of patients identified as low risk who actually had appendicitis).
Results
Some 5345 patients across 154 UK hospitals were identified, of which two‐thirds (3613 of 5345, 67·6 per cent) were women. Women were more than twice as likely to undergo surgery with removal of a histologically normal appendix (272 of 964, 28·2 per cent) than men (120 of 993, 12·1 per cent) (relative risk 2·33, 95 per cent c.i. 1·92 to 2·84; P < 0·001). Of 15 validated risk prediction models, the Adult Appendicitis Score performed best (cut‐off score 8 or less, specificity 63·1 per cent, failure rate 3·7 per cent). The Appendicitis Inflammatory Response Score performed best for men (cut‐off score 2 or less, specificity 24·7 per cent, failure rate 2·4 per cent).
Conclusion
Women in the UK had a disproportionate risk of admission without surgical intervention and had high rates of normal appendicectomy. Risk prediction models to support shared decision‐making by identifying adults in the UK at low risk of appendicitis were identified
In the nude: factors determining the employment status of sex workers
This article analyses critically the 2018 Christchurch Employment Relations
Authority’s (the Authority) decision in Hamilton-Redmond and Clifford v
Casino Bar Limited, which found that two strip dancers were independent
contractors as opposed to employees. The article argues that this decision weakens
sex workers’ employment rights. It contends, therefore, that the Authority’s
decision diverges from the protective aims of the Prostitution Reform Act 2003. In
addition, in relation to employment law more broadly, the article argues that the
Authority’s decision reinforces the growing vulnerability experienced by workers
in precarious employment
Validating “Image box”-a new approach to multicentre radiology reviews using a web-based image review system: study protocol
ObjectivesTo validate the use of “Imagebox”- a web-based image review system for large scale multicentre trials.Patients and MethodsAs part of the multicentre trial ‘Prospective study of Outcomes in Sporadic versus Hereditary breast cancer (POSH) study’ mammograms were collected and digitised. Software was created allowing digitised mammograms to be viewed from any location with internet access. Two validation studies were performed. Firstly phantom studies using line-pairs (1–20 lpmm-1) to assess spatial resolution and the CDMAM 3.4 phantom were used to assess the visibility of gold discs for contrast detail .Secondly a comparison was made between the scoring of 77 patients’ original diagnostic analogue mammograms from 29 hospitals and the corresponding web images. Films and web images were scored by one experienced breast radiologist according to the BIRADS classification. At least 8 weeks elapsed between scoring images from the same patient.ResultsThe original analogue spatial resolution was 20 lpmm-1 and web resolution of the same image reduced at 8.9 lpmm-1. Contrast detail assessment demonstrated analogue and web images with near concordance and the image quality factor, IQFinv for the web was reduced but within the 95% confidence interval of the original mammograms. BIRADS final assessment showed good agreement between the analogue and the identical web images (Kappa 0.82).ConclusionThe overall reduction in spatial resolution did not adversely affect the quality of the diagnostic image on “Imagebox”. This may be due to its functionality, specifically the high magnification zoom which enhances diagnostic interpretation. Imagebox is a promising solution to address the logistical challenges for large breast imaging reviews and has further potential for education and self assessment