48 research outputs found

    Erratum to: 36th International Symposium on Intensive Care and Emergency Medicine

    Get PDF
    [This corrects the article DOI: 10.1186/s13054-016-1208-6.]

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Autoantibodies against type I IFNs in patients with life-threatening COVID-19

    Get PDF
    Interindividual clinical variability in the course of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is vast. We report that at least 101 of 987 patients with life-threatening coronavirus disease 2019 (COVID-19) pneumonia had neutralizing immunoglobulin G (IgG) autoantibodies (auto-Abs) against interferon-w (IFN-w) (13 patients), against the 13 types of IFN-a (36), or against both (52) at the onset of critical disease; a few also had auto-Abs against the other three type I IFNs. The auto-Abs neutralize the ability of the corresponding type I IFNs to block SARS-CoV-2 infection in vitro. These auto-Abs were not found in 663 individuals with asymptomatic or mild SARS-CoV-2 infection and were present in only 4 of 1227 healthy individuals. Patients with auto-Abs were aged 25 to 87 years and 95 of the 101 were men. A B cell autoimmune phenocopy of inborn errors of type I IFN immunity accounts for life-threatening COVID-19 pneumonia in at least 2.6% of women and 12.5% of men

    COVID-19 symptoms at hospital admission vary with age and sex: results from the ISARIC prospective multinational observational study

    Get PDF
    Background: The ISARIC prospective multinational observational study is the largest cohort of hospitalized patients with COVID-19. We present relationships of age, sex, and nationality to presenting symptoms. Methods: International, prospective observational study of 60 109 hospitalized symptomatic patients with laboratory-confirmed COVID-19 recruited from 43 countries between 30 January and 3 August 2020. Logistic regression was performed to evaluate relationships of age and sex to published COVID-19 case definitions and the most commonly reported symptoms. Results: ‘Typical’ symptoms of fever (69%), cough (68%) and shortness of breath (66%) were the most commonly reported. 92% of patients experienced at least one of these. Prevalence of typical symptoms was greatest in 30- to 60-year-olds (respectively 80, 79, 69%; at least one 95%). They were reported less frequently in children (≀ 18 years: 69, 48, 23; 85%), older adults (≄ 70 years: 61, 62, 65; 90%), and women (66, 66, 64; 90%; vs. men 71, 70, 67; 93%, each P < 0.001). The most common atypical presentations under 60 years of age were nausea and vomiting and abdominal pain, and over 60 years was confusion. Regression models showed significant differences in symptoms with sex, age and country. Interpretation: This international collaboration has allowed us to report reliable symptom data from the largest cohort of patients admitted to hospital with COVID-19. Adults over 60 and children admitted to hospital with COVID-19 are less likely to present with typical symptoms. Nausea and vomiting are common atypical presentations under 30 years. Confusion is a frequent atypical presentation of COVID-19 in adults over 60 years. Women are less likely to experience typical symptoms than men

    Spin singlet and quasiparticle excitations in cuprate superconductors

    No full text
    International audienceAbstract Non-collinear spin textures in ferromagnetic ultrathin films are attracting a renewed interest fueled by possible fine engineering of several magnetic interactions, notably the interfacial Dzyaloshinskii-Moriya interaction. This allows for the stabilization of complex chiral spin textures such as chiral magnetic domain walls (DWs), spin spirals, and magnetic skyrmions among others. We report here on the behavior of chiral DWs at ultrashort timescale after optical pumping in perpendicularly magnetized asymmetric multilayers. The magnetization dynamics is probed using time-resolved circular dichroism in x-ray resonant magnetic scattering (CD-XRMS). We observe a picosecond transient reduction of the CD-XRMS, which is attributed to the spin current-induced coherent and incoherent torques within the continuously varying spin texture of the DWs. We argue that a specific demagnetization of the inner structure of the DW induces a flow of spins from the interior of the neighboring magnetic domains. We identify this time-varying change of the DW texture shortly after the laser pulse as a distortion of the homochiral NĂ©el shape toward a transient mixed Bloch-NĂ©el-Bloch texture along a direction transverse to the DW

    Low-pressure support vs automatic tube compensation during spontaneous breathing trial for weaning

    No full text
    BACKGROUND: During spontaneous breathing trial, low-pressure support is thought to compensate for endotracheal tube resistance, but it actually should provide overassistance. Automatic tube compensation is an option available in the ventilator to compensate for flow-resistance of endotracheal tube. Its effects on patient effort have been poorly investigated. We aimed to compare the effects of low-pressure support and automatic tube compensation during spontaneous breathing trial on breathing power and lung ventilation distribution. RESULTS: We performed a randomized crossover study in 20 patients ready to wean. Each patient received both methods for 30 min separated by baseline ventilation: pressure support 0 cmH2O and automatic tube compensation 100% in one period and pressure support 7 cmH2O without automatic tube compensation in the other period, a 4 cmH2O positive end-expiratory pressure being applied in each. Same ventilator brand (Evita XL, Draeger, Germany) was used. Breathing power was assessed from Campbell diagram with esophageal pressure, airway pressure, flow and volume recorded by a data logger. Lung ventilation distribution was assessed by using electrical impedance tomography (Pulmovista, Draeger, Germany). During the last 2 min of low-pressure support and automatic compensation period breathing power and lung ventilation distribution were measured on each breath. Breathing power generated by the patient's respiratory muscles was 7.2 (4.4-9.6) and 9.7 (5.7-21.9) J/min in low-pressure support and automatic tube compensation periods, respectively (P = 0.011). Lung ventilation distribution was not different between the two methods. CONCLUSIONS: We found that ATC was associated with higher breathing power than low PS during SBT without altering the distribution of lung ventilation

    Lung and chest wall mechanics in patients with acute respiratory distress syndrome, expiratory flow limitation, and airway closure

    No full text
    Tidal expiratory flow limitation (EFL), which may herald airway closure (AC), is a mechanism of loss of aeration in ARDS. In this prospective, short-term, two-center study, we measured static and dynamic chest wall (Est,cw and Edyn,cw) and lung (Est,L and Edyn,L) elastance with esophageal pressure, EFL, and AC at 5 cmH(2)O positive end-expiratory pressure (PEEP) in intubated, sedated, and paralyzed ARDS patients. For EFL determination, we used the atmospheric method and a new device allowing comparison of tidal flow during expiration to PEEP and to atmosphere. AC was validated when airway opening pressure (AOP) assessed from volume-pressure curve was found greater than PEEP by at least 1 cmH(2)O. EFL was defined whenever flow did not increase between exhalation to PEEP and to atmosphere over all or part of expiration. Elastance values were expressed as percentage of normal predicted values (%N). Among the 25 patients included, eight had EFL (32%) and 13 AOP (52%). Between patients with and without EFL Edyn,cw [median (1st to 3rd quartiles)] was 70 (16-127) and 102 (70-142) %N (P = 0.32) and Edyn,L338 (332-763) and 224 (160-275) %N (P \textless 0.001). The corresponding values for Est,cw and Est,L were 70 (56-88) and 85 (64-103) %N (P = 0.35) and 248 (206-348) and 170 (144-195) (P = 0.02), respectively. Dynamic E(L) had an area receiver operating characteristic curve of 0.88 [95% confidence intervals 0.83-0.92] for EFL and 0.74[0.68-0.79] for AOP. Higher Edyn,L was accurate to predict EFL in ARDS patients; AC can occur independently of EFL, and both should be assessed concurrently in ARDS patients.NEW & NOTEWORTHY Expiratory flow limitation (EFL) and airway closure (AC) were observed in 32% and 52%, respectively, of 25 patients with ARDS investigated during mechanical ventilation in supine position with a positive end-expiratory pressure of 5 cmH(2)O. The performance of dynamic lung elastance to detect expiratory flow limitation was good and better than that to detect airway closure. The vast majority of patients with EFL also had AC; however, AC can occur in the absence of EFL

    Protracted viral shedding and viral load are associated with ICU mortality in Covid-19 patients with acute respiratory failure

    No full text
    International audienceAbstract Background Protracted viral shedding is common in hospitalized patients with COVID-19 pneumonia, and up to 40% display signs of pulmonary fibrosis on computed tomography (CT) after hospital discharge. We hypothesized that COVID-19 patients with acute respiratory failure (ARF) who die in intensive care units (ICU) have a lower viral clearance in the respiratory tract than ICU patients discharged alive, and that protracted viral shedding in respiratory samples is associated with patterns of fibroproliferation on lung CT. We, therefore, conducted a retrospective observational study, in 2 ICU of Lyon university hospital. Results 129 patients were included in the study, of whom 44 (34%) died in ICU. 432 RT-PCR for SARS-CoV-2 were performed and 137 CT scans were analyzed. Viral load was significantly higher in patients deceased as compared to patients alive at ICU discharge ( p < 0.001), after adjustment for the site of viral sampling and RT-PCR technique. The median time to SARS-CoV-2 negativation on RT-PCR was 19 days [CI 95 % :15–21] in patients alive at ICU discharge and 26 days [CI 95 % :17-infinity] in non-survivors at ICU discharge. Competitive risk regression identified patients who died in ICU and age as independent risk factors for longer time to SARS-CoV-2 negativation on RT-PCR, while antiviral treatment was independently associated with shorter time. None of the CT scores exploring fibroproliferation (i.e., bronchiectasis and reticulation scores) were significantly associated with time to SARS-CoV-2 negativation. Conclusions Viral load in respiratory samples is significantly lower and viral shedding significantly shorter in ICU survivors of COVID-19 associated acute respiratory failure. Protracted viral shedding is unrelated to occurrence of fibrosis on lung CT
    corecore