2,469 research outputs found
The clinical effects of insertion torque for implants placed in healed ridges : A two-year randomized controlled clinical trial
NMR of liquid 3He in clay pores at 1.5 K
In the present work a new method for studying porous media by nuclear
magnetic resonance of liquid 3He has been proposed. This method has been
demonstrated in an example of a clay mineral sample. For the first time the
integral porosity of clay sample has been measured. For investigated samples
the value of integral porosity is in the range of 10-30%. Inverse Laplace
transform of 3He longitudinal magnetization recovery curve has been carried
out, thus distribution of relaxation times T1 has been obtained.Comment: 9 pages, 5 figure
The Data Quality Monitoring for the CMS Silicon Strip Tracker
The CMS Silicon Strip Tracker (SST), consisting of more than 10 million channels, is organized in about 15,000 detector modules and it is the largest silicon strip tracker ever built for high energy physics experiments. The Data Quality Monitoring system for the Tracker has been developed within the CMS Software framework. More than 100,000 monitorable quantities need to be managed by the DQM system that organizes them in a hierarchical structure reflecting the detector arrangement in subcomponents and the various levels of data processing. Monitorable quantities computed at the level of individual detectors are processed to extract automatic quality checks and summary results that can be visualized with specialized graphical user interfaces. In view of the great complexity of the CMS Tracker detector the standard visualization tools based on histograms have been complemented with 2 and 3 dimensional graphical images of the subdetector that can show the whole detector down to single channel resolution. The functionalities of the CMS Silicon Strip Tracker DQM system and the experience acquired during the SST commissioning will be described
Gravitational sliding of the Mt. Etna massif along a sloping basement
Geological field evidence and laboratory modelling indicate that volcanoes constructed on slopes slide downhill. If this happens on an active volcano, then the movement will distort deformation data and thus potentially compromise interpretation. Our recent GPS measurements demonstrate that the entire edifice of Mt. Etna is sliding to the ESE, the overall direction of slope of its complex, rough sedimentary basement. We report methods of discriminating the sliding vector from other deformation processes and of measuring its velocity, which averaged 14 mm yearâ1 during four intervals between 2001 and 2012. Though sliding of one sector of a volcano due to flank instability is widespread and well-known, this is the first time basement sliding of an entire active volcano has been directly observed. This is important because the geological record shows that such sliding volcanoes are prone to devastating sector collapse on the downslope side, and whole volcano migration should be taken into account when assessing future collapse hazard. It is also important in eruption forecasting, as the sliding vector needs to be allowed for when interpreting deformation events that take place above the sliding basement within the superstructure of the active volcano, as might occur with dyke intrusion or inflation/deflation episodes
Performance of the LHCb vertex locator
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 ÎŒm is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 ÎŒm for translations in the plane transverse to the beam. A primary vertex resolution of 13 ÎŒm in the transverse plane and 71 ÎŒm along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 ÎŒm is achieved for particles with transverse momentum greater than 1 GeV/c
Precision luminosity measurements at LHCb
Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy âs. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for âs = 2.76, 7 and 8 TeV (proton-proton collisions) and for âsNN = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at âs = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider
Measurement of the CKM angle Îł from a combination of B±âDh± analyses
A combination of three LHCb measurements of the CKM angle Îł is presented. The decays B±âD K± and
B±âDϱ are used, where D denotes an admixture of D0 and D0 mesons, decaying into K+Kâ, Ï+Ïâ, K±Ïâ, K±ÏâϱÏâ, K0SÏ+Ïâ, or K0S K+Kâ ïŹnal states. All measurements use a dataset corresponding to 1.0 fbâ1 of integrated luminosity. Combining results from B±âD K± decays alone a best-ïŹt value of
Îł =72.0⊠is found, and conïŹdence intervals are set
Îł â [56.4,86.7]⊠at 68% CL,
Îł â [42.6,99.6]⊠at 95% CL.
The best-ïŹt value of Îł found from a combination of results from B±âDϱ decays alone, is Îł =18.9âŠ,
and the conïŹdence intervals
Îł â [7.4,99.2]⊠âȘ [167.9,176.4]⊠at 68% CL
are set, without constraint at 95% CL. The combination of results from B± â D K± and B± â Dϱ
decays gives a best-ïŹt value of Îł =72.6⊠and the conïŹdence intervals
Îł â [55.4,82.3]⊠at 68% CL,
Îł â [40.2,92.7]⊠at 95% CL
are set. All values are expressed modulo 180âŠ, and are obtained taking into account the effect of D0âD0
mixing
Measurement of the ratio of branching fractions BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma)
The ratio of branching fractions of the radiative B decays B0 -> K*0 gamma
and Bs0 -> phi gamma has been measured using 0.37 fb-1 of pp collisions at a
centre of mass energy of sqrt(s) = 7 TeV, collected by the LHCb experiment. The
value obtained is BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma) = 1.12 +/- 0.08
^{+0.06}_{-0.04} ^{+0.09}_{-0.08}, where the first uncertainty is statistical,
the second systematic and the third is associated to the ratio of fragmentation
fractions fs/fd. Using the world average for BR(B0 -> K*0 gamma) = (4.33 +/-
0.15) x 10^{-5}, the branching fraction BR(Bs0 -> phi gamma) is measured to be
(3.9 +/- 0.5) x 10^{-5}, which is the most precise measurement to date.Comment: 15 pages, 1 figure, 2 table
- âŠ