331 research outputs found

    Standardisation of magnetic nanoparticles in liquid suspension

    Get PDF
    Suspensions of magnetic nanoparticles offer diverse opportunities for technology innovation, spanning a large number of industry sectors from imaging and actuation based applications in biomedicine and biotechnology, through large-scale environmental remediation uses such as water purification, to engineering-based applications such as position-controlled lubricants and soaps. Continuous advances in their manufacture have produced an ever-growing range of products, each with their own unique properties. At the same time, the characterisation of magnetic nanoparticles is often complex, and expert knowledge is needed to correctly interpret the measurement data. In many cases, the stringent requirements of the end-user technologies dictate that magnetic nanoparticle products should be clearly defined, well characterised, consistent and safe; or to put it another way—standardised. The aims of this document are to outline the concepts and terminology necessary for discussion of magnetic nanoparticles, to examine the current state-of-the-art in characterisation methods necessary for the most prominent applications of magnetic nanoparticle suspensions, to suggest a possible structure for the future development of standardisation within the field, and to identify areas and topics which deserve to be the focus of future work items. We discuss potential roadmaps for the future standardisation of this developing industry, and the likely challenges to be encountered along the way

    The effect of gas phase flame retardants on fire effluent toxicity

    Get PDF
    Standard industry formulations of flame retarded aliphatic polyamides, meeting UL 94 V-0, have been burned under controlled conditions, and the yields of the major asphyxiants, carbon monoxide (CO) and hydrogen cyanide (HCN) have been quantified. Although both the combination of aluminium phosphinate and melamine polyphosphate, and the combination of brominated polystyrene and antimony oxide, inhibit combustion reactions in the gas phase, this study shows that the phosphorus causes a much smaller increase in the CO and HCN yields than antimony-bromine. The mechanisms of CO and HCN generation and destruction are related to the flame inhibition reactions. Both CO and HCN form early in the flame, and the OH radical is critical for their destruction. Crucial, in the context of the flame inhibition mechanism, is the observation that the phosphorus system reduces the H and O radical concentrations without a corresponding decrease in the OH radical concentration; conversely, the bromine system reduces all three of the key radical concentrations, H, O and OH, and thus increases the fire toxicity, by inhibiting decomposition of CO and HCN. Moreover, while the phosphorus flame retardant is effective as an ignition suppressant at lower temperatures (corresponding to early flaming), this is effect “switches off” at high temperatures, minimising the potential increase in fire toxicity, once the fire develops. Since flame retardants are most effective as ignition suppressants, and at the early stages of flaming combustion, while most fire deaths and injuries result from toxic gas inhalation from more developed fires, it is clearly advantageous to have an effective gas phase flame retardant which only causes a small increase in the toxic product yield

    Application of standardization for the design and construction of carbon nanotube-based product pilot lines in compliance with EU regulation on machinery

    Get PDF
    The "PLATFORM" manufacturing ecosystem for pilot production of pre-commercial CNT-based nano-enabled products, consists of three pilot lines (PPLs) for the manufacture of buckypapers, doped prepregs and doped veils. The PPLs have been constructed with the ultimate goal to commercialize these products in the European market in 2020/2022.This goal requires having the PPLs in compliance with the applicable product safety regulation by that date (CE marking). The main EU regulation for new machinery (as the PPLs) is the Directive 2006/42/EC on Machinery (MD). This Directive sets out the general mandatory Essential Health and Safety Requirements (EHSRs) related to the design and construction of machinery, while particular technical specifications for fulfilling them are provided in European harmonized standards. Application of harmonized standards is voluntary but confers a presumption of conformity with the EHSRs they cover. The PPLs are unique machines for own use and must comply with the MD before they are put into service, in 2020/2022. But the MD does not provide specific EHSRs for nanosafety and no harmonized standards are available in this field for the safe design of the PPLs. In this context, this paper shows the standardization strategy followed by the project PLATFORM (GA 646307) to design the PPLs in compliance with the EHSR referred to the risks to health resulting from hazardous substances emitted by machinery (MD, Annex I, EHSR 1.5.13). In the absence of nanosafety harmonized standards to satisfy the aforementioned EHSR, the design and design verification of the PPLs were carried out through A & B - type harmonized standards (e.g. EN ISO 12100, EN ISO 14123-1/2), and other European and international standards.The projects PLATFORM and OASIS have received funding from the European Union’s Horizon 2020 research and innovation programme, under grant agreements Nº 646307 and Nº 814581, respectively. This paper reflects only the authors’ views, and the Commission is not responsible for any use that may be made of the information contained therein

    Analysis of multivariate stochastic signals sampled by on-line particle analyzers: Application to the quantitative assessment of occupational exposure to NOAA in multisource industrial scenarios (MSIS)

    Get PDF
    In multisource industrial scenarios (MSIS) coexist NOAA generating activities with other productive sources of airborne particles, such as parallel processes of manufacturing or electrical and diesel machinery. A distinctive characteristic of MSIS is the spatially complex distribution of aerosol sources, as well as their potential differences in dynamics, due to the feasibility of multi-task configuration at a given time. Thus, the background signal is expected to challenge the aerosol analyzers at a probably wide range of concentrations and size distributions, depending of the multisource configuration at a given time. Monitoring and prediction by using statistical analysis of time series captured by on-line particle analyzersin industrial scenarios, have been proven to be feasible in predicting PNC evolution provided a given quality of net signals (difference between signal at source and background). However the analysis and modelling of non-consistent time series, influenced by low levels of SNR (Signal-Noise Ratio) could build a misleading basis for decision making. In this context, this work explores the use of stochastic models based on ARIMA methodology to monitor and predict exposure values (PNC). The study was carried out in a MSIS where an case study focused on the manufacture of perforated tablets of nano-TiO2 by cold pressing was performed.Research carried out by projects SCAFFOLD and EHS Advance were made possible thanks to funding from European Commission through FP7 (GA 319092) and Basque Country Government through ETORTEK Programme

    Residual stress measurement round robin on an electron beam welded joint between austenitic stainless steel 316L(N) and ferritic steel P91

    Get PDF
    This paper is a research output of DMW-Creep project which is part of a national UK programme through the RCUK Energy programme and India's Department of Atomic Energy. The research is focussed on understanding the characteristics of welded joints between austenitic stainless steel and ferritic steel that are widely used in many nuclear power generating plants and petrochemical industries as well as conventional coal and gas-fired power systems. The members of the DMW-Creep project have under- taken parallel round robin activities measuring the residual stresses generated by a dissimilar metal weld (DMW) between AISI 316L(N) austenitic stainless steel and P91 ferritic-martensitic steel. Electron beam (EB) welding was employed to produce a single bead weld on a plate specimen and an additional smoothing pass (known cosmetic pass) was then introduced using a defocused beam. The welding re- sidual stresses have been measured by five experimental methods including (I) neutron diffraction (ND), (II) X-Ray diffraction (XRD), (III) contour method (CM), (IV) incremental deep hole drilling (iDHD) and (V) incremental centre hole drilling (iCHD). The round robin measurements of weld residual stresses are compared in order to characterise surface and sub-surface residual stresses comprehensively

    Studying the Effect of Adding Titanium Dioxide (TiO2) Nanoparticles on the Compressive Strength of Chemical and Heat-activated Acrylic Denture Base Resins

    Get PDF
    Problem: The commonly used acrylic resins for fabricating denture base suffer from poor mechanical properties. Aim: This study aimed to assess the effect of incorporating Titanium Dioxide (TiO2) nanoparticles (NPs) as a reinforcement agent on the compressive strength of acrylic denture base materials. Materials and methods: Thirty-two cylindrical specimens (22 mm in height and 12 mm in diameter) were prepared from PMMA resins with and without TiO2 NPs. They were allocated into two main groups according to the materials used such as cold cure and heat cure denture base resins and then subdivided into two subgroups each containing eight specimens: control (without nanoparticles) and experimental (with 2 wt.% TiO2 NPs). TiO2 NPs were synthesized via a chemical processing route and particle morphology and size distribution were assessed using SEM and AFM while XRD technique was employed to determine the crystalline structure of the NPs. Compression test was performed on the specimens using a universal Instron testing machine to compare the compressive strength. Results: Size of crystalline TiO2 NPs varied between 40-80 nm. The mean compressive strength for the cold cure acrylic resin (control group) and its nanocomposite (experimental group) were found as 15.37 MPa and 17.42 MPa while for the heat cure acrylic resin and its nanocomposite were 23.04 MPa and 24.30 MPa. A statistically significant difference was recorded in the compressive strength between the cold cure acrylic resin and its nanocomposite. However, the difference was non-significant in the case of heat cure acrylic resin. Conclusion: The compressive strength of both cold cure and heat cure acrylic resins increased after incorporation TiO2 NPs

    Protein content prediction in single wheat kernels using hyperspectral imaging

    Get PDF
    Hyperspectral imaging (HSI) combines Near-infrared (NIR) spectroscopy and digital imaging to give information about the chemical properties of objects and their spatial distribution. Protein content is one of the most important quality factors in wheat. It is known to vary widely depending on the cultivar, agronomic and climatic conditions. However, little information is known about single kernel protein variation within batches. The aim of the present work was to measure the distribution of protein content in whole wheat kernels on a single kernel basis, and to apply HSI to predict this distribution. Wheat samples from 2013 and 2014 harvests were sourced from UK millers and wheat breeders, and individual kernels were analysed by HSI and by the Dumas combustion method for total protein content. HSI was applied in the spectral region 980-2500 nm in reflectance mode using the push-broom approach. Single kernel spectra were used to develop partial least squares (PLS) regression models for protein prediction of intact single grains. The protein content ranged from 6.2 to 19.8% (“as-is” basis), with significantly higher values for hard wheats. The performance of the calibration model was evaluated using the coefficient of determination (R2) and the root mean square error (RMSE) from 3250 samples used for calibration and 868 used for external validation. The calibration performance for single kernel protein content was R2 of 0.82 and 0.79, and RMSE of 0.86 and 0.94% for the calibration and validation dataset, enabling quantification of the protein distribution between kernels and even visualisation within the same kernel. The performance of the single kernel measurement was poorer than that typically obtained for bulk samples, but is acceptable for some specific applications. The use of separate calibrations built by separating hard and soft wheat, or on kernels placed on similar orientation did not greatly improve the prediction ability. We simulated the use of the lower cost InGaAs detector (1000-1700 nm), and reported that the use of proposed HgCdTe detectors over a restricted spectral range gave a lower prediction error (RMSEC=0.86% vs 1.06%, for HgCdTe and InGaAs, respectively), and 26 increased R2 value (Rc2=0.82 vs 0.73)
    • …
    corecore