214 research outputs found
Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range
A beam line for electrons with energies in the range of 1 to 45 GeV, low
contamination of hadrons and muons and high intensity up to 10^6 per
accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A
beam tagging system based on drift chambers with 160 micron resolution was able
to measure relative electron beam momentum precisely. The resolution sigma_p p
was 0.13% at 45 GeV where multiple scattering is negligible. This test beam
setup provided the possibility to study properties of lead tungstate crystals
(PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic
Calorimeter grou
Recommended from our members
The MANX muon cooling demonstration experiment
MANX is an experiment to prove that effective six-dimensional (6D) muon beam cooling can be achieved in a Helical Cooling Channel (HCC) using ionization-cooling with helical and solenoidal magnets in a novel configuration. The aim is to demonstrate that 6D muon beam cooling is understood well enough to plan intense neutrino factories and high-luminosity muon colliders. The experiment consists of the HCC magnet that envelops a liquid helium energy absorber, upstream and downstream instrumentation to measure the beam parameters before and after cooling, and emittance matching sections between the detectors and the HCC
Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams
We report on the effects of radiation on the light output of lead tungstate
crystals. The crystals were irradiated by pure, intense high energy electron
and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The
crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai
(China). These studies were carried out at the 70-GeV proton accelerator in
Protvino
Expected Accuracy in a Measurement of the CKM Angle Using a Dalitz Plot Analysis of \boldmath B^0 \to \rho \pi Decays in the BTeV Project
A precise measurement of the angle in the CKM triangle is very
important for a complete test of Standard Model. A theoretically clean method
to extract is provided by B decays. Monte Carlo
simulations to obtain the BTeV reconstruction efficiency and to estimate the
signal to background ratio for these decays were performed. Finally the
time-dependent Dalitz plot analysis, using the isospin amplitude formalism for
tree and penguin contributions, was carried out. It was shown that in one year
of data taking BTeV could achieve an accuracy on better than
5.Comment: 26 pages, 11 figures. To be submitted to Phys.Atom.Nuc
B Physics at the Tevatron: Run II and Beyond
This report provides a comprehensive overview of the prospects for B physics
at the Tevatron. The work was carried out during a series of workshops starting
in September 1999. There were four working groups: 1) CP Violation, 2) Rare and
Semileptonic Decays, 3) Mixing and Lifetimes, 4) Production, Fragmentation and
Spectroscopy. The report also includes introductory chapters on theoretical and
experimental tools emphasizing aspects of B physics specific to hadron
colliders, as well as overviews of the CDF, D0, and BTeV detectors, and a
Summary.Comment: 583 pages. Further information on the workshops, including
transparencies, can be found at the workshop's homepage:
http://www-theory.lbl.gov/Brun2/. The report is also available in 2-up
http://www-theory.lbl.gov/Brun2/report/report2.ps.gz or chapter-by-chapter
http://www-theory.lbl.gov/Brun2/report
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
- …