633 research outputs found

    Implanted Microsensor Continuous IOP Telemetry Suggests Gaze and Eyelid Closure Effects on IOP-A Preliminary Study

    Get PDF
    PurposeTo explore the effect of gaze direction and eyelid closure on intraocular pressure (IOP).MethodsEleven patients with primary open-angle glaucoma previously implanted with a telemetric IOP sensor were instructed to view eight equally-spaced fixation targets each at three eccentricities (10°, 20°, and 25°). Nine patients also performed eyelid closure. IOP was recorded via an external antenna placed around the study eye. Differences of mean IOP between consecutive gaze positions were calculated. Furthermore, the effect of eyelid closure on gaze-dependent IOP was assessed.ResultsThe maximum IOP increase was observed at 25° superior gaze (mean ± SD: 4.4 ± 4.9 mm Hg) and maximum decrease at 25° inferonasal gaze (-1.6 ± 0.8 mm Hg). There was a significant interaction between gaze direction and eccentricity (P = 0.003). Post-hoc tests confirmed significant decreases inferonasally for all eccentricities (mean ± SEM: 10°: -0.7 ± 0.2, P = 0.007; 20°: -1.1 ± 0.2, P = 0.006; and 25°: -1.6 ± 0.2, P = 0.006). Eight of 11 eyes showed significant IOP differences between superior and inferonasal gaze at 25°. IOP decreased during eyelid closure, which was significantly lower than downgaze at 25° (mean ± SEM: -2.1 ± 0.3 mm Hg vs. -0.7 ± 0.2 mm Hg, P = 0.014).ConclusionsOur data suggest that IOP varies reproducibly with gaze direction, albeit with patient variability. IOP generally increased in upgaze but decreased in inferonasal gaze and on eyelid closure. Future studies should investigate the patient variability and IOP dynamics

    Presenting signs and patient co-variables in Gaucher disease : outcome of the Gaucher Earlier Diagnosis Consensus (GED-C) Delphi initiative

    Get PDF
    © 2018 The Authors. Internal Medicine Journal by Wiley Publishing Asia Pty Ltd on behalf of Royal Australasian College of Physicians.Background: Gaucher disease (GD) presents with a range of signs and symptoms. Physicians can fail to recognise the early stages of GD owing to a lack of disease awareness, which can lead to significant diagnostic delays and sometimes irreversible but avoidable morbidities. Aim: The Gaucher Earlier Diagnosis Consensus (GED-C) initiative aimed to identify signs and co-variables considered most indicative of early type 1 and type 3 GD, to help non-specialists identify ‘at-risk’ patients who may benefit from diagnostic testing. Methods: An anonymous, three-round Delphi consensus process was deployed among a global panel of 22 specialists in GD (median experience 17.5 years, collectively managing almost 3000 patients). The rounds entailed data gathering, then importance ranking and establishment of consensus, using 5-point Likert scales and scoring thresholds defined a priori. Results: For type 1 disease, seven major signs (splenomegaly, thrombocytopenia, bone-related manifestations, anaemia, hyperferritinaemia, hepatomegaly and gammopathy) and two major co-variables (family history of GD and Ashkenazi-Jewish ancestry) were identified. For type 3 disease, nine major signs (splenomegaly, oculomotor disturbances, thrombocytopenia, epilepsy, anaemia, hepatomegaly, bone pain, motor disturbances and kyphosis) and one major co-variable (family history of GD) were identified. Lack of disease awareness, overlooking mild early signs and failure to consider GD as a diagnostic differential were considered major barriers to early diagnosis. Conclusion: The signs and co-variables identified in the GED-C initiative as potentially indicative of early GD will help to guide non-specialists and raise their index of suspicion in identifying patients potentially suitable for diagnostic testing for GD.Peer reviewedFinal Published versio

    Discovery of interstellar mercapto radicals (SH) with the GREAT instrument on SOFIA

    Full text link
    We report the first detection of interstellar mercapto radicals, obtained along the sight-line to the submillimeter continuum source W49N. We have used the GREAT instrument on SOFIA to observe the 1383 GHz Doublet Pi 3/2 J = 5/2 - 3/2 lambda doublet in the upper sideband of the L1 receiver. The resultant spectrum reveals SH absorption in material local to W49N, as well as in foreground gas, unassociated with W49N, that is located along the sight-line. For the foreground material at velocities in the range 37 - 44 km/s with respect to the local standard of rest, we infer a total SH column density ~ 2.6 E+12 cm-2, corresponding to an abundance of ~ 7 E-9 relative to H2, and yielding an SH/H2S abundance ratio ~ 0.13. The observed SH/H2S abundance ratio is much smaller than that predicted by standard models for the production of SH and H2S in turbulent dissipation regions and shocks, and suggests that the endothermic neutral-neutral reaction SH + H2 -> H2S + H must be enhanced along with the ion-neutral reactions believed to produce CH+ and SH+ in diffuse molecular clouds.Comment: Accepted for publication in Astronomy and Astrophysics (SOFIA/GREAT special issue

    Therapeutic targeting of integrin αvβ6 in breast cancer

    Get PDF
    BACKGROUND: Integrin ?v?6 promotes migration, invasion, and survival of cancer cells; however, the relevance and role of ?v?6 has yet to be elucidated in breast cancer.METHODS: Protein expression of integrin subunit beta6 (?6) was measured in breast cancers by immunohistochemistry (n &gt; 2000) and ITGB6 mRNA expression measured in the Molecular Taxonomy of Breast Cancer International Consortium dataset. Overall survival was assessed using Kaplan Meier curves, and bioinformatics statistical analyses were performed (Cox proportional hazards model, Wald test, and Chi-square test of association). Using antibody (264RAD) blockade and siRNA knockdown of ?6 in breast cell lines, the role of ?v?6 in Human Epidermal Growth Factor Receptor 2 (HER2) biology (expression, proliferation, invasion, growth in vivo) was assessed by flow cytometry, MTT, Transwell invasion, proximity ligation assay, and xenografts (n ? 3), respectively. A student's t-test was used for two variables; three-plus variables used one-way analysis of variance with Bonferroni's Multiple Comparison Test. Xenograft growth was analyzed using linear mixed model analysis, followed by Wald testing and survival, analyzed using the Log-Rank test. All statistical tests were two sided.RESULTS: High expression of either the mRNA or protein for the integrin subunit ?6 was associated with very poor survival (HR = 1.60, 95% CI = 1.19 to 2.15, P = .002) and increased metastases to distant sites. Co-expression of ?6 and HER2 was associated with worse prognosis (HR = 1.97, 95% CI = 1.16 to 3.35, P = .01). Monotherapy with 264RAD or trastuzumab slowed growth of MCF-7/HER2-18 and BT-474 xenografts similarly (P &lt; .001), but combining 264RAD with trastuzumab effectively stopped tumor growth, even in trastuzumab-resistant MCF-7/HER2-18 xenografts.CONCLUSIONS: Targeting ?v?6 with 264RAD alone or in combination with trastuzumab may provide a novel therapy for treating high-risk and trastuzumab-resistant breast cancer patients.<br/

    Optimising the Diagnosis of Prostate Cancer in the Era of Multiparametric Magnetic Resonance Imaging : A Cost-effectiveness Analysis Based on the Prostate MR Imaging Study (PROMIS)

    Get PDF
    Background The current recommendation of using transrectal ultrasound-guided biopsy (TRUSB) to diagnose prostate cancer misses clinically significant (CS) cancers. More sensitive biopsies (eg, template prostate mapping biopsy [TPMB]) are too resource intensive for routine use, and there is little evidence on multiparametric magnetic resonance imaging (MPMRI). Objective To identify the most effective and cost-effective way of using these tests to detect CS prostate cancer. Design, setting, and participants Cost-effectiveness modelling of health outcomes and costs of men referred to secondary care with a suspicion of prostate cancer prior to any biopsy in the UK National Health Service using information from the diagnostic Prostate MR Imaging Study (PROMIS). Intervention Combinations of MPMRI, TRUSB, and TPMB, using different definitions and diagnostic cut-offs for CS cancer. Outcome measurements and statistical analysis Strategies that detect the most CS cancers given testing costs, and incremental cost-effectiveness ratios (ICERs) in quality-adjusted life years (QALYs) given long-term costs. Results and limitations The use of MPMRI first and then up to two MRI-targeted TRUSBs detects more CS cancers per pound spent than a strategy using TRUSB first (sensitivity = 0.95 [95% confidence interval {CI} 0.92–0.98] vs 0.91 [95% CI 0.86–0.94]) and is cost effective (ICER = £7,076 [€8350/QALY gained]). The limitations stem from the evidence base in the accuracy of MRI-targeted biopsy and the long-term outcomes of men with CS prostate cancer. Conclusions An MPMRI-first strategy is effective and cost effective for the diagnosis of CS prostate cancer. These findings are sensitive to the test costs, sensitivity of MRI-targeted TRUSB, and long-term outcomes of men with cancer, which warrant more empirical research. This analysis can inform the development of clinical guidelines. Patient summary We found that, under certain assumptions, the use of multiparametric magnetic resonance imaging first and then up to two transrectal ultrasound-guided biopsy is better than the current clinical standard and is good value for money. The use of multiparametric magnetic resonance imaging before transrectal ultrasound-guided biopsy can detect more clinically significant prostate cancer and be cost effective compared with the use of imaging post-biopsy

    CMB Polarimetry using Correlation Receivers with the PIQUE and CAPMAP Experiments

    Full text link
    The Princeton IQU Experiment (PIQUE) and the Cosmic Anisotropy Polarization MAPper (CAPMAP) are experiments designed to measure the polarization of the Cosmic Microwave Background (CMB) on sub-degree scales in an area within 1 degree of the North Celestial Pole using heterodyne correlation polarimeters and off-axis telescopes located in central New Jersey. PIQUE produced the tightest limit on the CMB polarization prior to its detection by DASI, while CAPMAP has recently detected polarization at l~1000. The experimental methods and instrumentation for these two projects are described in detail with emphasis on the particular challenges involved in measuring the tiny polarized component of the CMB.Comment: 70 pages, 13 tables, 18 figures. Accepted by ApJS; tentative publication ApJS July 2005, v159
    • …
    corecore