431 research outputs found
Transcutaneous Electrical Nerve Stimulation (TENS) for chronic pain - an overview of Cochrane reviews (Protocol)
This is the protocol for a review and there is no abstract. The objectives are as follows: To provide an overview of evidence from Cochrane systematic reviews of the effectiveness of TENS to reduce pain in adults with chronic pain (excluding headache or migraine). To provide an overview of evidence from Cochrane systematic reviews of the safety of TENS to reduce pain in adults with chronic pain (excluding headache or migraine). To identify possible sources of inconsistency in the approaches taken to evaluating the evidence related to TENS for chronic pain (excluding headache or migraine) in the Cochrane Library with a view to recommending strategies to improve consistency. To highlight areas of remaining uncertainty regarding the effectiveness of TENS for chronic pain (excluding headache or migraine) with a view to recommending strategies to reduce any uncertainty
Interferometric characterization of the optical window for LISA Pathfinder and LISA
In LISA Pathfinder and LISA the position fluctuations of drag free test masses will be determined interferometrically to picometer precision. To this end, laser light is brought to interference on an ultra stable optical bench after being reflected on the test mass, which needs to be in an ultra-high vacuum. The present baseline for both missions includes a separate vacuum enclosure for each test mass, so that the sensing laser beam has to pass through an optical window. This window is therefore a transmissive element in the interferometer and its associated pathlength fluctuations are potentially significant. We have selected an athermal glass that should minimize the thermally induced pathlength changes.Several prototype windows, both mounted and unmounted, have been produced and characterized. The pathlength sensitivity to both temperature fluctuations and temperature gradients has been measured with a dedicated interferometer prototype. We have also compared the long-term stability of the LISA Technology Package interferometer when an optical window is present in the optical path to the situation without window. Finally, glass samples have been radiated and the absorption in the glass after the radiation tests has been measured to be negligible at the wavelength of interest (1064 nm). We present here the results of our measurements, which indicate that using a window does not influence the interferometer performance
Continuation-Passing C: compiling threads to events through continuations
In this paper, we introduce Continuation Passing C (CPC), a programming
language for concurrent systems in which native and cooperative threads are
unified and presented to the programmer as a single abstraction. The CPC
compiler uses a compilation technique, based on the CPS transform, that yields
efficient code and an extremely lightweight representation for contexts. We
provide a proof of the correctness of our compilation scheme. We show in
particular that lambda-lifting, a common compilation technique for functional
languages, is also correct in an imperative language like C, under some
conditions enforced by the CPC compiler. The current CPC compiler is mature
enough to write substantial programs such as Hekate, a highly concurrent
BitTorrent seeder. Our benchmark results show that CPC is as efficient, while
using significantly less space, as the most efficient thread libraries
available.Comment: Higher-Order and Symbolic Computation (2012). arXiv admin note:
substantial text overlap with arXiv:1202.324
Paracetamol, NSAIDS and opioid analgesics for chronic low back pain: A network meta-analysis (Protocol)
This is a protocol for a Cochrane Review (Intervention). The objectives are as follows:
To answer the clinical question: ‘what analgesic medicine shall I prescribe this patient with chronic low back pain to reduce their pain?’.
The objectives are to determine the analgesic effects, safety, effect on function, and relative rank according to analgesic effect, safety and effect on function of a single course of opioid analgesics, NSAIDs or paracetamol or combinations of these medicines
A Symmetric Approach to Compilation and Decompilation
Just as specializing a source interpreter can achieve compilation from a source language to a target language, we observe that specializing a target interpreter can achieve compilation from the target language to the source language. In both cases, the key issue is the choice of whether to perform an evaluation or to emit code that represents this evaluation. We substantiate this observation by specializing two source interpreters and two target interpreters. We first consider a source language of arithmetic expressions and a target language for a stack machine, and then the lambda-calculus and the SECD-machine language. In each case, we prove that the target-to-source compiler is a left inverse of the source-to-target compiler, i.e., it is a decompiler. In the context of partial evaluation, compilation by source-interpreter specialization is classically referred to as a Futamura projection. By symmetry, it seems logical to refer to decompilation by target-interpreter specialization as a Futamura embedding
Sub-femto-g free fall for space-based gravitational wave observatories: LISA pathfinder results
We report the first results of the LISA Pathfinder in-flight experiment. The results demonstrate that two free-falling reference test masses, such as those needed for a space-based gravitational wave observatory like LISA, can be put in free fall with a relative acceleration noise with a square root of the power spectral density of 5.2 ± 0.1 fm s−2/√Hz or (0.54 ± 0.01) × 10−15 g/√Hz, with g the standard gravity, for frequencies between 0.7 and 20 mHz. This value is lower than the LISA Pathfinder requirement by more than a factor 5 and within a factor 1.25 of the requirement for the LISA mission, and is compatible with Brownian noise from viscous damping due to the residual gas surrounding the test masses. Above 60 mHz the acceleration noise is dominated by interferometer displacement readout noise at a level of (34.8 ± 0.3) fm/√Hz, about 2 orders of magnitude better than requirements. At f ≤ 0.5 mHz we observe a low-frequency tail that stays below 12 fm s−2/√Hz down to 0.1 mHz. This performance would allow for a space-based gravitational wave
observatory with a sensitivity close to what was originally foreseen for LISA
Resample-smoothing of Voronoi intensity estimators
Voronoi estimators are non-parametric and adaptive estimators of the intensity of a point process. The intensity estimate at a given location is equal to the reciprocal of the size of the Voronoi/Dirichlet cell containing that location. Their major drawback is that they tend to paradoxically under-smooth the data in regions where the point density of the observed point pattern is high, and over-smooth where the point density is low. To remedy this behaviour, we propose to apply an additional smoothing operation to the Voronoi estimator, based on resampling the point pattern by independent random thinning. Through a simulation study we show that our resample-smoothing technique improves the estimation substantially. In addition, we study statistical properties such as unbiasedness and variance, and propose a rule-of-thumb and a data-driven cross-validation approach to choose the amount of smoothing to apply. Finally we apply our proposed intensity estimation scheme to two datasets: locations of pine saplings (planar point pattern) and motor vehicle traffic accidents (linear network point pattern)
Biological/Biomedical Accelerator Mass Spectrometry Targets. 1. Optimizing the CO2 Reduction Step Using Zinc Dust
Biological and biomedical applications of accelerator mass spectrometry (AMS) use isotope ratio mass spectrometry to quantify minute amounts of long-lived radioisotopes such as 14C. AMS target preparation involves first the oxidation of carbon (in sample of interest) to CO2 and second the reduction of CO2 to filamentous, fluffy, fuzzy, or firm graphite-like substances that coat a −400-mesh spherical iron powder (−400MSIP) catalyst. Until now, the quality of AMS targets has been variable; consequently, they often failed to produce robust ion currents that are required for reliable, accurate, precise, and high-throughput AMS for biological/biomedical applications. Therefore, we described our optimized method for reduction of CO2 to high-quality uniform AMS targets whose morphology we visualized using scanning electron microscope pictures. Key features of our optimized method were to reduce CO2 (from a sample of interest that provided 1 mg of C) using 100 ± 1.3 mg of Zn dust, 5 ± 0.4 mg of −400MSIP, and a reduction temperature of 500 °C for 3 h. The thermodynamics of our optimized method were more favorable for production of graphite-coated iron powders (GCIP) than those of previous methods. All AMS targets from our optimized method were of 100% GCIP, the graphitization yield exceeded 90%, and δ13C was −17.9 ± 0.3‰. The GCIP reliably produced strong 12C− currents and accurate and precise Fm values. The observed Fm value for oxalic acid II NIST SRM deviated from its accepted Fm value of 1.3407 by only 0.0003 ± 0.0027 (mean ± SE, n = 32), limit of detection of 14C was 0.04 amol, and limit of quantification was 0.07 amol, and a skilled analyst can prepare as many as 270 AMS targets per day. More information on the physical (hardness/color), morphological (SEMs), and structural (FT-IR, Raman, XRD spectra) characteristics of our AMS targets that determine accurate, precise, and high-hroughput AMS measurement are in the companion paper
The association between hip fracture and hip osteoarthritis: A case-control study
<p>Abstract</p> <p>Background</p> <p>There have been reports both supporting and refuting an inverse relationship between hip fracture and hip osteoarthritis (OA). We explore this relationship using a case-control study design.</p> <p>Methods</p> <p>Exclusion criteria were previous hip fracture (same side or contralateral side), age younger than 60 years, foreign nationality, pathological fracture, rheumatoid arthritis and cases were radiographic examinations were not found in the archives. We studied all subjects with hip fracture that remained after the exclusion process that were treated at Akureyri University Hospital, Iceland 1990-2008, n = 562 (74% women). Hip fracture cases were compared with a cohort of subjects with colon radiographs, n = 803 (54% women) to determine expected population prevalence of hip OA. Presence of radiographic hip OA was defined as a minimum joint space of 2.5 mm or less on an anteroposterior radiograph, or Kellgren and Lawrence grade 2 or higher. Possible causes of secondary osteoporosis were identified by review of medical records.</p> <p>Results</p> <p>The age-adjusted odds ratio (OR) for subjects with hip fracture having radiographic hip OA was 0.30 (95% confidence interval [95% CI] 0.12-0.74) for men and 0.33 (95% CI 0.19-0.58) for women, compared to controls. The probability for subjects with hip fracture and hip OA having a secondary cause of osteoporosis was three times higher than for subjects with hip fracture without hip OA.</p> <p>Conclusion</p> <p>The results of our study support an inverse relationship between hip fractures and hip OA.</p
Neuer Kopf, alte Ideen? : "Normalisierung" des Front National unter Marine Le Pen
In this article, it is investigated
whether vibrational entropy
(VE) is an important contribution to the free energy of globular proteins
at ambient conditions. VE represents the major configurational-entropy
contribution of these proteins. By definition, it is an average of
the configurational entropies of the protein within single minima
of the energy landscape, weighted by their occupation probabilities.
Its large part originates from thermal motion of flexible torsion
angles giving rise to the finite peak widths observed in torsion angle
distributions. While VE may affect the equilibrium properties of proteins,
it is usually neglected in numerical calculations as its consideration
is difficult. Moreover, it is sometimes believed that all well-packed
conformations of a globular protein have similar VE anyway. Here, we measure explicitly the VE for six different conformations from simulation data of a test protein. Estimates
are obtained using the quasi-harmonic approximation for three coordinate
sets, Cartesian, bond-angle-torsion (BAT), and a new set termed rotamer-degeneracy
lifted BAT coordinates by us. The new set gives improved estimates
as it overcomes a known shortcoming of the quasi-harmonic approximation
caused by multiply populated rotamer states, and it may serve for
VE estimation of macromolecules in a very general context. The obtained
VE values depend considerably on the type of coordinates used. However,
for all coordinate sets we find large entropy differences between
the conformations, of the order of the overall stability of the protein.
This result may have important implications on the choice of free
energy expressions used in software for protein structure prediction,
protein design, and NMR refinement
- …