120 research outputs found
Measurements of the -Dependence of the Proton and Neutron Spin Structure Functions g1p and g1n
The structure functions g1p and g1n have been measured over the range 0.014 <
x < 0.9 and 1 < Q2 < 40 GeV2 using deep-inelastic scattering of 48 GeV
longitudinally polarized electrons from polarized protons and deuterons. We
find that the Q2 dependence of g1p (g1n) at fixed x is very similar to that of
the spin-averaged structure function F1p (F1n). From a NLO QCD fit to all
available data we find at
Q2=5 GeV2, in agreement with the Bjorken sum rule prediction of 0.182 \pm
0.005.Comment: 17 pages, 3 figures. Submitted to Physics Letters
Measurement of the Proton and Deuteron Spin Structure Functions g2 and Asymmetry A2
We have measured the spin structure functions g2p and g2d and the virtual
photon asymmetries A2p and A2d over the kinematic range 0.02 < x < 0.8 and 1.0
< Q^2 < 30(GeV/c)^2 by scattering 38.8 GeV longitudinally polarized electrons
from transversely polarized NH3 and 6LiD targets.The absolute value of A2 is
significantly smaller than the sqrt{R} positivity limit over the measured
range, while g2 is consistent with the twist-2 Wandzura-Wilczek calculation. We
obtain results for the twist-3 reduced matrix elements d2p, d2d and d2n. The
Burkhardt-Cottingham sum rule integral - int(g2(x)dx) is reported for the range
0.02 < x < 0.8.Comment: 12 pages, 4 figures, 1 tabl
Measurements of the dependence of the proton and neutron spin structure functions and
he structure functions g1p and g1n have been measured over the range 0.014 < x < 0.9 and 1 < Q2 < 40 GeV2 using deep-inelastic scattering of 48 GeV longitudinally polarized electrons from polarized protons and deuterons. We find that the Q2 dependence of g1p (g1n) at fixed x is very similar to that of the spin-averaged structure function F1p (F1n). From a NLO QCD fit to all available data we find at Q2=5 GeV2, in agreement with the Bjorken sum rule prediction of 0.182 \pm 0.005
Inclusive hadron photoproduction from longitudinally polarized protons and deuterons.
We report measurements of the asymmetry A_parallel for inclusive hadron production on longitudinally polarized proton and deuteron targets by circularly polarized photons. The photons were produced via internal and external bremsstrahlung from an electron beam of 48.35 GeV. Asymmetries for both positive and negative signed hadrons, and a subset of identified pions, were measured in the momentum range 1
Precision measurement of the deuteron spin structure function
We report on a high-statistics measurement of the deuteron spin structure function g[sup d][sub 1] at a beam energy of 29 GeV in the kinematic range 0.029 < x < 0.8 and 1 < Q2 < 10 (GeV/c)2. The integral Gamma [sup d][sub 1] = (integral)[sup 1][sub 0]g[sup d][sub 1]dx evaluated at fixed Q2 = 3 (GeV/c)2 gives 0.042 ± 0.003(stat) ± 0.004(syst). Combining this result with our earlier measurement of g[sup p][sub 1], we find Gamma [sup p][sub 1]- Gamma [sup n][sub 1] = 0.163 ± 0.010(stat) ± 0.016(syst), which agrees with the prediction of the Bjorken sum rule with O( alpha [sup 3][sub s]) corrections, Gamma [sup p][sub 1]- Gamma [sup n][sub 1] = 0.171 ± 0.008. We find the quark contribution to the proton helicity to be Delta q = 0.30 ± 0.06
Measurement of the deuteron spin structure function for .
New measurements are reported on the deuteron spin structure function g_1^d. These results were obtained from deep inelastic scattering of 48.3 GeV electrons on polarized deuterons in the kinematic range 0.01 < x < 0.9 and 1 < Q^2 < 40 (GeV/c)^2. These are the first high dose electron scattering data obtained using lithium deuteride (6Li2H) as the target material. Extrapolations of the data were performed to obtain moments of g_1^d, including Gamma_1^d, and the net quark polarization Delta Sigma
Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data
The rapid atmospheric monitoring system of the Pierre Auger Observatory
The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 10(17) eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shortly after the detection of air showers of special interest, e. g., showers produced by very high-energy cosmic rays or showers with atypical longitudinal profiles. The former events are of particular importance for the determination of the energy scale of the Observatory, and the latter are characteristic of unusual air shower physics or exotic primary particle types. The purpose of targeted (or 'rapid') monitoring is to improve the resolution of the atmospheric measurements for such events. In this paper, we report on the implementation of the rapid monitoring program and its current status. The rapid monitoring data have been analyzed and applied to the reconstruction of air showers of high interest, and indicate that the air fluorescence measurements affected by clouds and aerosols are effectively corrected using measurements from the regular atmospheric monitoring program. We find that the rapid monitoring program has potential for supporting dedicated physics analyses beyond the standard event reconstruction
Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors
In a test experiment at the Final Focus Test Beam of the Stanford Linear
Accelerator Center, the fluorescence yield of 28.5 GeV electrons in air and
nitrogen was measured. The measured photon yields between 300 and 400 nm at 1
atm and 29 deg C are Y(760 Torr, air) = 4.42 +/- 0.73 and Y(760 Torr, nitrogen)
= 29.2 +/- 4.8 photons per electron per meter. Assuming that the fluorescence
yield is proportional to the energy deposition of a charged particle traveling
through air, good agreement with measurements at lower particle energies is
observed.Comment: 22 pages, 14 figures, 2 tables, submitted to Astroparticle Physic
Measurements of R=sigma_L/sigma_T for 0.03<x<0.1 and Fit to World Data
Measurements were made at SLAC of the cross section for scattering 29 GeV
electrons from carbon at a laboratory angle of 4.5 degrees, corresponding to
0.03<x<0.1 and 1.3<Q^2<2.7 GeV^2. Values of R=sigma_L/sigma_T were extracted in
this kinematic range by comparing these data to cross sections measured at a
higher beam energy by the NMC collaboration. The results are in reasonable
agreement with pQCD calculations and with extrapolations of the R1990
parameterization of previous data. A new fit is made including these data and
other recent results.Comment: 8 pages, 4 figures, late
- …
