128 research outputs found

    Piet Elling (1897-1962) : een samenstemmende eenheid

    Get PDF

    Dopant-enriched nitrogen gas for enhanced electrospray ionization of released glycans in negative ion mode

    Get PDF
    The desolvation and ionization process of analytes can significantly be improved by enriching the nebulizing gas with a dopant (dopant enriched nitrogen (DEN) gas) in the electrospray source. However, for the analysis of released glycans in negative ion mode, the usage of DEN gas remains largely unexplored. For this purpose, we investigated the effect of different polar protic solvents (methanol, ethanol, and isopropanol) as well as using solely the nebulizing gas or ambient air on the ionization and charge state distribution of released N- and O-glycans. Compared to the standard acetonitrile enriched nitrogen gas, isopropanol showed the highest increase in regards to peak areas. Moreover, it showed large benefits for the identification of glycan structures at high sensitivity as the increased precursor intensities subsequently resulted in higher intensities in tandem MS mode. While similar effects are noted for both neutral and sialylated species, the most significant effect was observed for early eluting glycans where very low acetonitrile concentrations were present in the eluent. The best results in terms of S/N ratios were obtained with methanol, with less effect on the MS/MS signal enhancement. Therefore, the use of this dopant would be particularly beneficial for high sensitivity MS-mode applications. In conclusion, isopropanol enriched DEN gas greatly improves the detection of both N-and O-glycan species and their tandem mass spectra, particularly for the early eluting species whose ionization in the absence of DEN gas is hindered by low organic concentrations.Proteomic

    Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples

    Get PDF
    Introduction: Preanalytical conditions are critical for blood sample integrity and poses challenge in surveys involving biochemical measurements. A cross sectional study was conducted to assess the stability of select biomarkers at conditions that mimic field situations in surveys. Material and methods: Blood from 420 volunteers was exposed to 2 – 8 °C, room temperature (RT), 22 – 30 °C and > 30 °C for 30 min, 6 hours, 12 hours and 24 hours prior to centrifugation. After different exposures, whole blood (N = 35) was used to assess stability of haemoglobin, HbA1c and erythrocyte folate; serum (N = 35) for assessing stability of ferritin, C-reactive protein (CRP), vitamins B12, A and D, zinc, soluble transferrin receptor (sTfR), total cholesterol, high density lipoprotein cholesterol (HDL), low density lipoprotein cholesterol (LDL), tryglicerides, albumin, total protein and creatinine; and plasma (N = 35) was used for glucose. The mean % deviation of the analytes was compared with the total change limit (TCL), computed from analytical and intra-individual imprecision. Values that were within the TCL were deemed to be stable. Result: Creatinine (mean % deviation 14.6, TCL 5.9), haemoglobin (16.4%, TCL 4.4) and folate (33.6%, TCL 22.6) were unstable after 12 hours at 22- 30°C, a temperature at which other analytes were stable. Creatinine was unstable even at RT for 12 hours (mean % deviation: 10.4). Albumin, CRP, glucose, cholesterol, LDL, triglycerides, vitamins B12 and A, sTfR and HbA1c were stable at all studied conditions. Conclusion: All analytes other than creatinine, folate and haemoglobin can be reliably estimated in blood samples exposed to 22-30°C for 12 hours in community-based studies

    Integrated multisectoral strategy to improve girls' and women's nutrition before conception, during pregnancy and after birth in India (Swabhimaan): protocol for a prospective, non-randomised controlled evaluation

    Get PDF
    INTRODUCTION: Swabhimaan is a community-based programme to improve adolescent girls’ and women’s nutrition in the rural areas of three Indian states—Bihar, Chhattisgarh and Odisha with high prevalence of undernutrition. METHODS AND ANALYSIS: Swabhimaan has a nested prospective, non-randomised controlled evaluation. Since 2017, five intervention sites receive community-led interventions through national government’s livelihood mission supported women’s self-help group federations and five control sites will initiate these activities 36 months later, in 2020. Community-led activities aim to improve coverage of 18 interventions including adequacy of food consumed, prevention of micronutrient deficiencies, access to basic health services and special care of nutritionally ‘at risk’ girls and women, improving hygiene and access to water and sanitation services and access to family planning services. The evaluation includes baseline (2016–2017), midline (2018–2019) and endline (2020–2021) surveys covering 6638 adolescent girls, 2992 pregnant women and 8755 mothers of children under 2. The final impact analysis will be by intention to treat, comparing primary and secondary outcomes in five intervention areas and five control areas. The primary outcomes are: (1) a 15% reduction in the proportion of adolescent girls with a body mass index (BMI) <18.5 kg/m2; (2) a 15% reduction in the proportion of mothers of children under two with a BMI <18.5 kg/m2 and (3) and a 0.4 cm improvement in mean mid-upper arm circumference among pregnant women. ETHICS AND DISSEMINATION: All procedures involving human subjects were approved by the Institutional Ethics Committee of the All India Institute of Medical Sciences, Bihar, Chhattisgarh and Odisha and in compliance with guidelines laid down in the Declaration of Helsinki. Evidence will inform maternal and preconception nutrition policy at national and state level. TRIAL REGISTRATION NUMBER: 58261b2f46876 and CTRI/2016/11/007482; Pre-results

    Problems in obtaining precise and accurate Sr isotope analysis from geological materials using laser ablation MC-ICPMS

    Get PDF
    This paper reviews the problems encountered in eleven studies of Sr isotope analysis using laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) in the period 1995–2006. This technique has been shown to have great potential, but the accuracy and precision are limited by: (1) large instrumental mass discrimination, (2) laser-induced isotopic and elemental fractionations and (3) molecular interferences. The most important isobaric interferences are Kr and Rb, whereas Ca dimer/argides and doubly charged rare earth elements (REE) are limited to sample materials which contain substantial amounts of these elements. With modern laser (193 nm) and MC-ICPMS equipment, minerals with >500 ppm Sr content can be analysed with a precision of better than 100 ppm and a spatial resolution (spot size) of approximately 100 Όm. The LA MC-ICPMS analysis of 87Sr/86Sr of both carbonate material and plagioclase is successful in all reported studies, although the higher 84Sr/86Sr ratios do suggest in some cases an influence of Ca dimer and/or argides. High Rb/Sr (>0.01) materials have been successfully analysed by carefully measuring the 85Rb/87Rb in standard material and by applying the standard-sample bracketing method for accurate Rb corrections. However, published LA-MC-ICPMS data on clinopyroxene, apatite and sphene records differences when compared with 87Sr/86Sr measured by thermal ionisation mass spectrometry (TIMS) and solution MC-ICPMS. This suggests that further studies are required to ensure that the most optimal correction methods are applied for all isobaric interferences
    • 

    corecore