73 research outputs found

    Magnetic Resonance Imaging for the in Vivo Evaluation of Gastric-Retentive Tablets

    Get PDF
    Purpose. To develop a magnetic resonance imaging (MRI) technique for assessing in vivo properties of orally ingested gastric-retentive tablets under physiologic conditions. Methods. Tablets with different floating characteristics (tablet A-C) were marked with superparamagnetic Fe3O4 particles to analyze intragastric tablet position and residence time in human volunteers. Optimal Fe3O4 concentration was determined in vitro. Intragastric release characteristic of one slow-release tablet (tablet D) was analyzed by embedding gadolinium chelates (Gd-DOTA) as a drug model into the tablet. All volunteers underwent MRI in the sitting position. Tablet performance was analyzed in terms of relative position of tablet to intragastric meal level (with 100% at meal surface), intragastric residence time (min) and Gd-DOTA distribution volume (% of meal volume). Results. Intragastric tablet floating performance and residence time of tablets (tablet A-D) as well as the intragastric Gd-DOTA distribution of tablet D could be monitored using MRI. Tablet floating performance was different between the tablets (A, 93%(95 − 9%); B, 80%(80 − 68%); C, 38%(63 − 32%); p < 0.05). The intragastric distribution volume of Gd-DOTA was 19.9% proximally and 35.5% distally. Conclusions. The use of MRI allows the assessment of galenic properties of orally ingested tablets in humans in seated positio

    Effects of posture on the physiology of gastric emptying: a magnetic resonance imaging study

    Full text link
    The stomach maintains the rate of gastric emptying despite radical changes in body position and intragastric distribution of gastric contents. In SP, hydrostatic pressure (modulated by gastric tone) dictates the gastric emptying. In UDP, gastric emptying also appears to be mediated by continuous adaptation of gastric tone. These findings provide support for the hypothesis that the mechanism of gastric emptying resembles a "pressure pump" rather than a "peristaltic pump"

    Magnetic resonance imaging for the in vivo evaluation of gastric-retentive tablets

    Full text link
    The use of MRI allows the assessment of galenic properties of orally ingested tablets in humans in seated position

    Exploring gastrointestinal variables affecting drug and formulation behavior: methodologies, challenges and opportunities

    Get PDF
    Various gastrointestinal (GI) factors affect drug and formulation behavior after oral administration, including GI transfer, motility, pH and GI fluid volume and composition. An in-depth understanding of these physiological and anatomical variables is critical for a continued progress in oral drug development. In this review, different methodologies (invasive versus non-invasive) to explore the impact of physiological variables on formulation behavior in the human GI tract are presented, revealing their strengths and limitations. The techniques mentioned allow for an improved understanding of the role of following GI variables: gastric emptying (magnetic resonance imaging (MRI), scintigraphy, acetaminophen absorption technique, ultrasonography, breath test, intraluminal sampling and telemetry), motility (MRI, small intestinal/colonic manometry and telemetry), GI volume changes (MRI and ultrasonography), temperature (telemetry) and intraluminal pH (intraluminal sampling and telemetry)

    Determinants of fecal continence in healthy, continent subjects: a comprehensive analysis by anal manometry, rectal barostat and a stool substitute retention test

    Full text link
    BACKGROUND/AIMS: This study aimed to identify anal sphincter and rectal factors that determine anorectal filling sensations and continence during rectal filling in health. METHODS: Measurements of anorectal physiology were collected from 42 continent healthy subjects participating in a prospective trial. Rectal function and capacity were assessed by barostat. Anal sphincter functions were assessed by manometry. A validated stool substitute retention test was performed in which a viscous suspension was infused into the rectum at 60 ml/min to 1,500 ml. Multivariate regression was applied to identify physiologic factors that determine anorectal sensation and continence during rectal filling. RESULTS: The volume at which first awareness of rectal filling occurred associated with age (p < 0.03), rectal capacity (p < 0.06) and anal resting pressure (p < 0.003); urgency associated with rectal capacity (p < 0.0007), anal resting (p < 0.04) and squeeze pressure (p < 0.02); volume at first incontinence with rectal capacity (p < 0.0001) and squeeze pressure (p < 0.04) and the maximum volume retained were closely correlated with rectal capacity only (p < 0.0001). CONCLUSION: Anorectal filling sensations and continence in health require a rectal reservoir of adequate capacity and effective voluntary anal sphincter function. Complementary associations between continence, motor and sensory function indicate the presence of an adaptive mechanism that enables timely, appropriate responses to events that threaten fecal continence

    19F MR Imaging Golden Angle-based Capsule Tracking for Intestinal Transit and Catheter Tracking: Initial in Vivo Experience

    Full text link
    Purpose:To combine fluorine 19 ((19)F) magnetic resonance (MR) imaging and golden angle radial acquisition and to assess the feasibility of (19)F MR imaging golden angle-based tracking for catheter tracking applications and simultaneous three-dimensional (3D) intestinal tracking of ingested (19)F-labeled capsules in vivo.Materials and Methods:Approval from the local ethical committee and informed consent from the subject were obtained. In vitro studies were performed to assess (19)F MR imaging golden angle-based tracking reliability with regard to temporal resolution and different tracking strategies (boundary condition-free tracking, composite image-based tracking, and model-based tracking). In vivo performance of the method was investigated in one healthy volunteer on 2 days. On study day 1, a duodenal catheter incorporating five (19)F-labeled capsules was administered nasally, and its 3D movement was tracked inside the stomach and esophagus. On study day 2, three (19)F-labeled capsules were swallowed, and intestinal movement was tracked.Results:Simultaneous in vivo 3D tracking of multiple (19)F-labeled capsules was successfully performed without incorporation of boundary conditions at a temporal resolution of 252 msec. Incorporation of boundary conditions with composite image-based tracking and model-based tracking increased tracking reliability and enabled temporal resolution as high as 108 msec.Conclusion:Use of (19)F MR imaging golden angle-based capsule tracking enables in vivo tracking of (19)F-labeled capsules and catheters at high temporal resolution. The presented method is applicable to physioanatomic studies of the gastrointestinal tract and shows potential for real-time tracking in interventional radiology.© RSNA, 2012

    Validation of a Golden Angle Radial Sequence (GOLD) for Abdominal T1 Mapping During Free Breathing: Demonstrating Clinical Feasibility for Quantifying Gastric Secretion and Emptying

    Full text link
    Purpose To validate a magnetic resonance imaging sequence suitable for quantitative assessment of acid suppression by a proton pump inhibitor (PPI) on gastric secretion and emptying in clinical practice. Methods A golden angle radial sequence (GOLD) was validated in a series of in vitro and in vivo experiments and clinical feasibility was shown in two studies. The impact of free breathing and image plane orientation on T1 values was evaluated in a controlled in vivo experiment. The free-breathing GOLD sequence was compared against a standard breath-hold gradient echo sequence for gastric half emptying time in 23 subjects during a gastric emptying study. Pilot data from five subjects assessed the sensitivity of the GOLD sequence to detect changes in acid secretion volume produced by PPI treatment. Results The coronal free-breathing GOLD sequence and the axial breath-hold standard gradient echo sequence showed good agreement of the gastric half emptying time (6 ± 3 min, P = 0.053). The GOLD sequence demonstrated sensitivity to reduction of gastric secretion volumes induced by PPI treatment (55 ± 5 mL, P < 0.001). Conclusion The GOLD sequence allowed for free breathing, multislice, combined imaging and T1 mapping of the stomach content. GOLD presents a promising multipurpose, noninvasive imaging tool for monitoring gastric function in clinical studies
    • …
    corecore