96 research outputs found

    Asymmetric masks for laboratory-based X-ray phase-contrast imaging with edge illumination

    Get PDF
    We report on an asymmetric mask concept that enables X-ray phase-contrast imaging without requiring any movement in the system during data acquisition. The method is compatible with laboratory equipment, namely a commercial detector and a rotating anode tube. The only motion required is that of the object under investigation which is scanned through the imaging system. Two proof-of-principle optical elements were designed, fabricated and experimentally tested. Quantitative measurements on samples of known shape and composition were compared to theory with good agreement. The method is capable of measuring the attenuation, refraction and (ultra-small-angle) X-ray scattering, does not have coherence requirements and naturally adapts to all those situations in which the X-ray image is obtained by scanning a sample through the imaging system

    Multimodal Phase-Based X-Ray Microtomography with Nonmicrofocal Laboratory Sources

    Get PDF
    We present an alternative laboratory implementation of x-ray phase-contrast tomography through a beam-tracking approach. A nonmicrofocal rotating anode source is combined with a high-resolution detector and an absorbing mask to obtain attenuation, phase, and ultra-small-angle scattering tomograms of different specimens. A theoretical model is also presented which justifies the implementation of beam tracking with polychromatic sources and provides quantitative values of attenuation and phase, under the assumption of low sample attenuation. The method is tested on a variety of samples featuring both large and small x-ray attenuation, phase, and scattering signals. The complementarity of the contrast channels can enable subtle distinctions between materials and tissue types, which appear indistinguishable to conventional tomography scanners

    Study on the uncertainty of passive area dosimetry systems for environmental radiation monitoring in the framework of the EMPIR "Preparedness" project

    Get PDF
    Abstract One of the objectives of the EMPIR project 16ENV04 "Preparedness" is the harmonization of methodologies for the measurement of doses with passive dosimetry systems for environmental radiation monitoring in the aftermath of a nuclear or radiological event. In such cases, measurements are often performed at low radiation dose rates, close to the detection limit of the passive systems. The parameters which may affect the dosimetric results of a passive dosimetry system are analyzed and four laboratories quantitatively evaluate the uncertainties of their passive dosimetry systems. Typical uncertainties of five dosimetric systems in four European countries are compared and the main sources of uncertainty are analyzed using the results of a questionnaire compiled for this specific purpose. To compute the characteristic limits of a passive dosimetry system according to standard ISO 11929, the study of the uncertainty of the system is the first step. In this work the uncertainty budget as well as the characteristic limits (decision thresholds and detection limits) are evaluated and the limitations and strengths of a complete analysis of all parameters are presented

    Automation of one-loop QCD corrections

    Get PDF
    We present the complete automation of the computation of one-loop QCD corrections, including UV renormalization, to an arbitrary scattering process in the Standard Model. This is achieved by embedding the OPP integrand reduction technique, as implemented in CutTools, into the MadGraph framework. By interfacing the tool so constructed, which we dub MadLoop, with MadFKS, the fully automatic computation of any infrared-safe observable at the next-to-leading order in QCD is attained. We demonstrate the flexibility and the reach of our method by calculating the production rates for a variety of processes at the 7 TeV LHC.Comment: 64 pages, 12 figures. Corrected the value of m_Z in table 1. In table 2, corrected the values of cross sections in a.4 and a.5 (previously computed with mu=mtop/2 rather than mu=mtop/4). In table 2, corrected the values of NLO cross sections in b.3, b.6, c.3, and e.7 (the symmetry factor for a few virtual channels was incorrect). In sect. A.4.3, the labeling of the four-momenta was incorrec

    A compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast

    Get PDF
    A significant number of patients receiving breast-conserving surgery (BCS) for invasive carcinoma and ductal carcinoma in situ (DCIS) may need reoperation following tumor-positive margins from final histopathology tests. All current intraoperative margin assessment modalities have specific limitations. As a first step towards the development of a compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast, we prove that the system\u27s dimensions can be reduced without affecting imaging performance. We analysed the variation in noise and contrast to noise ratio (CNR) with decreasing system length using the edge illumination x-ray phase contrast imaging setup. Two-(planar) and three-(computed tomography (CT)) dimensional imaging acquisitions of custom phantoms and a breast tissue specimen were made. Dedicated phase retrieval algorithms were used to separate refraction and absorption signals. A \u27single-shot\u27 retrieval method was also used, to retrieve thickness map images, due to its simple acquisition procedure and reduced acquisition times. Experimental results were compared to numerical simulations where appropriate. The relative contribution of dark noise signal in integrating detectors is significant for low photon count statistics acquisitions. Under constant exposure factors and magnification, a more compact system provides an increase in CNR. Superior CNR results were obtained for refraction and thickness map images when compared to absorption images. Results indicate that the \u27single-shot\u27 acquisition method is preferable for a compact CT intraoperative specimen scanner; it allows for shorter acquisition times and its combination of the absorption and refraction signals ultimately leads to a higher contrast. The first CT images of a breast specimen acquired with the compact system provided promising results when compared to those of the longer length system

    An astronomically dated record of Earth's climate and its predictability over the last 66 million years.

    Get PDF
    Much of our understanding of Earth's past climate comes from the measurement of oxygen and carbon isotope variations in deep-sea benthic foraminifera. Yet, long intervals in existing records lack the temporal resolution and age control needed to thoroughly categorize climate states of the Cenozoic era and to study their dynamics. Here, we present a new, highly resolved, astronomically dated, continuous composite of benthic foraminifer isotope records developed in our laboratories. Four climate states-Hothouse, Warmhouse, Coolhouse, Icehouse-are identified on the basis of their distinctive response to astronomical forcing depending on greenhouse gas concentrations and polar ice sheet volume. Statistical analysis of the nonlinear behavior encoded in our record reveals the key role that polar ice volume plays in the predictability of Cenozoic climate dynamics

    18F-fluoro-deoxy-glucose focal uptake in very small pulmonary nodules: fact or artifact? Case reports

    Get PDF
    ABSTRACT: BACKGROUND: F-fluoro-deoxy-glucose (18F-FDG) positron emission tomography integrated/combined with computed tomography (PET-CT) provides the best diagnostic results in the metabolic characterization of undetermined solid pulmonary nodules. The diagnostic performance of 18F-FDG is similar for nodules measuring at least 1 cm and for larger masses, but few data exist for nodules smaller than 1 cm. CASE PRESENTATION: We report five cases of oncologic patients showing focal lung 18F-FDG uptake on PET-CT in nodules smaller than 1 cm. We also discuss the most common causes of 18F-FDG false-positive and false-negative results in the pulmonary parenchyma. In patient 1, contrast-enhanced CT performed 10 days before PET-CT did not show any abnormality in the site of uptake; in patient 2, high-resolution CT performed 1 month after PET showed a bronchiole filled with dense material interpreted as a mucoid impaction; in patient 3, contrast-enhanced CT performed 15 days before PET-CT did not identify any nodules; in patients 4 and 5, contrast-enhanced CT revealed a nodule smaller than 1 cm which could not be characterized. The 18F-FDG uptake at follow-up confirmed the malignant nature of pulmonary nodules smaller than 1 cm which were undetectable, misinterpreted, not recognized or undetermined at contrast-enhanced CT. CONCLUSION: In all five oncologic patients, 18F-FDG was able to metabolically characterize as malignant those nodules smaller than 1 cm, underlining that: 18F-FDG uptake is not only a function of tumor size but it is strongly related to the tumor biology; functional alterations may precede morphologic abnormalities. In the oncologic population, especially in higher-risk patients, PET can be performed even when the nodules are smaller than 1 cm, because it might give an earlier characterization and, sometimes, could guide in the identification of alterations missed on CT

    A compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast

    Get PDF
    “This is an author-created, un-copyedited version of an article accepted for publication/published in Physics in Medicine & Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1361-6560/ab4912

    The impact of immediate breast reconstruction on the time to delivery of adjuvant therapy: the iBRA-2 study

    Get PDF
    Background: Immediate breast reconstruction (IBR) is routinely offered to improve quality-of-life for women requiring mastectomy, but there are concerns that more complex surgery may delay adjuvant oncological treatments and compromise long-term outcomes. High-quality evidence is lacking. The iBRA-2 study aimed to investigate the impact of IBR on time to adjuvant therapy. Methods: Consecutive women undergoing mastectomy ± IBR for breast cancer July–December, 2016 were included. Patient demographics, operative, oncological and complication data were collected. Time from last definitive cancer surgery to first adjuvant treatment for patients undergoing mastectomy ± IBR were compared and risk factors associated with delays explored. Results: A total of 2540 patients were recruited from 76 centres; 1008 (39.7%) underwent IBR (implant-only [n = 675, 26.6%]; pedicled flaps [n = 105,4.1%] and free-flaps [n = 228, 8.9%]). Complications requiring re-admission or re-operation were significantly more common in patients undergoing IBR than those receiving mastectomy. Adjuvant chemotherapy or radiotherapy was required by 1235 (48.6%) patients. No clinically significant differences were seen in time to adjuvant therapy between patient groups but major complications irrespective of surgery received were significantly associated with treatment delays. Conclusions: IBR does not result in clinically significant delays to adjuvant therapy, but post-operative complications are associated with treatment delays. Strategies to minimise complications, including careful patient selection, are required to improve outcomes for patients