143 research outputs found

    Impact of minimal residual disease detection by next-generation flow cytometry in multiple myeloma patients with sustained complete remission after frontline therapy

    Get PDF
    Minimal residual disease (MRD) was monitored in 52 patients with sustained CR (≥2 years) after frontline therapy using next-generation flow (NGF) cytometry. 25% of patients initially MRD- reversed to MRD+. 56% of patients in sustained CR were MRD+; 45% at the level of 10−5; 17% at 10−6. All patients who relapsed during follow-up were MRD+ at the latest MRD assessment, including those with ultra-low tumor burden. MRD persistence was associated with specific phenotypic profiles: higher erythroblasts’ and tumor-associated monocytes/macrophages’ predominance in the bone marrow niche. NGF emerges as a suitable method for periodic, reproducible, highly-sensitive MRD-detection at the level of 10−6

    Reliability, validity and psychometric properties of the Greek translation of the Major Depression Inventory

    Get PDF
    BACKGROUND: The Major Depression Inventory (MDI) is a brief self-rating scale for the assessment of depression. It is reported to be valid because it is based on the universe of symptoms of DSM-IV and ICD-10 depression. The aim of the current preliminary study was to assess the reliability, validity and psychometric properties of the Greek translation of the MDI. METHODS: 30 depressed patients of mean age 23.41 (± 5.77) years, and 68 controls patients of mean age 25.08 (± 11.42) years, entered the study. In 18 of them, the instrument was re-applied 1–2 days later and the Translation and Back Translation made. Clinical diagnosis was reached with the use of the SCAN v.2.0 and the International Personality Disorders Examination (IPDE). The Center for Epidemiological Studies-Depression (CES-D) and the Zung Depression Rating Scale (ZDRS) were applied for cross-validation purposes. Statistical analysis included ANOVA, the Spearman Product Moment Correlation Coefficient, Principal Components Analysis and the calculation of Cronbach's α. RESULTS: Sensitivity and specificity were 0.86 and 0.94, respectively, at 26/27. Cronbach's α for the total scale was equal to 0.89. The Spearman's rho between MDI and CES-D was 0.86 and between MDI and ZDRS was 0.76. The factor analysis revealed two factors but the first accounted for 54% of variance while the second only for 9%. The test-retest reliability was excellent (Spearman's rho between 0.53 and 0.96 for individual items and 0.89 for total score). CONCLUSION: The current study provided preliminary evidence concerning the reliability and validity of the Greek translation of the MDI. Its properties are similar to those reported in the international literature, but further research is necessary

    More things in Heaven and Earth: spirit possession, mental disorder, and intentionality

    Get PDF
    Spirit possession is a common phenomenon around the world in which a non-corporeal agent is involved with a human host. This manifests in a range of maladies or in displacement of the host's agency and identity. Prompted by engagement with the phenomenon in North Africa, this paper draws connections between spirit possession, and the concepts of personhood and intentionality. It employs these concepts to articulate spirit possession, while also developing the intentional stance as formulated by Daniel Dennett. It argues for an understanding of spirit possession as the spirit stance: an intentional strategy that aims at predicting and explaining behaviour by ascribing to an agent (the spirit) beliefs and desires, but is only deployed once the mental states and activity of the subject (the person) fail specific normative distinctions. Applied to behaviours which are generally taken to signal mental disorder, the spirit stance preserves a peculiar form of intentionality where behaviour would otherwise be explained as a consequence of a malfunctioning physical mechanism. Centuries before the modern disciplines of psychoanalysis and phenomenological-psychopathology endeavoured to restore meaning to 'madness', the social institution of spirit possession had been preserving the intentionality of socially deviant behaviour

    Parasympathetic nervous system dysfunction, as identified by pupil light reflex, and its possible connection to hearing impairment

    Get PDF
    Context Although the pupil light reflex has been widely used as a clinical diagnostic tool for autonomic nervous system dysfunction, there is no systematic review available to summarize the evidence that the pupil light reflex is a sensitive method to detect parasympathetic dysfunction. Meanwhile, the relationship between parasympathetic functioning and hearing impairment is relatively unknown. Objectives To 1) review the evidence for the pupil light reflex being a sensitive method to evaluate parasympathetic dysfunction, 2) review the evidence relating hearing impairment and parasympathetic activity and 3) seek evidence of possible connections between hearing impairment and the pupil light reflex. Methods Literature searches were performed in five electronic databases. All selected articles were categorized into three sections: pupil light reflex and parasympathetic dysfunction, hearing impairment and parasympathetic activity, pupil light reflex and hearing impairment. Results Thirty-eight articles were included in this review. Among them, 36 articles addressed the pupil light reflex and parasympathetic dysfunction. We summarized the information in these data according to different types of parasympathetic-related diseases. Most of the studies showed a difference on at least one pupil light reflex parameter between patients and healthy controls. Two articles discussed the relationship between hearing impairment and parasympathetic activity. Both studies reported a reduced parasympathetic activity in the hearing impaired groups. The searches identified no results for pupil light reflex and hearing impairment. Discussion and Conclusions As the first systematic review of the evidence, our findings suggest that the pupil light reflex is a sensitive tool to assess the presence of parasympathetic dysfunction. Maximum constriction velocity and relative constriction amplitude appear to be the most sensitive parameters. There are only two studies investigating the relationship between parasympathetic activity and hearing impairment, hence further research is needed. The pupil light reflex could be a candidate measurement tool to achieve this goal

    Identifying energy model fingerprints in mitigation scenarios

    Get PDF
    Energy models are used to study emissions mitigation pathways, such as those compatible with the Paris Agreement goals. These models vary in structure, objectives, parameterization and level of detail, yielding differences in the computed energy and climate policy scenarios. To study model differences, diagnostic indicators are common practice in many academic fields, for example, in the physical climate sciences. However, they have not yet been applied systematically in mitigation literature, beyond addressing individual model dimensions. Here we address this gap by quantifying energy model typology along five dimensions: responsiveness, mitigation strategies, energy supply, energy demand and mitigation costs and effort, each expressed through several diagnostic indicators. The framework is applied to a diagnostic experiment with eight energy models in which we explore ten scenarios focusing on Europe. Comparing indicators to the ensemble yields comprehensive ‘energy model fingerprints’, which describe systematic model behaviour and contextualize model differences for future multi-model comparison studies

    Detection potential of the KM3NeT detector for high-energy neutrinos from the Fermi bubbles

    Get PDF
    A recent analysis of the Fermi Large Area Telescope data provided evidence for a high-intensity emission of high-energy gamma rays with a E 2 spectrum from two large areas, spanning 50 above and below the Galactic centre (the ‘‘Fermi bubbles’’). A hadronic mechanism was proposed for this gamma-ray emission making the Fermi bubbles promising source candidates of high-energy neutrino emission. In this work Monte Carlo simulations regarding the detectability of high-energy neutrinos from the Fermi bubbles with the future multi-km3 neutrino telescope KM3NeT in the Mediterranean Sea are presented. Under the hypothesis that the gamma-ray emission is completely due to hadronic processes, the results indicate that neutrinos from the bubbles could be discovered in about one year of operation, for a neutrino spectrum with a cutoff at 100 TeV and a detector with about 6 km3 of instrumented volume. The effect of a possible lower cutoff is also considered.Published7–141.8. Osservazioni di geofisica ambientaleJCR Journalrestricte

    Expansion cone for the 3-inch PMTs of the KM3NeT optical modules

    Full text link
    [EN] Detection of high-energy neutrinos from distant astrophysical sources will open a new window on the Universe. The detection principle exploits the measurement of Cherenkov light emitted by charged particles resulting from neutrino interactions in the matter containing the telescope. A novel multi-PMT digital optical module (DOM) was developed to contain 31 3-inch photomultiplier tubes (PMTs). In order to maximize the detector sensitivity, each PMT will be surrounded by an expansion cone which collects photons that would otherwise miss the photocathode. Results for various angles of incidence with respect to the PMT surface indicate an increase in collection efficiency by 30% on average for angles up to 45 degrees with respect to the perpendicular. Ray-tracing calculations could reproduce the measurements, allowing to estimate an increase in the overall photocathode sensitivity, integrated over all angles of incidence, by 27% (for a single PMT). Prototype DOMs, being built by the KM3NeT consortium, will be equipped with these expansion cones.This work is supported through the EU, FP6 Contract no. 011937, FP7 grant agreement no. 212252, and the Dutch Ministry of Education, Culture and Science.Adrián Martínez, S.; Ageron, M.; Aguilar, JA.; Aharonian, F.; Aiello, S.; Albert, A.; Alexandri, M.... (2013). Expansion cone for the 3-inch PMTs of the KM3NeT optical modules. Journal of Instrumentation. 8(3):1-19. https://doi.org/10.1088/1748-0221/8/03/T03006S1198
    corecore