231 research outputs found
Recommended from our members
Stability of optical elements in the NIF target area building
The Target Area Building (TAB) of the National Ignition Facility (NIF) is 300 feet long, 100 feet wide, and 100 feet tall and is comprised of a cylindrical target building and two switchyard space frames. The reinforced concrete target building houses the target chamber, target positioner, turning mirrors, final optics assemblies, and diagnostics, while the steel switchyard space frames support turning mirrors and diagnostic equipment. Within the TAB, the 192 independent laser beams of the NIF laser system are required to be accurately positioned. In order to satisfy the engineering system requirement for optical system positioning (stability on target), the TAB must provide a stable platform for optical elements before and during a shot. This paper summarizes the stability analyses that were performed in support of the TAB and optical system design. Sources that influence optic stability are structural excitations, such as ambient and wind induced vibrations, and thermal transients, such as diurnal and HVAC temperature changes. A positioning error budget has been developed for the NIF project for use in the design and evaluation of structures which support optical elements. To satisfy the error budget requirements, vibrational stability will be achieved through a combination of facility design, optic support structure design, and passive damping. Thermal stability will be accomplished by using high thermal-mass concrete structures, conditioned air flow, and a reduction of heat sources. Finite element analysis has been used to evaluate the design of the TAB and optical support structures. A detailed structural model of the TAB that includes the target positioner, target chamber, turning mirrors, and diagnostics, has been used for stability evaluations. Finite element analyses covering ambient ground vibration, thermal loads, pressure fluctuations, and wind excitations have demonstrated that the current design of the TAB provides a stable platform for maintaining beam alignment
Recommended from our members
CASKS (Computer Analysis of Storage casKS): A microcomputer based analysis system for storage cask design review. User`s manual to Version 1b (including program reference)
CASKS (Computer Analysis of Storage casKS) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for evaluating safety analysis reports on spent-fuel storage casks. The bulk of the complete program and this user`s manual are based upon the SCANS (Shipping Cask ANalysis System) program previously developed at LLNL. A number of enhancements and improvements were added to the original SCANS program to meet requirements unique to storage casks. CASKS is an easy-to-use system that calculates global response of storage casks to impact loads, pressure loads and thermal conditions. This provides reviewers with a tool for an independent check on analyses submitted by licensees. CASKS is based on microcomputers compatible with the IBM-PC family of computers. The system is composed of a series of menus, input programs, cask analysis programs, and output display programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests
Directional limits on persistent gravitational waves using LIGO S5 science data
The gravitational-wave (GW) sky may include nearby pointlike sources as well
as astrophysical and cosmological stochastic backgrounds. Since the relative
strength and angular distribution of the many possible sources of GWs are not
well constrained, searches for GW signals must be performed in a
model-independent way. To that end we perform two directional searches for
persistent GWs using data from the LIGO S5 science run: one optimized for
pointlike sources and one for arbitrary extended sources. The latter result is
the first of its kind. Finding no evidence to support the detection of GWs, we
present 90% confidence level (CL) upper-limit maps of GW strain power with
typical values between 2-20x10^-50 strain^2 Hz^-1 and 5-35x10^-49 strain^2
Hz^-1 sr^-1 for pointlike and extended sources respectively. The limits on
pointlike sources constitute a factor of 30 improvement over the previous best
limits. We also set 90% CL limits on the narrow-band root-mean-square GW strain
from interesting targets including Sco X-1, SN1987A and the Galactic Center as
low as ~7x10^-25 in the most sensitive frequency range near 160 Hz. These
limits are the most constraining to date and constitute a factor of 5
improvement over the previous best limits.Comment: 10 pages, 4 figure
Sensitivity to Gravitational Waves from Compact Binary Coalescences Achieved during LIGO's Fifth and Virgo's First Science Run
We summarize the sensitivity achieved by the LIGO and Virgo gravitational
wave detectors for compact binary coalescence (CBC) searches during LIGO's
fifth science run and Virgo's first science run. We present noise spectral
density curves for each of the four detectors that operated during these
science runs which are representative of the typical performance achieved by
the detectors for CBC searches. These spectra are intended for release to the
public as a summary of detector performance for CBC searches during these
science runs.Comment: 12 pages, 5 figure
Recommended from our members
10-kJ Status and 100-kJ Future for NIF PetaWatt Technology
We discuss the status of the NIF ARC, an 8-beam 10-kJ class high-energy petawatt laser, and the future upgrade path of this and similar systems to 100-kJ-class with coherent phasing of multiple apertures
Mental health care for irregular migrants in Europe: Barriers and how they are overcome
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use,
distribution, and reproduction in any medium, provided the original work is properly cited
Virgo calibration and reconstruction of the gravitational wave strain during VSR1
Virgo is a kilometer-length interferometer for gravitational waves detection
located near Pisa. Its first science run, VSR1, occured from May to October
2007. The aims of the calibration are to measure the detector sensitivity and
to reconstruct the time series of the gravitational wave strain h(t). The
absolute length calibration is based on an original non-linear reconstruction
of the differential arm length variations in free swinging Michelson
configurations. It uses the laser wavelength as length standard. This method is
used to calibrate the frequency dependent response of the Virgo mirror
actuators and derive the detector in-loop response and sensitivity within ~5%.
The principle of the strain reconstruction is highlighted and the h(t)
systematic errors are estimated. A photon calibrator is used to check the sign
of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz
with systematic errors estimated to 6% in amplitude. The phase error is
estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.Comment: 8 pages, 8 figures, proceedings of Amaldi 8 conference, to be
published in Journal of Physics Conference Series (JPCS). Second release:
correct typo
Global Protection and the Health Impact of Migration Interception
In the fourth article in a six-part PLoS Medicine series on Migration & Health, Zachary Steel and colleagues discuss the interception phase of migration and the specific health risks and policy needs associated with this phase
Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics
The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.http://www.sciencedirect.com/science/article/B6TJM-4M942B5-D/1/e8aea93baa1aeae3538ea200a5a5466
Migrant health in Italy: a better health status difficult to maintain-country of origin and assimilation effects studied from the Italian risk factor surveillance data
Many studies on migrant health have focused on aspects of morbidity and mortality, but very few approach the relevant issues of migrants' health considering behavioral risk factors. Previous studies have often been limited methodologically because of sample size or lack of information on migrant country of origin. Information about risk factors is fundamental to direct any intervention, particularly with regard to non-communicable diseases that are leading causes of death and disease. Thus, the main focus of our analysis is the influence of country of origin and the assimilation process
- …