12 research outputs found
Molecular Imaging of Inflammation - current and emerging technologies for diagnosis and treatment
Inflammation is a key factor in multiple diseases including primary immune-mediated inflammatory diseases e.g. rheumatoid arthritis but also, less obviously, in many other common conditions, e.g. cardiovascular disease and diabetes. Together, chronic inflammatory diseases contribute to the majority of global morbidity and mortality. However, our understanding of the underlying processes by which the immune response is activated and sustained is limited by a lack of cellular and molecular information obtained in situ. Molecular imaging is the visualization, detection and quantification of molecules in the body. The ability to reveal information on inflammatory biomarkers, pathways and cells can improve disease diagnosis, guide and monitor therapeutic intervention and identify new targets for research. The optimum molecular imaging modality will possess high sensitivity and high resolution and be capable of non-invasive quantitative imaging of multiple disease biomarkers while maintaining an acceptable safety profile. The mainstays of current clinical imaging are computed tomography (CT), magnetic resonance imaging (MRI), ultrasound (US) and nuclear imaging such as positron emission tomography (PET). However, none of these have yet progressed to routine clinical use in the molecular imaging of inflammation, therefore new approaches are required to meet this goal. This review sets out the respective merits and limitations of both established and emerging imaging modalities as clinically useful molecular imaging tools in addition to potential theranostic applications
Specific versus General Principles for Constitutional AI
Human feedback can prevent overtly harmful utterances in conversational
models, but may not automatically mitigate subtle problematic behaviors such as
a stated desire for self-preservation or power. Constitutional AI offers an
alternative, replacing human feedback with feedback from AI models conditioned
only on a list of written principles. We find this approach effectively
prevents the expression of such behaviors. The success of simple principles
motivates us to ask: can models learn general ethical behaviors from only a
single written principle? To test this, we run experiments using a principle
roughly stated as "do what's best for humanity". We find that the largest
dialogue models can generalize from this short constitution, resulting in
harmless assistants with no stated interest in specific motivations like power.
A general principle may thus partially avoid the need for a long list of
constitutions targeting potentially harmful behaviors. However, more detailed
constitutions still improve fine-grained control over specific types of harms.
This suggests both general and specific principles have value for steering AI
safely
Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography
<p>Abstract</p> <p>Background</p> <p>Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency.</p> <p>Methods</p> <p>Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography.</p> <p>Results</p> <p>A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography.</p> <p>Conclusion</p> <p>Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.</p
Recommended from our members
Ultrasound-guided targeted biopsies of CT-based radiomic tumour habitats: technical development and initial experience in metastatic ovarian cancer
Funder: Horizon 2020; doi: http://dx.doi.org/10.13039/501100007601Funder: Cancer Research UKFunder: Mark Foundation For Cancer Research; doi: http://dx.doi.org/10.13039/100014599Abstract: Purpose: To develop a precision tissue sampling technique that uses computed tomography (CT)âbased radiomic tumour habitats for ultrasound (US)-guided targeted biopsies that can be integrated in the clinical workflow of patients with high-grade serous ovarian cancer (HGSOC). Methods: Six patients with suspected HGSOC scheduled for US-guided biopsy before starting neoadjuvant chemotherapy were included in this prospective study from September 2019 to February 2020. The tumour segmentation was performed manually on the pre-biopsy contrast-enhanced CT scan. Spatial radiomic maps were used to identify tumour areas with similar or distinct radiomic patterns, and tumour habitats were identified using the Gaussian mixture modelling. CT images with superimposed habitat maps were co-registered with US images by means of a landmark-based rigid registration method for US-guided targeted biopsies. The dice similarity coefficient (DSC) was used to assess the tumour-specific CT/US fusion accuracy. Results: We successfully co-registered CT-based radiomic tumour habitats with US images in all patients. The median time between CT scan and biopsy was 21 days (range 7â30 days). The median DSC for tumour-specific CT/US fusion accuracy was 0.53 (range 0.79 to 0.37). The CT/US fusion accuracy was high for the larger pelvic tumours (DSC: 0.76â0.79) while it was lower for the smaller omental metastases (DSC: 0.37â0.53). Conclusion: We developed a precision tissue sampling technique that uses radiomic habitats to guide in vivo biopsies using CT/US fusion and that can be seamlessly integrated in the clinical routine for patients with HGSOC. Key Points: âą We developed a prevision tissue sampling technique that co-registers CT-based radiomicsâbased tumour habitats with US images. âą The CT/US fusion accuracy was high for the larger pelvic tumours (DSC: 0.76â0.79) while it was lower for the smaller omental metastases (DSC: 0.37â0.53)
Effects of a high-dose 24-h infusion of tranexamic acid on death and thromboembolic events in patients with acute gastrointestinal bleeding (HALT-IT): an international randomised, double-blind, placebo-controlled trial
Background: Tranexamic acid reduces surgical bleeding and reduces death due to bleeding in patients with trauma.
Meta-analyses of small trials show that tranexamic acid might decrease deaths from gastrointestinal bleeding. We
aimed to assess the effects of tranexamic acid in patients with gastrointestinal bleeding.
Methods: We did an international, multicentre, randomised, placebo-controlled trial in 164 hospitals in 15 countries.
Patients were enrolled if the responsible clinician was uncertain whether to use tranexamic acid, were aged above the
minimum age considered an adult in their country (either aged 16 years and older or aged 18 years and older), and
had significant (defined as at risk of bleeding to death) upper or lower gastrointestinal bleeding. Patients were
randomly assigned by selection of a numbered treatment pack from a box containing eight packs that were identical
apart from the pack number. Patients received either a loading dose of 1 g tranexamic acid, which was added to
100 mL infusion bag of 0·9% sodium chloride and infused by slow intravenous injection over 10 min, followed by a
maintenance dose of 3 g tranexamic acid added to 1 L of any isotonic intravenous solution and infused at 125 mg/h
for 24 h, or placebo (sodium chloride 0·9%). Patients, caregivers, and those assessing outcomes were masked to
allocation. The primary outcome was death due to bleeding within 5 days of randomisation; analysis excluded patients
who received neither dose of the allocated treatment and those for whom outcome data on death were unavailable.
This trial was registered with Current Controlled Trials, ISRCTN11225767, and ClinicalTrials.gov, NCT01658124.
Findings: Between July 4, 2013, and June 21, 2019, we randomly allocated 12 009 patients to receive tranexamic acid
(5994, 49·9%) or matching placebo (6015, 50·1%), of whom 11 952 (99·5%) received the first dose of the allocated
treatment. Death due to bleeding within 5 days of randomisation occurred in 222 (4%) of 5956 patients in the
tranexamic acid group and in 226 (4%) of 5981 patients in the placebo group (risk ratio [RR] 0·99, 95% CI 0·82â1·18).
Arterial thromboembolic events (myocardial infarction or stroke) were similar in the tranexamic acid group and
placebo group (42 [0·7%] of 5952 vs 46 [0·8%] of 5977; 0·92; 0·60 to 1·39). Venous thromboembolic events (deep vein
thrombosis or pulmonary embolism) were higher in tranexamic acid group than in the placebo group (48 [0·8%] of
5952 vs 26 [0·4%] of 5977; RR 1·85; 95% CI 1·15 to 2·98).
Interpretation: We found that tranexamic acid did not reduce death from gastrointestinal bleeding. On the basis of our
results, tranexamic acid should not be used for the treatment of gastrointestinal bleeding outside the context of a
randomised trial
The Elgin marvel: using magnetic resonance imaging to look at a mouldic fossil from the Permian of Elgin, Scotland, UK
The successful use of magnetic resonance imaging (MRI) of a moldic fossil dicynodont from the Permian aeolian Hopeman Sandstone Formation of Elgin, Scotland, UK, provides paleontologists with a nondestructive technique for examining fossils preserved in this fashion. For large moldic fossils, medical scanners such as the Phillips Gyroscan MRI, provide adequate resolution for gross morphologic determination. The 3-D rendered images using software such as Philips Easivision allows the fossil to be examined and dissected without causing any physical damage to the original material. From the scans it is also possible to produce 3-D stereolithographs for a more tactile manipulation of the renderings
Recommended from our members
Ultrasound-guided targeted biopsies of CT-based radiomic tumour habitats: technical development and initial experience in metastatic ovarian cancer
Funder: Horizon 2020; doi: http://dx.doi.org/10.13039/501100007601Funder: Cancer Research UKFunder: Mark Foundation For Cancer Research; doi: http://dx.doi.org/10.13039/100014599Abstract: Purpose: To develop a precision tissue sampling technique that uses computed tomography (CT)âbased radiomic tumour habitats for ultrasound (US)-guided targeted biopsies that can be integrated in the clinical workflow of patients with high-grade serous ovarian cancer (HGSOC). Methods: Six patients with suspected HGSOC scheduled for US-guided biopsy before starting neoadjuvant chemotherapy were included in this prospective study from September 2019 to February 2020. The tumour segmentation was performed manually on the pre-biopsy contrast-enhanced CT scan. Spatial radiomic maps were used to identify tumour areas with similar or distinct radiomic patterns, and tumour habitats were identified using the Gaussian mixture modelling. CT images with superimposed habitat maps were co-registered with US images by means of a landmark-based rigid registration method for US-guided targeted biopsies. The dice similarity coefficient (DSC) was used to assess the tumour-specific CT/US fusion accuracy. Results: We successfully co-registered CT-based radiomic tumour habitats with US images in all patients. The median time between CT scan and biopsy was 21 days (range 7â30 days). The median DSC for tumour-specific CT/US fusion accuracy was 0.53 (range 0.79 to 0.37). The CT/US fusion accuracy was high for the larger pelvic tumours (DSC: 0.76â0.79) while it was lower for the smaller omental metastases (DSC: 0.37â0.53). Conclusion: We developed a precision tissue sampling technique that uses radiomic habitats to guide in vivo biopsies using CT/US fusion and that can be seamlessly integrated in the clinical routine for patients with HGSOC. Key Points: âą We developed a prevision tissue sampling technique that co-registers CT-based radiomicsâbased tumour habitats with US images. âą The CT/US fusion accuracy was high for the larger pelvic tumours (DSC: 0.76â0.79) while it was lower for the smaller omental metastases (DSC: 0.37â0.53)
Combined effects of exploitation and temperature on fish stocks in the Northeast Atlantic
VersiĂłn del editor