36 research outputs found

    Early prenatal diagnosis of conjoined twins at 7 weeks and 6 days' gestation with two-dimensional Doppler ultrasound: a case report

    Get PDF
    This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according to crown-rump length in a 32-year-old Turkish woman, using two-dimensional Doppler ultrasound. The twins were fused to each other at the thoracic region (thoracopagus). In the light of previous reports of conjoined twins this appears to be one of the earliest prenatally diagnosed cases in the medical literature

    Prenatal diagnosis of achondrogenesis type I: a case report

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution Licens

    European Society of Gynaecological Oncology quality indicators for surgical treatment of cervical cancer

    Get PDF
    Background: optimizing and ensuring the quality of surgical care is essential to improve the management and outcome of patients with cervical cancer.To develop a list of quality indicators for surgical treatment of cervical cancer that can be used to audit and improve clinical practice. Methods: quality indicators were developed using a four-step evaluation process that included a systematic literature search to identify potential quality indicators, in-person meetings of an ad hoc group of international experts, an internal validation process, and external review by a large panel of European clinicians and patient representatives. Results: fifteen structural, process, and outcome indicators were selected. Using a structured format, each quality indicator has a description specifying what the indicator is measuring. Measurability specifications are also detailed to define how the indicator will be measured in practice. Each indicator has a target which gives practitioners and health administrators a quantitative basis for improving care and organizational processes. Discussion: implementation of institutional quality assurance programs can improve quality of care, even in high-volume centers. This set of quality indicators from the European Society of Gynaecological Cancer may be a major instrument to improve the quality of surgical treatment of cervical cancer

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Vaginal-assisted laparoscopic nerve sparing radical trachelectomy

    No full text
    Fertility-sparing surgery has gained popularity in the last three decades for the management of cervical cancer in women under 40 years of age. Radical trachelectomy is a fertility-sparing surgical technique for women who wish to retain their fertility. Vaginal-assisted laparoscopic radical trachelectomy is feasible in selected patients with early cervical cancer. The aim of this video is to present a nerve-sparing vaginal-assisted laparoscopic radical trachelectomy demonstrating pelvic anatomical structures

    Failure of sentinel lymph node mapping in a patient with endometrial cancer with chronic lymphocytic leukemia: A case report

    No full text
    We aimed to report a detection failure of sentinel lymph node (SLN) mapping via indocyanine green in a patient with endometrial cancer with a previous history of chronic lymphocytic leukemia (CLL), which is a potential risk factor to obstruct lymphatic channels. A 64-year-old woman with a 12-year history of CLL presented to the clinic with grade 2 endometrioid carcinoma. The patient underwent laparoscopic surgical staging. Indocyanine green was used intraoperatively to locate the SLN. No lymph node or lymphatic vessels were identified during SLN mapping. At the final pathology, the morphological findings of CLL were detected in the lymph nodes without metastasis of endometrial cancer. Sentinel lymph node mapping failure due to obstruction of lymphatic channels in a patient with CLL was demonstrated in this study. This is the first report to the best of our knowledge showing SLN mapping failure in the presence of lymphoproliferative diseases

    Intraoperative endoscopic ultrasound guidance for laparoscopic excision of invisible symptomatic deep intramural myomas

    No full text
    The aim of this study was to evaluate the feasibility of intraoperative endoscopic ultrasound guidance for excision of symptomatic deep intramural myomas that are not otherwise visible at laparoscopy. Seventeen patients with symptomatic deep intramural myomas who underwent laparoscopic myomectomy with intraoperative endoscopic ultrasound guidance were followed up and reported. All myomas were removed successfully. The endometrium was breached in one patient. All patients were relieved of their symptoms and three patients presenting with infertility conceived. There were no short- or long-term complications associated with the procedure. One patient who had multiple myomas necessitated intravenous iron treatment prior to discharge. Laparoscopic removal of small symptomatic deep intramural myomas is facilitated by the use of intraoperative endoscopic ultrasound that enables exact localisation and correct placement of the serosal incision.Impact statement What is already known on this subject: When the myoma is symptomatic, compressing the endometrium, does not show serosal protrusion and is not amenable to hysteroscopic resection, laparoscopic surgery may become challenging. What do the results of this study add: The use of intraoperative endoscopic ultrasound under these circumstances may facilitate the procedure by accurate identification of the myoma and correct placement of the serosal incision. What are the implications of these findings for clinical practice and/or further research: Intraoperative ultrasound should be more oftenly used to accurately locate deep intramural myomas to the end of making laparoscopy feasible and possibly decreasing recurrence by facilitating removal of otherwise unidentifiable disease

    Clermont-Ferrand versus Vectec uterine manipulator for total laparoscopic hysterectomy

    No full text
    <p><b>Objective:</b> To compare the operation time and performance of two uterine manipulators used for total laparoscopic hysterectomy (TLH).</p> <p><b>Material and methods:</b><i>Design:</i> Retrospective cohort analysis. <i>Design classification:</i> Canadian Task Force Classification II-2. <i>Setting:</i> Tertiary-care university-based teaching hospital and academic affiliated private hospital. <i>Patients:</i> All consecutive patients who underwent for TLH between January 2014 and June 2017. All operations were performed by two expert endoscopic surgeons using one of the following uterine manipulators depending on surgeon preferences: Clermont-Ferrand (CF) or Vectec (VT) MAUT60. Patients were excluded if additional surgeries such as urogynecological procedures were performed, TLH was converted to laparotomy prior to colpotomy, and when their operation records could not be obtained. A total of 169 patients were added to final analysis. Operation time, colpotomy time and the subjective performance of manipulators such as movement of the uterus, visualization of the vaginal fornices, and maintenance of pneumoperitoneum were evaluated by watching un-edited operation videos.</p> <p><b>Results:</b> A total of 169 patients (83 patients in CF group; 86 patients in VT group) were included in the final analysis. Patients’ baseline characteristics were comparable between groups. Operation time and time required for colpotomy were significantly shorter in the VT group. Lateral movements of the manipulators and elevation of the uterus were better with VT compared to CF (<i>p</i> = .001 for both). Compared to the CF, VT was superior for visualization of the vaginal fornices (<i>p</i> = .004) and maintenance of pneumoperitoneum (<i>p</i> < .001). Both surgeons had perfect agreement on the performance grading of manipulators (<i>p</i> < .001, Kappa values were between 0.86–0.92). There was no difference between groups in estimated blood loss and duration of hospital stay. Reinsertion or the need to change the manipulator was not required in either group. No pelvic or vaginal abscess, cuff cellulitis, dehiscence, or hematoma formations were noted.</p> <p><b>Conclusion:</b> Laparoscopic hysterectomy assisted with the VT uterine manipulator is associated with shorter operation and colpotomy time. Furthermore, the movements of uterus, visualization of the vaginal fornices, and maintenance of pneumoperitoneum were significantly better with VT compared to the CF manipulator.</p
    corecore