291 research outputs found

    Modelling Techniques for the Quantification of Some Electron Beam Induced Phenomena

    Get PDF
    This paper presents simulation models for quantifying the voltage contrast, cathodoluminescence and indirect specimen charging phenomena in the scanning electron microscope (SEM). The voltage contrast model comprises an electric field computation program using the finite-element approach, and a secondary electron trajectory tracking algorithm employing a linear electric field assumption. This trajectory tracking algorithm is more accurate than the conventional electron trajectory tracking algorithms which make use of a constant electric field assumption within each computation step. Using this model, results of qualitative voltage contrast effects on secondary electron trajectories in the specimen chamber of the SEM are shown. This model can also be used for quantitative voltage studies for designing low error voltage energy analysers. The cathodoluminescence (CL) model consists of programs for simulating the electron beam-specimen interaction via Monte Carlo analysis, excess carrier generation and distribution, and optical losses of the CL emission. This model has been used to simulate the CL intensity as a function of surface recombination velocity, diffusion length, and absorption coefficient. A model has also been developed to simulate indirect charging of specimens in the SEM. This model uses the finite-element method to solve for the self-consistent electric field due to the imposed boundary conditions, trapped and moving charges. Secondary electrons are tracked using the trajectory tracking scheme developed

    Inexperienced clinicians can extract pathoanatomic information from MRI narrative reports with high reproducibility for use in research/quality assurance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although reproducibility in reading MRI images amongst radiologists and clinicians has been studied previously, no studies have examined the reproducibility of inexperienced clinicians in extracting pathoanatomic information from magnetic resonance imaging (MRI) narrative reports and transforming that information into quantitative data. However, this process is frequently required in research and quality assurance contexts. The purpose of this study was to examine inter-rater reproducibility (agreement and reliability) among an inexperienced group of clinicians in extracting spinal pathoanatomic information from radiologist-generated MRI narrative reports.</p> <p>Methods</p> <p>Twenty MRI narrative reports were randomly extracted from an institutional database. A group of three physiotherapy students independently reviewed the reports and coded the presence of 14 common pathoanatomic findings using a categorical electronic coding matrix. Decision rules were developed after initial coding in an effort to resolve ambiguities in narrative reports. This process was repeated a further three times using separate samples of 20 MRI reports until no further ambiguities were identified (total n = 80). Reproducibility between trainee clinicians and two highly trained raters was examined in an arbitrary coding round, with agreement measured using percentage agreement and reliability measured using unweighted Kappa (<it>k</it>). Reproducibility was then examined in another group of three trainee clinicians who had not participated in the production of the decision rules, using another sample of 20 MRI reports.</p> <p>Results</p> <p>The mean percentage agreement for paired comparisons between the initial trainee clinicians improved over the four coding rounds (97.9-99.4%), although the greatest improvement was observed after the first introduction of coding rules. High inter-rater reproducibility was observed between trainee clinicians across 14 pathoanatomic categories over the four coding rounds (agreement range: 80.8-100%; reliability range <it>k </it>= 0.63-1.00). Concurrent validity was high in paired comparisons between trainee clinicians and highly trained raters (agreement 97.8-98.1%, reliability <it>k </it>= 0.83-0.91). Reproducibility was also high in the second sample of trainee clinicians (inter-rater agreement 96.7-100.0% and reliability <it>k </it>= 0.76-1.00; intra-rater agreement 94.3-100.0% and reliability <it>k </it>= 0.61-1.00).</p> <p>Conclusions</p> <p>A high level of radiological training is not required in order to transform MRI-derived pathoanatomic information from a narrative format to a quantitative format with high reproducibility for research or quality assurance purposes.</p

    The foot posture index, ankle lunge test, Beighton scale and the lower limb assessment score in healthy children: a reliability study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Outcome measures are important when evaluating treatments and physiological progress in paediatric populations. Reliable, relevant measures of foot posture are important for such assessments to be accurate over time. The aim of the study was to assess the intra- and inter-rater reliability of common outcome measures for paediatric foot conditions.</p> <p>Methods</p> <p>A repeated measures, same-subject design assessed the intra- and inter-rater reliability of measures of foot posture, joint hypermobility and ankle range: the Foot Posture Index (FPI-6), the ankle lunge test, the Beighton scale and the lower limb assessment scale (LLAS), used by two examiners in 30 healthy children (aged 7 to 15 years). The Oxford Ankle Foot Questionnaire (OxAFQ-C) was completed by participants and a parent, to assess the extent of foot and ankle problems.</p> <p>Results</p> <p>The OxAFQ-C demonstrated a mean (SD) score of 6 (6) in adults and 7(5) for children, showing good agreement between parents and children, and which indicates mid-range (transient) disability. Intra-rater reliability was good for the FPI-6 (ICC = 0.93 - 0.94), ankle lunge test (ICC = 0.85-0.95), Beighton scale (ICC = 0.96-0.98) and LLAS (ICC = 0.90-0.98). Inter-rater reliability was largely good for each of the: FPI-6 (ICC = 0.79), ankle lunge test (ICC = 0.83), Beighton scale (ICC = 0.73) and LLAS (ICC = 0.78).</p> <p>Conclusion</p> <p>The four measures investigated demonstrated adequate intra-rater and inter-rater reliability in this paediatric sample, which further justifies their use in clinical practice.</p

    Toward a better definition of focal cortical dysplasia: An iterative histopathological and genetic agreement trial.

    Get PDF
    OBJECTIVE: Focal cortical dysplasia (FCD) is a major cause of difficult-to-treat epilepsy in children and young adults, and the diagnosis is currently based on microscopic review of surgical brain tissue using the International League Against Epilepsy classification scheme of 2011. We developed an iterative histopathological agreement trial with genetic testing to identify areas of diagnostic challenges in this widely used classification scheme. METHODS: Four web-based digital pathology trials were completed by 20 neuropathologists from 15 countries using a consecutive series of 196 surgical tissue blocks obtained from 22 epilepsy patients at a single center. Five independent genetic laboratories performed screening or validation sequencing of FCD-relevant genes in paired brain and blood samples from the same 22 epilepsy patients. RESULTS: Histopathology agreement based solely on hematoxylin and eosin stainings was low in Round 1, and gradually increased by adding a panel of immunostainings in Round 2 and the Delphi consensus method in Round 3. Interobserver agreement was good in Round 4 (kappa = .65), when the results of genetic tests were disclosed, namely, MTOR, AKT3, and SLC35A2 brain somatic mutations in five cases and germline mutations in DEPDC5 and NPRL3 in two cases. SIGNIFICANCE: The diagnoses of FCD 1 and 3 subtypes remained most challenging and were often difficult to differentiate from a normal homotypic or heterotypic cortical architecture. Immunohistochemistry was helpful, however, to confirm the diagnosis of FCD or no lesion. We observed a genotype-phenotype association for brain somatic mutations in SLC35A2 in two cases with mild malformation of cortical development with oligodendroglial hyperplasia in epilepsy. Our results suggest that the current FCD classification should recognize a panel of immunohistochemical stainings for a better histopathological workup and definition of FCD subtypes. We also propose adding the level of genetic findings to obtain a comprehensive, reliable, and integrative genotype-phenotype diagnosis in the near future

    Reliability of MRI findings in candidates for lumbar disc prosthesis

    Get PDF
    Introduction: Limited reliability data exist for localised magnetic resonance imaging (MRI) findings relevant to planning of treatment with lumbar disc prosthesis and later outcomes. We assessed the reliability of such findings in chronic low back pain patients who were accepted candidates for disc prosthesis. Methods: On pretreatment MRI of 170 patients (mean age 41 years; 88 women), three experienced radiologists independently rated Modic changes, disc findings and facet arthropathy at L3/L4, L4/L5 and L5/S1. Two radiologists rerated 126 examinations. For each MRI finding at each disc level, agreement was analysed using the kappa statistic and differences in prevalence across observers using a fixed effects model. Results: All findings at L3/L4 and facet arthropathy at L5/S1 had a mean prevalence <10% across observers and were not further analysed, ensuring interpretable kappa values. Overall interobserver agreement was generally moderate or good (kappa 0.40–0.77) at L4–S1 for Modic changes, nucleus pulposus signal, disc height (subjective and measured), posterior high-intensity zone (HIZ) and disc contour, and fair (kappa 0.24) at L4/L5 for facet arthropathy. Posterior HIZ at L5/S1 and severely reduced subjective disc height at L4/L5 differed up to threefold in prevalence between observers (p< 0.0001). Intraobserver agreement was mostly good or very good (kappa 0.60–1.00). Conclusion: In candidates for disc prosthesis, mostly moderate interobserver agreement is expected for localised MRI findings

    A 10 year case study on the changing determinants of University student satisfaction in the UK

    Get PDF
    Higher Education (HE), once the prerogative of a tiny elite, is now accessible to larger numbers of people around the world than ever before yet despite the fact that an understanding of student satisfaction has never been more important for today’s universities, the concept remains poorly understood. Here we use published data from the UK’s National Student Survey (NSS), representing data from 2.3 million full-time students collected from 2007 to 2016, as a case study of the benefits and limitations of measuring student satisfaction that might have applicability for other countries, particularly those that, like the UK, have experienced significant growth in student numbers. The analyses showed that the factor structure of the NSS remained generally stable and that the ability of the NSS to discriminate between different subjects at different universities actually improved over the ten-year sample period. The best predictors of overall satisfaction were 'Teaching Quality' and 'Organisation & Management', with 'Assessment & Feedback' having relatively weak predictive ability, despite the sector's tangible efforts to improve on this metric. The tripling of student fees in 2012 for English students (but not the rest of the UK) was used as a ‘natural experiment’ to investigate the sensitivity of student satisfaction ratings to the real economic costs of HE. The tuition fee increase had no identifiable negative effect, with student satisfaction steadily improving throughout the decade. Although the NSS was never designed to measure perceived value-for money, its insensitivity to major changes in the economic costs of HE to the individual suggest that the conventional concept of student satisfaction is incomplete. As such we propose that the concept of student satisfaction: (i) needs to be widened to take into account the broader economic benefits to the individual student by including measures of perceived value-for-money and (ii) should measure students’ level of satisfaction in the years post-graduation, by which time they may have a greater appreciation of the value of their degree in the workplace

    A Cell-Based Small Molecule Screening Method for Identifying Inhibitors of Epithelial-Mesenchymal Transition in Carcinoma

    Get PDF
    Epithelial Mesenchymal Transition (EMT) is a crucial mechanism for carcinoma progression, as it provides routes for in situ carcinoma cells to dissociate and become motile, leading to localized invasion and metastatic spread. Targeting EMT therefore represents an important therapeutic strategy for cancer treatment. The discovery of oncogene addiction in sustaining tumor growth has led to the rapid development of targeted therapeutics. Whilst initially optimized as anti-proliferative agents, it is likely that some of these compounds may inhibit EMT initiation or sustenance, since EMT is also modulated by similar signaling pathways that these compounds were designed to target. We have developed a novel screening assay that can lead to the identification of compounds that can inhibit EMT initiated by growth factor signaling. This assay is designed as a high-content screening assay where both cell growth and cell migration can be analyzed simultaneously via time-course imaging in multi-well plates. Using this assay, we have validated several compounds as viable EMT inhibitors. In particular, we have identified compounds targeting ALK5, MEK, and SRC as potent inhibitors that can interfere with EGF, HGF, and IGF-1 induced EMT signaling. Overall, this EMT screening method provides a foundation for improving the therapeutic value of recently developed compounds in advanced stage carcinoma

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore