892 research outputs found

    Multipole Expansion of Bremsstrahlung in Intermediate Energy Heavy Ion Collisions

    Get PDF
    Using a multipole expansion of the radiated field generated by a classical electric current, we present a way to interprete the bremsstrahlung spectra of low energy heavy ion collisions. We perform the calculation explicitely for the system ^{12}C+ ^{12}C at 84AMeV and compare the result with the experimental data of E. Grosse et al. Using simple model assumptions for the electromagnetic source current we are able to describe the measured data in terms of coherent photon emission. In this context, the information contained in the measured data is discussed.Comment: LaTex, 4 Figure

    Number phase uncertainty relations: verification by homodyning

    Get PDF
    It is shown that fundamental uncertainty relations between photon number and canonical phase of a single-mode optical field can be verified by means of balanced homodyne measurement. All the relevant quantities can be sampled directly from the measured phase-dependent quadrature distribution.Comment: 1 Ps figure (divided in 3 subfigures) using REVTE

    Quantitative, Multi-institutional Evaluation of MR Thermometry Accuracy for Deep-Pelvic MR-Hyperthermia Systems Operating in Multi-vendor MR-systems Using a New Anthropomorphic Phantom

    Get PDF
    Clinical outcome of hyperthermia depends on the achieved target temperature, therefore target conformal heating is essential. Currently, invasive temperature probe measurements are the gold standard for temperature monitoring, however, they only provide limited sparse data. In contrast, magnetic resonance thermometry (MRT) provides unique capabilities to non-invasively measure the 3D-temperature. This study investigates MRT accuracy for MR-hyperthermia hybrid systems located at five European institutions while heating a centric or eccentric target in anthropomorphic phantoms with pelvic and spine structures. Scatter plots, root mean square error (RMSE) and Bland–Altman analysis were used to quantify accuracy of MRT compared to high resistance thermistor probe measurements. For all institutions, a linear relation between MRT and thermistor probes measurements was found with R 2 (mean ± standard deviation) of 0.97 ± 0.03 and 0.97 ± 0.02, respectively for centric and eccentric heating targets. The RMSE was found to be 0.52 ± 0.31 ◦C and 0.30 ± 0.20 ◦C, respectively. The Bland-Altman evaluation showed a mean difference of 0.46 ± 0.20 ◦C and 0.13 ± 0.08 ◦C, respectively. This first multi-institutional evaluation of MR-hyperthermia hybrid systems indicates comparable device performance and good agreement between MRT and thermistor probes measurements. This forms the basis to standardize treatments in multi-institution studies of MR-guided hyperthermia and to elucidate thermal dose-effect relations

    Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector

    Full text link
    Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the compact Osiris research reactor core (70MW) operating at the Saclay research centre of the French Alternative Energies and Atomic Energy Commission (CEA), the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the 0.85m3 detector remotely operating at a shallow depth equivalent to 12m of water and under intense background radiation conditions. Based on 145 (106) days of data with reactor ON (OFF), leading to the detection of an estimated 40760 electron antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +- 18(syst) electron antineutrinos/day, in agreement with the prediction 277(23) electron antineutrinos/day. Due the the large background no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement.Comment: 22 pages, 16 figures - Version

    Characterization of the interactions of a polycationic, amphiphilic, terminally branched oligopeptide with lipid A and lipopolysaccharide from the deep rough mutant of salmonella minnesota

    Get PDF
    The lipid A and lipopolysaccharide (LPS) binding and neutralizing activities of a synthetic, polycationic, amphiphilic peptide were studied. The branched peptide, designed as a functional analog of polymyxin B, has a six residue hydrophobic sequence, bearing at its N-terminus a penultimate lysine residue whose α- and E-amino groups are coupled to two terminal lysine residues. In fluorescence spectroscopic studies designed to examine relative affinities of binding to the toxin, neutralization of surface charge and fluidization of the acyl domains, the peptide was active, closely resembling the effects of polymyxin B and its nonapeptide derivative; however, the synthetic peptide does not induce phase transitions in LPS aggregates as do polymyxin B and polymyxin B nonapeptide. The peptide was also comparable with polymyxin B in its ability to inhibit LPS-mediated IL-1 and IL-6 release from human peripheral blood mononuclear cells. The synthetic compound is devoid of antibacterial activities and did not induce conductance fluxes in LPS-containing asymmetric planar membranes. These results strengthen the premise that basicity and amphiphilicity are necessary and sufficient physical properties that ascribe endotoxin binding and neutralizing activities, and further suggest that antibacterial/membrane perturbant and LPS neutralizing activities are dissociable, which may be of value in designing LPS-sequestering agents of low toxicity

    High intensity neutrino oscillation facilities in Europe

    Get PDF
    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ+ and μ− beams in a storage ring. The far detector in this case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular He6 and Ne18, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive

    A novel HSF4 gene mutation (p.R405X) causing autosomal recessive congenital cataracts in a large consanguineous family from Pakistan

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hereditary cataracts are most frequently inherited as autosomal dominant traits, but can also be inherited in an autosomal recessive or X-linked fashion. To date, 12 loci for autosomal recessive cataracts have been mapped including a locus on chromosome 16q22 containing the disease-causing gene <it>HSF4 </it>(Genbank accession number <ext-link ext-link-id="NM_001040667" ext-link-type="gen">NM_001040667</ext-link>). Here, we describe a family from Pakistan with the first nonsense mutation in <it>HSF4 </it>thus expanding the mutational spectrum of this heat shock transcription factor gene.</p> <p>Methods</p> <p>A large consanguineous Pakistani family with autosomal recessive cataracts was collected from Quetta. Genetic linkage analysis was performed for the common known autosomal recessive cataracts loci and linkage to a locus containing <it>HSF4 </it>(OMIM 602438) was found. All exons and adjacent splice sites of the heat shock transcription factor 4 gene (<it>HSF4</it>) were sequenced. A mutation-specific restriction enzyme digest (H<it>ph</it>I) was performed for all family members and unrelated controls.</p> <p>Results</p> <p>The disease phenotype perfectly co-segregated with markers flanking the known cataract gene HSF4, whereas other autosomal recessive loci were excluded. A maximum two-point LOD score with a Zmax = 5.6 at θ = 0 was obtained for D16S421. Direct sequencing of HSF4 revealed the nucleotide exchange c.1213C > T in this family predicting an arginine to stop codon exchange (p.R405X).</p> <p>Conclusion</p> <p>We identified the first nonsense mutation (p.R405X) in exon 11 of <it>HSF4 </it>in a large consanguineous Pakistani family with autosomal recessive cataract.</p

    A Top Quark Soliton and its Anomalous Chromomagnetic Moment

    Get PDF
    We show that under the assumption of dynamical symmetry breaking of electro weak interactions by a top quark condensate, motivated by the Top Mode Standard Model, the top quark in this effective theory can be considered then as chiral color soliton (qualiton). This is realized in an effective four-fermion interaction with chiral SU(3)cSU(3)_c as well as SU(2)LUY(1)SU(2)_L\otimes U_Y(1) symmetry. In the pure top sector the qualiton consists of a top valence quark and a Dirac sea of top and anti-top quark coupled to a color octet of Goldstone pions. The mass spectra, isoscalar quadratic radii and the anomalous chromomagnetic moment due to a non-trivial color form factor are calculated with zero and finite current top masses and effects at the Hadron Colliders are discussed. The anomalous chromomagnetic moment turns out to have a value consistent with the top production rates of the D0- and CDF-measurements.Comment: LaTeX, using RevTeX.sty and aps.sty, without figures, 16 pages, to be published in Physical Review D. Full postscript version and figures available on request or via ftp://hadron.tp2.ruhr-uni-bochum.de/preprint.tp2/1995/08-95.tar.g

    High prevalence of antibodies against polyomavirus WU, polyomavirus KI, and human bocavirus in German blood donors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>DNA of the polyomaviruses WU (WUPyV) and KI (KIPyV) and of human bocavirus (HBoV) has been detected with varying frequency in respiratory tract samples of children. However, only little is known about the humoral immune response against these viruses. Our aim was to establish virus-specific serological assays and to determine the prevalence of immunoglobulin G (IgG) against these three viruses in the general population.</p> <p>Methods</p> <p>The capsid proteins VP1 of WUPyV and KIPyV and VP2 of HBoV were cloned into baculovirus vectors and expressed in Sf9 insect cells. IgG antibodies against WUPyV VP1, KIPyV VP1, and HBoV VP2 were determined by immunofluorescence assays in 100 plasma samples of blood donors.</p> <p>Results</p> <p>The median age of the blood donors was 31 years (range 20 - 66 yrs), 52% were male. 89% of the samples were positive for WUPyV IgG (median age 31 yrs, 49.4% male), 67% were positive for KIPyV IgG (median age 32 yrs, 46.3% male), and 76% were positive for HBoV IgG (median age 32 yrs, 51.3% male). For WUPyV and HBoV, there were no significant differences of the seropositivity rates with respect to age groups or gender. For KIPyV, the seropositivity rate increased significantly from 59% in the age group 20 - 29 years to 100% in the age group > 50 years.</p> <p>Conclusions</p> <p>High prevalences of antibodies against WUPyV, KIPyV, and HBoV were found in plasma samples of healthy adults. The results indicate that primary infection with these viruses occurs during childhood or youth. For KIPyV, the seropositivity appears to increase further during adulthood.</p
    corecore