75 research outputs found

    ROOOH: A missing piece of the puzzle for OH measurements in low-NO environments?

    Get PDF
    Abstract. Field campaigns have been carried out with the FAGE (fluorescence assay by gas expansion) technique in remote biogenic environments in the last decade to quantify the in situ concentrations of OH, the main oxidant in the atmosphere. These data have revealed concentrations of OH radicals up to a factor of 10 higher than predicted by models, whereby the disagreement increases with decreasing NO concentration. This was interpreted as a major lack in our understanding of the chemistry of biogenic VOCs (volatile organic compounds), particularly isoprene, which are dominant in remote pristine conditions. But interferences in these measurements of unknown origin have also been discovered for some FAGE instruments: using a pre-injector, all ambient OH is removed by fast reaction before entering the FAGE cell, and any remaining OH signal can be attributed to an interference. This technique is now systematically used for FAGE measurements, allowing the reliable quantification of ambient OH concentrations along with the signal due to interference OH. However, the disagreement between modelled and measured high OH concentrations of earlier field campaigns as well as the origin of the now-quantifiable background OH is still not understood. We present in this paper the compelling idea that this interference, and thus the disagreement between model and measurement in earlier field campaigns, might be at least partially due to the unexpected decomposition of a new class of molecule, ROOOH, within the FAGE instruments. This idea is based on experiments, obtained with the FAGE set-up of the University of Lille, and supported by a modelling study. Even though the occurrence of this interference will be highly dependent on the design and measurement conditions of different FAGE instruments, including ROOOH in atmospheric chemistry models might reflect a missing piece of the puzzle in our understanding of OH in clean atmospheres. </jats:p

    Ultrastructural morphology and cytochemistry of iron-deficient polymorphonuclear leukocytes

    Full text link
    Previous studies have documented decreased activities of certain enzymes and altered function in polymorphonuclear leukocytes (PMN) during iron deficiency. The present study was undertaken to determine if the enzymatic abnormalities could be correlated with morphologic or quantitative change in PMN granules. Ultrastructural examination of primary and secondary granules and assessment of the secondary granule components alkaline phosphatase and vicinal glycol-containing glycoconjugates was performed in rabbit bone marrow, peripheral blood, and peritoneal heterophils. In addition, biochemical quantifications of the secondary granule component alkaline phosphatase and the primary granule marker [beta]-glucuronidase were performed. The results confirmed that a marked, significant decrease in alkaline phosphatase occurs in iron-deficient animals; however, no biochemical decrease in [beta]-glucuronidase activity was observed. Ultrastructurally, PMN secondary granules of iron-deficient rabbits tended to be more numerous than in controls when examined with morphometric and glycoconjugate staining methods, but lacked staining in alkaline phosphatase preparations. These results demonstrate that iron-deficient rabbits produce normal to increased quantities of primary and secondary granules, despite a uniform deficiency of alkaline phosphatase, a secondary granule marker.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/26267/1/0000352.pd

    Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Get PDF
    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios up to 100 ppbv. The CRM technique has hitherto mainly been used in low-NOx environments, i.e. environments with ambient NOx mixing ratios lower than a few ppbv, due to a measurement artifact generated by ambient NO inside the sampling reactor. However, this study shows that this technique can also be used under NOx-rich conditions if a NOx-dependent correction is carefully applied on the OH reactivity measurements. A full suite of 52 VOCs, NOx, and other inorganic species were monitored during this intercomparison. An investigation of the OH reactivity budget for this urban site suggests that this suite of trace gases can account for the measured total OH reactivity

    The sensitizing effects of NO2and NO on methane low temperature oxidation in a jet stirred reactor

    Get PDF
    The oxidation of neat methane (CH4) and CH4doped with NO2or NO in argon has been investigated in a jet-stirred reactor at 107 kPa, temperatures between 650 and 1200 K, with a fixed residence time of 1.5 s, and for different equivalence ratios (Φ), ranging from fuel-lean to fuel-rich conditions. Four different diagnostics have been used: gas chromatography (GC), chemiluminescence NOxanalyzer, continuous wave cavity ring-down spectroscopy (cw-CRDS) and Fourier transform infrared spectroscopy (FTIR). In the case of the oxidation of neat methane, the onset temperature for CH4oxidation was above 1025 K, while it is shifted to 825 K with the addition of NO2or NO, independently of equivalence ratio, indicating that the addition of NO2or NO highly promotes CH4oxidation. The consumption rate of CH4exhibits a similar trend with the presence of both NO2and NO. The amount of produced HCN has been quantified and a search for HONO and CH3NO2species has been attempted. A detailed kinetic mechanism, derived from POLIMI kinetic framework, has been used to interpret the experimental data with a good agreement between experimental data and model predictions. Reaction rate and sensitivity analysis have been conducted to illustrate the kinetic regimes. The fact that the addition of NO or NO2seems to have similar effects on promoting CH4oxidation can be explained by the fact that both species are involved in a reaction cycle interchanging them and whose result is 2CH3+ O2= 2CH2O + 2H. Additionally, the direct participation of NO2in the NO2+ CH2O = HONO + HCO reaction has a notable accelerating effect on methane oxidation

    On the status and mechanisms of coastal erosion in Marawila Beach, Sri Lanka

    Get PDF
    Coastal erosion remains a problem in many developing countries because of a limited understating of erosion mechanisms and management. Sri Lanka is one of the countries that recognized coastal erosion management as a governmental responsibility, in 1984. Nevertheless, erosion mechanisms have not yet been fully understood. We investigate the status and mechanisms of coastal erosion using empirically collected data and various techniques, such as Geographic Information System analysis of satellite images, drone mapping, bathymetric surveys, hindcasting of wind-induced wave climate, questionnaires, and semi-structured interview surveys. We identified wave climate change, reduction in river sand supply, interruptions from previous erosion management measures, and offshore sand mining as potential causes of erosion considering sediment flux and rates of erosion. Erosion of Marawila Beach began during 2005–2010 and has been continuing ever since, due to a lack of integration in the beach and the entire sediment system. It is necessary to identify the long-term, large-scale changes in the sediment system through data collection. This study highlights the importance of an integrated coastal erosion management plan and could facilitate better coastal erosion management in Sri Lanka, as well as in other developing countries

    Impact of system factors on the water saving efficiency of household grey water recycling

    Get PDF
    Copyright © 2010 Taylor & Francis. This is an Author's Accepted Manuscript of an article published in Desalination and Water Treatment Volume 24, Issue 1-3 (2010), available online at: http://www.tandfonline.com/10.5004/dwt.2010.1542A general concern when considering the implementation of domestic grey water recycling is to understand the impacts of system factors on water saving efficiency. Key factors include household occupancy, storage volumes, treatment capacity and operating mode. Earlier investigations of the impacts of these key factors were based on a one-tank system only. This paper presents the results of an investigation into the effect of these factors on the performance of a more realistic ‘two tank’ system with treatment using an object based household water cycle model. A Monte-Carlo simulation technique was adopted to generate domestic water appliance usage data which allows long-term prediction of the system's performance to be made. Model results reveal the constraints of treatment capacity, storage tank sizes and operating mode on percentage of potable water saved. A treatment capacity threshold has been discovered at which water saving efficiency is maximised for a given pair of grey and treated grey water tank. Results from the analysis suggest that the previous one-tank model significantly underestimates the tank volumes required for a given target water saving efficiency

    Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser

    Get PDF
    We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (uc) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 μg (1490 droplets) with uc = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies

    Comparison of OH reactivity measurements in the atmospheric simulation chamber SAPHIR

    Get PDF
    Hydroxyl (OH) radical reactivity (kOH) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements (limit of detection  < 1 s−1 at a time resolution of 30 s to a few minutes) is higher for instruments directly detecting hydroxyl radicals, whereas the indirect comparative reactivity method (CRM) has a higher limit of detection of 2 s−1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapour or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds (mixing ratio of OH reactants were up to 10 ppbv). In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied to account for known effects of, for example, deviations from pseudo first-order conditions, nitrogen oxides or water vapour on the measurement. Methods used to derive these corrections vary among the different CRM instruments. Measurements taken with a flow-tube instrument combined with the direct detection of OH by chemical ionisation mass spectrometry (CIMS) show limitations in cases of high reactivity and high NO concentrations but were accurate for low reactivity (< 15 s−1) and low NO (< 5 ppbv) conditions

    The 2015 edition of the GEISA spectroscopic database

    Get PDF
    The GEISA database (Gestion et Etude des Informations Spectroscopiques Atmosphériques: Management and Study of Atmospheric Spectroscopic Information) has been developed and maintained by the ARA/ABC(t) group at LMD since 1974. GEISA is constantly evolving, taking into account the best available spectroscopic data. This paper presents the 2015 release of GEISA (GEISA-2015), which updates the last edition of 2011 and celebrates the 40th anniversary of the database. Significant updates and additions have been implemented in the three following independent databases of GEISA. The “line parameters database” contains 52 molecular species (118 isotopologues) and transitions in the spectral range from 10−6 to 35,877.031 cm−1, representing 5,067,351 entries, against 3,794,297 in GEISA-2011. Among the previously existing molecules, 20 molecular species have been updated. A new molecule (SO3) has been added. HDO, isotopologue of H2O, is now identified as an independent molecular species. Seven new isotopologues have been added to the GEISA-2015 database. The “cross section sub-database” has been enriched by the addition of 43 new molecular species in its infrared part, 4 molecules (ethane, propane, acetone, acetonitrile) are also updated; they represent 3% of the update. A new section is added, in the near-infrared spectral region, involving 7 molecular species: CH3CN, CH3I, CH3O2, H2CO, HO2, HONO, NH3. The “microphysical and optical properties of atmospheric aerosols sub-database” has been updated for the first time since 2003. It contains more than 40 species originating from NCAR and 20 from the ARIA archive of Oxford University. As for the previous versions, this new release of GEISA and associated management software facilities are implemented and freely accessible on the AERIS/ESPRI atmospheric chemistry data center website
    corecore