170 research outputs found

    Acceptability and feasibility of magnetic femoral nerve stimulation in older, functionally impaired patients

    Get PDF
    Abstract Objective Magnetic femoral nerve stimulation to test muscle function has been largely unexplored in older people. We assessed acceptability, feasibility, along with reproducibility and correlation with other physical function measures. Results Study 1 recruited older people with sarcopenia. Stimulation was performed at baseline and 2 weeks along with six minute walk (6MW), maximum voluntary quadriceps contraction, short physical performance battery and grip strength. Acceptability was measured using visual analog scales. Study 2 used baseline data from a trial of older people. We correlated stimulation results with 6MW, maximal voluntary contraction and muscle mass. Maximum quadriceps twitch tension was measured in both studies, evoked using biphasic magnetic stimulation of the femoral nerve. In study 1 (n = 12), magnetic stimulation was well tolerated with mean discomfort rating of 9% (range 0–40%) on a visual analog scale. Reproducibility was poor (intraclass correlation coefficient 0.06; p = 0.44). Study 2 (n = 64) showed only weak to moderate correlations for maximum quadriceps twitch tension with other measures of physical function (6 minute walk test r = 0.24, p = 0.06; maximal voluntary contraction r = 0.26; p = 0.04). We conclude that magnetic femoral nerve stimulation is acceptable and feasible but poorly reproducible in older, functionally impaired people

    A Combined Pulmonary Function and Emphysema Score Prognostic Index for Staging in Chronic Obstructive Pulmonary Disease

    No full text
    Chronic Obstructive Pulmonary Disease (COPD) is characterized by high morbidity and mortality. Lung computed tomography parameters, individually or as part of a composite index, may provide more prognostic information than pulmonary function tests alone.To investigate the prognostic value of emphysema score and pulmonary artery measurements compared with lung function parameters in COPD and construct a prognostic index using a contingent staging approach.Predictors of mortality were assessed in COPD outpatients whose lung computed tomography, spirometry, lung volumes and gas transfer data were collected prospectively in a clinical database. Univariate and multivariate Cox proportional hazard analysis models with bootstrap techniques were used.169 patients were included (59.8% male, 61.1 years old; Forced Expiratory Volume in 1 second % predicted: 40.5±19.2). 20.1% died; mean survival was 115.4 months. Age (HR = 1.098, 95% Cl = 1.04-1.252) and emphysema score (HR = 1.034, 95% CI = 1.007-1.07) were the only independent predictors of mortality. Pulmonary artery dimensions were not associated with survival. An emphysema score of 55% was chosen as the optimal threshold and 30% and 65% as suboptimals. Where emphysema score was between 30% and 65% (intermediate risk) the optimal lung volume threshold, a functional residual capacity of 210% predicted, was applied. This contingent staging approach separated patients with an intermediate risk based on emphysema score alone into high risk (Functional Residual Capacity ≥210% predicted) or low risk (Functional Residual Capacity <210% predicted). This approach was more discriminatory for survival (HR = 3.123; 95% CI = 1.094-10.412) than either individual component alone.Although to an extent limited by the small sample size, this preliminary study indicates that the composite Emphysema score-Functional Residual Capacity index might provide a better separation of high and low risk patients with COPD, than other individual predictors alone

    Repeatability and validity of a standardised maximal step-up test for leg function-a diagnostic accuracy study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Objectively assessed physical performance is a strong predictor for morbidity and premature death and there is an increasing interest in the role of sarcopenia in many chronic diseases. There is a need for robust and valid functional tests in clinical practice. Therefore, the repeatability and validity of a newly developed maximal step up test (MST) was assessed.</p> <p>Methods</p> <p>The MST, assessing maximal step-up height (MSH) in 3-cm increments, was evaluated in 60 healthy middle-aged subjects, 30 women and 30 men. The repeatability of MSH and the correlation between MSH and isokinetic knee extension peak torque (IKEPT), self-reported physical function (SF-36, PF), patient demographics and self-reported physical activity were investigated.</p> <p>Results</p> <p>The repeatability between occasions and between testers was 6 cm. MSH (range 12-45 cm) was significantly correlated to IKEPT, (<it>r </it>= 0.68, <it>P </it>< 0.001), SF-36 PF score, (<it>r </it>= 0.29, <it>P </it>= 0.03), sex, age, weight and BMI. The results also show that MSH above 32 cm discriminates subjects in our study with no limitation in self-reported physical function.</p> <p>Conclusions</p> <p>The standardised MST is considered a reliable leg function test for clinical practice. The MSH was related to knee extension strength and self-reported physical function. The precision of the MST for identification of limitations in physical function needs further investigation.</p

    A prospective study of decline in fat free mass and skeletal muscle strength in chronic obstructive pulmonary disease

    Get PDF
    BACKGROUND: Skeletal muscle depletion is an important complication of chronic obstructive pulmonary disease (COPD) but little prospective data exists about the rate at which it occurs and the factors that promote its development. We therefore prospectively investigated the impact of disease severity, exacerbation frequency and treatment with corticosteroids on change in body composition and maximum isometric quadriceps strength (QMVC) over one year. METHODS: 64 patients with stable COPD (FEV(1 )mean (SD) 35.8(18.4) %predicted) were recruited from clinic and studied on two occasions one year apart. Fat free mass was determined using bioelectrical impedance analysis and a disease specific regression equation. RESULTS: QMVC fell from 34.8(1.5) kg to 33.3(1.5) kg (p = 0.04). The decline in quadriceps strength was greatest in those with the highest strength at baseline (R -0.28 p = 0.02) and was not correlated with lung function, exacerbation frequency or steroid treatment. Decline in fat free mass was similarly higher in those with largest FFM at baseline (R = -0.31 p = 0.01) but was more strongly correlated with greater gas trapping (R = -0.4 p = 0.001). Patients with frequent exacerbations (>1 per year) (n = 36) experienced a greater decline in fat free mass compared to infrequent exacerbators (n = 28) -1.3(3.7)kg vs. +1.2(3.1)kg (p = 0.005), as did patients on maintenance oral steroids (n = 8) -2.8(3.3) kg vs. +0.2(3.5) kg (p = 0.024) whereas in those who stopped smoking (n = 7) fat free mass increased; +2.7(3.1) kg vs. -0.51(3.5) kg (p = 0.026). CONCLUSION: Decline in fat free mass in COPD is associated with worse lung function, continued cigarette consumption and frequent exacerbations. Factors predicting progression of quadriceps weakness could not be identified from the present cohort

    Non-invasive ventilation (NIV) as an aid to rehabilitation in acute respiratory disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Non-invasive ventilation (NIV) can increase exercise tolerance, reduce exercise induced desaturation and improve the outcome of pulmonary rehabilitation in patients with chronic respiratory disease. It is not known whether it can be applied to increase exercise capacity in patients admitted with non-hypercapnic acute exacerbations of COPD (AECOPD). We investigated the acceptability and feasibility of using NIV for this purpose.</p> <p>Methods</p> <p>On a single occasion, patients admitted with an acute exacerbation of chronic respiratory disease who were unable to cycle for five minutes at 20 watts attempted to cycle using NIV and their endurance time (T<sub>lim</sub>) was recorded. To determine feasibility of this approach in clinical practice patients admitted with AECOPD were screened for participation in a trial of regular NIV assisted rehabilitation during their hospital admission.</p> <p>Results</p> <p>In 12 patients tested on a single occasion NIV increased T<sub>lim </sub>from 184(65) seconds to 331(229) seconds (p = 0.04) and patients desaturated less (median difference = 3.5%, p = 0.029). In the second study, 60 patients were admitted to hospital during a three month period of whom only 18(30)% were eligible to participate and of these patients, only four (7%) consented to participate.</p> <p>Conclusion</p> <p>NIV improves exercise tolerance in patients with acute exacerbations of chronic respiratory disease but the applicability of this approach in routine clinical practice may be limited.</p> <p>Trial registration</p> <p><url>http://www.controlled-trials.com/ISRCTN35692743</url></p

    Health enhancing strength training in nonagenarians (STRONG): rationale, design and methods

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Health Enhancing Strength Training in Nonagenarians (STRONG) is a randomised control trial to assess the effectiveness of an aerobic and strength training program for improving muscle strength, functional capacity and quality of life in nonagenarians.</p> <p>Methods</p> <p>Sixty (51 women) nonagenarians (age range: 90–102 years) who live in a geriatric nursing home will be randomly assigned to either a usual care (control) group (n = 30) or an intervention (training) group (n = 30). Participants allocated in the usual care group will receive general physical activity guidelines and participants allocated in the intervention group will also enrol in three weekly non-consecutive individualized training sessions (~45–50 min each) during 8 weeks. The exercise program will consist of muscular strength [with a special focus on leg press at 30% (start of the program) to 70% 1 repetition maximum (end)] and aerobic exercises (cycle-ergometry during 3–5 to 15 minutes at 12–14 points in the rate of perceived exertion scale).</p> <p>Results</p> <p>Results from STRONG will help to better understand the potential of regular physical activity for improving the well-being of the oldest population groups.</p> <p>Conclusion</p> <p>The increase in life expectancy together with the dramatic decrease in birth rates in industrialized countries calls the attention to health care systems and public health policymakers to focus attention on promoting healthy lifestyle in the highest sector of the population pyramid. Our study attempts to improve functional capacity and QOL of nonagenarians by implementing an individualised aerobic and strength training program in a geriatric residential care. Results from STRONG will help to better understand the potential of regular physical activity for improving the well being even in persons aged 90 years or over.</p> <p>Trail Registration</p> <p>ClinicalTrials.gov ID: NCT00848978</p

    Search for production of an invisible dark photon in π0 decays

    Get PDF
    The results of a search for π0 decays to a photon and an invisible massive dark photon at the NA62 experiment at the CERN SPS are reported. From a total of 4.12 x 10^8 tagged π0 mesons, no signal is observed. Assuming a kinetic-mixing interaction, limits are set on the dark photon coupling to the ordinary photon as a function of the dark photon mass, improving on previous searches in the mass range 60-110 MeV/c^2. The present results are interpreted in terms of an upper limit of the branching ratio of the electro-weak decay π0→γνν¯, improving the current limit by more than three orders of magnitude

    An investigation of the very rare K+ → π+ vv¯ decay

    Get PDF
    The NA62 experiment reports an investigation of the K+→π+ν ̄ν mode from a sample of K+ decays collected in 2017 at the CERN SPS. The experiment has achieved a single event sensitivity of (0.389±0.024)×10−10, corresponding to 2.2 events assuming the Standard Model branching ratio of (8.4±1.0)×10−11. Two signal candidates are observed with an expected background of 1.5 events. Combined with the result of a similar analysis conducted by NA62 on a smaller data set recorded in 2016, the collaboration now reports an upper limit of 1.78×10−10 for the K+→π+ν ̄ν branching ratio at 90% CL. This, together with the corresponding 68% CL measurement of (0.48+0.72−0.48)×10−10, are currently the most precise results worldwide, and are able to constrain some New Physics models that predict large enhancements still allowed by previous measurements
    corecore