Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
Results of observations of low energy nuclear and electron recoil events in
liquid xenon scintillator detectors are given. The relative scintillation
efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40
keV - 70 keV. Under the assumption of a single dominant decay component to the
scintillation pulse-shape the log-normal mean parameter T0 of the maximum
likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV
nuclear recoil events is equal to 21.0 ns +/- 0.5 ns. It is observed that for
electron recoils T0 rises slowly with energy, having a value ~ 30 ns at Eee ~
15 keV. Electron and nuclear recoil pulse-shapes are found to be well fitted by
single exponential functions although some evidence is found for a double
exponential form for the nuclear recoil pulse-shape.Comment: 11 pages, including 5 encapsulated postscript figure
A Study of the Scintillation Induced by Alpha Particles and Gamma Rays in Liquid Xenon in an Electric Field
Scintillation produced in liquid xenon by alpha particles and gamma rays has
been studied as a function of applied electric field. For back scattered gamma
rays with energy of about 200 keV, the number of scintillation photons was
found to decrease by 64+/-2% with increasing field strength. Consequently, the
pulse shape discrimination power between alpha particles and gamma rays is
found to reduce with increasing field, but remaining non-zero at higher fields.Comment: 15 pages, 12 figures, accepted by Nuclear Instruments and Methods in
Physics Research
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
Ethnocentrism in the Low Countries: A comparative perspective
Contains fulltext :
3361.pdf (publisher's version ) (Open Access)New Community, continued by: Journal of ethnic and migration studies [1369-183X
Detector Description and Performance for the First Coincidence Observations between LIGO and GEO
For 17 days in August and September 2002, the LIGO and GEO interferometer
gravitational wave detectors were operated in coincidence to produce their
first data for scientific analysis. Although the detectors were still far from
their design sensitivity levels, the data can be used to place better upper
limits on the flux of gravitational waves incident on the earth than previous
direct measurements. This paper describes the instruments and the data in some
detail, as a companion to analysis papers based on the first data.Comment: 41 pages, 9 figures 17 Sept 03: author list amended, minor editorial
change
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
pb to the WIMP-nucleon cross-section.Comment: Submitted to Astroparticle Physic
Normas preliminares DRIS desarrolladas para caña de azĂșcar a partir de un bajo nĂșmero de muestras