49 research outputs found

    Tracing the Nature of Dark Energy with Galaxy Distribution

    Full text link
    Dynamical Dark Energy (DE) is a viable alternative to the cosmological constant. Yet, constructing tests to discriminate between Lambda and dynamical DE models is difficult because the differences are not large. In this paper we explore tests based on the galaxy mass function, the void probability function (VPF), and the number of galaxy clusters. At high z the number density of clusters shows large differences between DE models, but geometrical factors reduce the differences substantially. We find that detecting a model dependence in the cluster redshift distribution is a hard challenge. We show that the galaxy redshift distribution is potentially a more sensitive characteristics. We do so by populating dark matter halos in Nbody simulations with galaxies using well-tested Halo Occupation Distribution (HOD). We also estimate the Void Probability Function and find that, in samples with the same angular surface density of galaxies in different models, the VPF is almost model independent and cannot be used as a test for DE. Once again, geometry and cosmic evolution compensate each other. By comparing VPF's for samples with fixed galaxy mass limits, we find measurable differences.Comment: 12 pages, 11 figures, dependence on mass-luminosity relation discussed, minor changes to match the accepted version by MNRA

    Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring

    Get PDF
    Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scannerbeam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options. based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadro

    Tracing the nature of dark energy with galaxy distribution

    Get PDF
    Dynamical dark energy (DE) is a viable alternative to the cosmological constant. Constructing tests to discriminate between Λ and dynamical DE models is difficult, however, because the differences are not large. In this paper we explore tests based on the galaxy mass function, the void probability function (VPF), and the number of galaxy clusters. At high z, the number density of clusters shows large differences between DE models, but geometrical factors reduce the differences substantially. We find that detecting a model dependence in the cluster redshift distribution is a significant challenge. We show that the galaxy redshift distribution is potentially a more sensitive characteristic. We do this by populating dark matter haloes in N-body simulations with galaxies using well-tested halo occupation distributions. We also estimate the VPF and find that samples with the same angular surface density of galaxies, in different models, exhibition almost model-independent VPF which therefore cannot be used as a test for DE. Once again, geometry and cosmic evolution compensate each other. By comparing VPFs for samples with fixed galaxy mass limits, we find measurable difference

    Spectroscopic properties and radiation damage investigation of a diamond based Schottky diode for ion-beam therapy microdosimetry

    Get PDF
    In this work, a detailed analysis of the properties of a novel microdosimeter based on a synthetic single crystal diamond is reported. Focused ion microbeams were used to investigate the device spectropscopic properties as well as the induced radiation damageeffects. A diamond based Schottky diode was fabricated by chemical vapor deposition with a very thin detecting region, about 400 nm thick (approximately 1.4 Όm water equivalent thickness), corresponding to the typical size in microdosimetric measurements. A 200 × 200 Όm2 square metallic contact was patterned on the diamond surface by standard photolithography to define the sensitive area. Experimental measurements were carried out at the Ruder BoĆĄkovicâ€Č Institute microbeam facility using 4 MeV carbon and 5 MeV silicon ions. Ion beam induced charge maps were employed to characterize the microdosimeter response in terms of its charge collection properties. A stable response with no evidence of polarization or memory effects was observed up to the maximum investigated ion beam flux of about 1.7 × 109 ions·cm−2·s−1. A homogeneity of the response about 6% was found over the sensitive region with a well-defined confinement of the response within the active area. Tests of the radiation damageeffect were performed by selectively irradiating small areas of the device with different ion fluences, up to about 1012 ions/cm2. An exponential decrease of the charge collection efficiency was observed with a characteristic decay constant of about 4.8 MGy and 1 MGy for C and Si ions, respectively. The experimental data were analyzed by means of GEANT4 Monte Carlo simulations. A direct correlation between the diamond damaging effect and the Non Ionizing Energy Loss (NIEL) fraction was found. In particular, an exponential decay of the charge collection efficiency with an exponential decay as a function of NIEL is observed, with a characteristic constant of about 9.3 kGy-NIEL for both carbon and silicon ions

    Dynamical quintessence fields Press-Schechter mass function: detectability and effect on dark haloes

    Full text link
    We present an investigations on the influence of dynamical quintessence field models on the formation of non-linear structures. In particular, we focus on the structure traced by the mass function. Our contribution builds on previous studies by considering two potentials not treated previousy and investigating the impact of the free parameters of two other models. Our approach emphasises the physical insight into the key role of the evolution of the equation of state. We use the variations in the spherical non-linear collapse caused by quintessence as a function of the model's potential in a Press Schechter scheme to obtain the differences in halo mass functions. The comparison is also done with the more usual scenario Λ\LambdaCDM. We conclude the method should be promissing for discrimination using cluster mass determination and that the key role lies within the evolution of the equation of state.Comment: submitted to JCAP, 22pp, corrected typo in eq.(3.3

    Decoupling Dark Energy from Matter

    Get PDF
    We examine the embedding of dark energy in high energy models based upon supergravity and extend the usual phenomenological setting comprising an observable sector and a hidden supersymmetry breaking sector by including a third sector leading to the acceleration of the expansion of the universe. We find that gravitational constraints on the non-existence of a fifth force naturally imply that the dark energy sector must possess an approximate shift symmetry. When exact, the shift symmetry provides an example of a dark energy sector with a runaway potential and a nearly massless dark energy field whose coupling to matter is very weak, contrary to the usual lore that dark energy fields must couple strongly to matter and lead to gravitational inconsistencies. Moreover, the shape of the potential is stable under one-loop radiative corrections. When the shift symmetry is slightly broken by higher order terms in the KĂ€hler potential, the coupling to matter remains small. However, the cosmological dynamics are largely affected by the shift symmetry breaking operators leading to the appearance of a minimum of the scalar potential such that dark energy behaves like an effective cosmological constant from very early on in the history of the universe

    AX-PET: A novel PET concept with G-APD readout

    Get PDF
    Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-like 22 Na sources. Their performance in terms of energy ( R energy ≈ 11.8 % (FWMH) at 511 keV) and spatial resolution was assessed ( σ axial ≈ 0.65 mm ), both individually and for the two modules in coincidence. Test campaigns at ETH Zurich and at the company AAA allowed the tomographic reconstructions of more complex phantoms validating the 3D reconstruction algorithms. The concept of the AX-PET modules will be presented together with some characterization results. We describe a count rate model which allows to optimize the planing of the tomographic scans

    First results from the AX-PET demonstrator

    Get PDF
    The AX-PET demonstrator is based on a new concept in PET detectors, with LYSO crystals aligned along the z coordinate (patient's axis) and WLS (Wave-length shifter) strips placed orthogonal to them. This kind of structure permits to avoid parallax errors due to different depths of interaction of the photons in the crystals, to register the three coordinates of the impinging photon and to reconstruct Compton events. In this way both the spatial resolution and the sensitivity can be highly improved. Moreover, as both the LYSO crystals and the strips are readout via Geiger-mode Avalanche Photo Diodes (G-APDs) the detector is insensitive to magnetic fields and is then suitable to be used in a combined PET/MRI apparatus. A complete Monte Carlo simulation and dedicated reconstruction software, suited to the particular geometry arrangement, have been developed. The two final modules, each composed by 48 crystals and 156 WLS strips have been built and fully characterized in a dedicated test set-up. The results on the performances of the system obtained with a 22Na point source (0.25 mm diameter) are reported

    Imprints of Dark Energy on Cosmic Structure Formation I) Realistic Quintessence Models and the Non-Linear Matter Power Spectrum

    Full text link
    Dark energy as a quintessence component causes a typical modification of the background cosmic expansion, which in addition to its clustering properties, can leave a potentially distinctive signature on large scale structures. Many previous studies have investigated this topic, particularly in relation to the non-linear regime of structure formation. However, no careful pre-selection of viable quintessence models with high precision cosmological data was performed. Here we show that this has led to a misinterpretation (and underestimation) of the imprint of quintessence on the distribution of large scale structures. To this purpose we perform a likelihood analysis of the combined Supernova Ia UNION dataset and WMAP5-years data to identify realistic quintessence models. Differences from the vanilla LambdaCDM are especially manifest in the predicted amplitude and shape of the linear matter power spectrum, though these remain within the uncertainties of the SDSS data. We use these models as benchmark for studying the clustering properties of dark matter halos by performing a series of high resolution N-body simulations. We find that realistic quintessence models allow for relevant differences of the dark matter distribution with the respect to the LambdaCDM scenario well into the non-linear regime, with deviations up to 40% in the non-linear power spectrum. Such differences are shown to depend on the nature of DE, as well as the scale and epoch considered. At small scales (k~1-5 h Mpc^{-1}, depending on the redshift) the structure formation process is about 20% more efficient than in LambdaCDM. We show that these imprints are a specific record of the cosmic structure formation history in DE cosmologies and therefore cannot be accounted in standard fitting functions of the non-linear matter power spectrum.Comment: 24 pages, 11 figures. Higher resolution paper available at http://cp3.phys.ucl.ac.be/upload/papers/astro-ph-0903.5490.ps (ps) and http://cp3.phys.ucl.ac.be/upload/papers/astro-ph-0903.5490.pdf (pdf). v2: New discussion on the non-linear power spectrum at small scales. v3: same as v2 with corrected references. Matches version to appear in MNRA
    corecore