1,435 research outputs found
Condensation Risk – Impact of Improvements to Part L and Robust Details on Part C -Interim report number 7: Final report on project fieldwork
This report sets out, in draft1, the results of the fieldwork phase of research into the impacts of the 2002 revisions to Part L of the building regulations (Approved Document L1 - DTLR, 2001), and the adoption of Robust Details (RDs - DEFRA 2001) on the extent of condensation risk in the construction of dwellings (Oreszczyn and Bell, 2003). The objective of the fieldwork was to explore the practical application of the revised Part L and its associated robust details by housing developers. This was done through a qualitative evaluation of the design and construction of 16 housing schemes designed in accordance with the revised part L and making use of robust details2. The results of the analysis are to be used to enable condensation modelling that takes into account not only the guidance of robust details but also the way in which construction details were actually designed and, perhaps more importantly, constructed. To this end the report identifies 7 areas of construction detailing (yielding some 15 separate detail models) that are to be included in the condensation modelling phase of the project
Airtightness of buildings — towards higher performance: Final Report — Domestic Sector Airtightness
This report constitutes milestone D11 — Final Report — Domestic Sector Airtightness of the Communities and Local Government/ODPM Project reference CI 61/6/16 (BD2429) Airtightness of Buildings — Towards Higher Performance (Borland and Bell, 2003). This report presents the overall conclusions and key messages obtained from the project through design assessments, construction observations, discussions with developers and pressurisation test results. It also summarises discussion on the airtight performance of current UK housing, the implementation and impact of current and future legislation, and identifies potential areas for future work
Low carbon housing: lessons from Elm Tree Mews
This report sets out the findings from a low carbon housing trial at Elm Tree Mews, York, and discusses the technical and policy issues that arise from it. The Government has set an ambitious target for all new housing to be zero carbon by 2016. With the application of good insulation, improved efficiencies and renewable energy, this is theoretically possible. However, there is growing concern that, in practice, even existing carbon standards are not being achieved and that this performance gap has the potential to undermine zero carbon housing policy. The report seeks to address these concerns through the detailed evaluation of a low carbon development at Elm Tree Mews. The report: * evaluates the energy/carbon performance of the dwellings prior to occupation and in use; * analyses the procurement, design and construction processes that give rise to the performance achieved; * explores the resident experience; * draws out lessons for the development of zero carbon housing and the implications for government policy; and * proposes a programme for change, designed to close the performance gap
Application of asymptotic expansions of maximum likelihood estimators errors to gravitational waves from binary mergers: the single interferometer case
In this paper we describe a new methodology to calculate analytically the
error for a maximum likelihood estimate (MLE) for physical parameters from
Gravitational wave signals. All the existing litterature focuses on the usage
of the Cramer Rao Lower bounds (CRLB) as a mean to approximate the errors for
large signal to noise ratios. We show here how the variance and the bias of a
MLE estimate can be expressed instead in inverse powers of the signal to noise
ratios where the first order in the variance expansion is the CRLB. As an
application we compute the second order of the variance and bias for MLE of
physical parameters from the inspiral phase of binary mergers and for noises of
gravitational wave interferometers . We also compare the improved error
estimate with existing numerical estimates. The value of the second order of
the variance expansions allows to get error predictions closer to what is
observed in numerical simulations. It also predicts correctly the necessary SNR
to approximate the error with the CRLB and provides new insight on the
relationship between waveform properties SNR and estimation errors. For example
the timing match filtering becomes optimal only if the SNR is larger than the
kurtosis of the gravitational wave spectrum
Condensation risk – impact of improvements to Part L and robust details on Part C Final report: BD2414
This report summarises the main findings of the project ‘Impacts of Improvements to Part L and Robust Construction Details (RCD) on Part C’. The work consisted of a fieldwork element, undertaken by Leeds Metropolitan University and a modelling element carried out by University College London. Details of the work programme are contained in Appendix 1. The fieldwork consisted of the analysis of design material and site surveys from 16 housing developments constructed to Part L 2002 and adopting the Robust Construction Detail route to compliance. The modelling element of the project sought to identify the extent to which the ‘as built’ details give rise to a significantly increased condensation risk as compared to the relevant ‘standard’ robust construction details, as defined in the guidance. In addition to assessing ‘as built’ performance, the modelling phase of the project has investigated the suitability of the relevant calculation methods used to assess the risk of surface and interstitial condensation and mould growth. This report draws together the important conclusions from the project which has previously been presented in several very detailed interim reports and also for the first time presents the results of a workshop where these results were discussed to obtain industry feedback. The overall conclusions, future work and dissemination plans are also presented
Evaluating the impact of an enhanced energy performance standard on load-bearing masonry domestic construction: Understanding the gap between designed and real performance: lessons from Stamford Brook.
This report is aimed at those with interests in the procurement, design and construction of new dwellings both now and in the coming years as the Government’s increasingly stringent targets for low and zero carbon housing approach. It conveys the results of a research project, carried out between 2001 and 2008, that was designed to evaluate the extent to which low carbon housing standards can be achieved in the context of a large commercial housing development. The research was led by Leeds Metropolitan University in collaboration with University College London and was based on the Stamford Brook development in Altrincham, Cheshire. The project partners were the National Trust, Redrow and Taylor Wimpey and some 60 percent of the planned 700 dwelling development has been completed up to June 2008. As the UK house building industry and its suppliers grapple with the challenges of achieving zero carbon housing by 2016, the lessons arising from this project are timely and of considerable value. Stamford Brook has demonstrated that designing masonry dwellings to achieve an enhanced energy standard is feasible and that a number of innovative approaches, particularly in the area of airtightness, can be successful. The dwellings, as built, exceed the Building Regulations requirements in force at the time but tests on the completed dwellings and longer term monitoring of performance has shown that, overall, energy consumption and carbon emissions, under standard occupancy, are around 20 to 25 percent higher than design predictions. In the case of heat loss, the discrepancy can be much higher. The report contains much evidence of considerable potential but points out that realising the design potential requires a fundamental reappraisal of processes within the industry from design and construction to the relationship with its supply chain and the development of the workforce. The researchers conclude that, even when builders try hard, current mainstream technical and organisational practices together with industry cultures present barriers to consistent delivery of low and zero carbon performance. They suggest that the underlying reasons for this are deeply embedded at all levels of the house building industry. They point out also that without fundamental change in processes and cultures, technological innovations, whether they be based on traditional construction or modern methods are unlikely to reach their full potential. The report sets out a series of wide ranging implications for new housing in the UK, which are given in Chapter 14 and concludes by firmly declaring that cooperation between government, developers, supply chains, educators and researchers will be crucial to improvement. The recommendations in this report are already being put into practice by the researchers at Leeds Metropolitan University and University College London in their teaching and in further research projects. The implications of the work have been discussed across the industry at a series of workshops undertaken in 2008 as part of the LowCarb4Real project (see http://www.leedsmet.ac.uk/as/cebe/projects/lowcarb4real/index.htm). In addition, the learning is having an impact on the work of the developers (Redrow and Taylor Wimpey) who, with remarkable foresight and enthusiasm, hosted the project. This report seeks to make the findings more widely available and is offered for consideration by everyone who has a part to play in making low and zero carbon housing a reality
An evaluation of the hygrothermal performance of 'standard' and 'as built' construction details using steadystate and transient modelling
Accurate assessment of both surface and interstitial condensation risk at the design stage of buildings is of great importance - not just to minimise the damaging effects moisture can cause to building envelopes, but also to contribute to the provision of adequate indoor air quality. Guidance certainly does exist with regards to limiting thermal bridging in order to prevent condensation occurring on new constructions. However, a recent study has provided clear evidence that the reality, both in translating the available guidance into a specific design and in construction on site is often rather different from the 'ideal'. This paper reports on that study and compares and evaluates the hygrothermal performance of construction details for different phases during the building life cycle. The results of both the surface and interstitial condensation risk simulations under both steady-state and transient conditions are presented and discussed. Significant differences in the hygrothermal performance of 'standard' and 'as built' construction details are observed
Adding value and meaning to coheating tests
Purpose: The coheating test is the standard method of measuring the heat loss coefficient of a building, but to be useful the test requires careful and thoughtful execution. Testing should take place in the context of additional investigations in order to achieve a good understanding of the building and a qualitative and (if possible) quantitative understanding of the reasons for any performance shortfall. The paper aims to discuss these issues. Design/methodology/approach: Leeds Metropolitan University has more than 20 years of experience in coheating testing. This experience is drawn upon to discuss practical factors which can affect the outcome, together with supporting tests and investigations which are often necessary in order to fully understand the results. Findings: If testing is approached using coheating as part of a suite of investigations, a much deeper understanding of the test building results. In some cases it is possible to identify and quantify the contributions of different factors which result in an overall performance shortfall. Practical implications: Although it is not practicable to use a fully investigative approach for large scale routine quality assurance, it is extremely useful for purposes such as validating other testing procedures, in-depth study of prototypes or detailed investigations where problems are known to exist. Social implications: Successful building performance testing is a vital tool to achieve energy saving targets. Originality/value: The approach discussed clarifies some of the technical pitfalls which may be encountered in the execution of coheating tests and points to ways in which the maximum value can be extracted from the test period, leading to a meaningful analysis of the building's overall thermal performance
Party Wall Cavity Barrier Effective Edge Seal Testing for ARC Building Solutions Ltd
ARC Building Solutions Ltd manufacture, market and distribute a range of party wall cavity barriers. Part L of the Building Regulations (HM Government, 2013) stipulates that when cavity barriers are used for edge sealing purposes, then the seal must be effective at restricting air flow between the party wall cavity and the external wall cavity or external environment (Figure 1). The Building Control Alliance (2011) describes how an edge seal is to be judged as being effective in a qualitative manner. However, there is currently no standard test for quantitatively demonstrating the effectiveness of edge sealing using a cavity barrier product. ARC Building Solutions Ltd wished to quantify the effectiveness of the edge seal that could be achieved using the Company’s products under test conditions. This information could prove useful when engaging designers, building control bodies and warranty providers. As there is currently no quantitative benchmark for what is deemed to be an effective edge seal this project aimed to compare the performance of a recognised ‘current practice’ solution against ARC Building Solutions Ltd.’s T-Barrier, and as far as possible compare these to an accepted effective edge seal for a number of different party wall and external wall cavity widths. In addition to this comparative testing, this project may also assist in the development and application of a standardised ‘Edge Seal Test’ for which there is understood to be no current standard or specific precedent. Whilst the test rig may not be fully representative of the actual construction of a party wall/external wall junction in situ, it is hoped that the results may provide insight as to how the performance of these products may compare in real building situations
Recommended from our members
Magnetic Resonance Imaging Pilot Study of Intravenous Glyburide in Traumatic Brain Injury.
Pre-clinical studies of traumatic brain injury (TBI) show that glyburide reduces edema and hemorrhagic progression of contusions. We conducted a small Phase II, three-institution, randomized placebo-controlled trial of subjects with TBI to assess the safety and efficacy of intravenous (IV) glyburide. Twenty-eight subjects were randomized and underwent a 72-h infusion of IV glyburide or placebo, beginning within 10 h of trauma. Of the 28 subjects, 25 had Glasgow Coma Scale (GCS) scores of 6-10, and 14 had contusions. There were no differences in adverse events (AEs) or severe adverse events (ASEs) between groups. The magnetic resonance imaging (MRI) percent change at 72-168 h from screening/baseline was compared between the glyburide and placebo groups. Analysis of contusions (7 per group) showed that lesion volumes (hemorrhage plus edema) increased 1036% with placebo versus 136% with glyburide (p = 0.15), and that hemorrhage volumes increased 11.6% with placebo but decreased 29.6% with glyburide (p = 0.62). Three diffusion MRI measures of edema were quantified: mean diffusivity (MD), free water (FW), and tissue MD (MDt), corresponding to overall, extracellular, and intracellular water, respectively. The percent change with time for each measure was compared in lesions (n = 14) versus uninjured white matter (n = 24) in subjects receiving placebo (n = 20) or glyburide (n = 18). For placebo, the percent change in lesions for all three measures was significantly different compared with uninjured white matter (analysis of variance [ANOVA], p < 0.02), consistent with worsening of edema in untreated contusions. In contrast, for glyburide, the percent change in lesions for all three measures was not significantly different compared with uninjured white matter. Further study of IV glyburide in contusion TBI is warranted
- …