1,311 research outputs found

    Examining Obesity Issues

    Get PDF
    This policy brief examines the problems related to over-consumption, excess, and obesity in Missouri. The topic is analyzed, and policy recommendations are explained

    Early Childhood Education as a Crime Prevention Tool

    Get PDF
    Since the mid 1990s, the general revenue funds appropriated for the Department of Corrections has more than tripled, from about 217million(1994)toabout217 million (1994) to about 670 million in 2009. The ripple effects of crime are far reaching: loss of productivity for crime victims and their families, court fees, jail and prison expenses, personal and property damages, and the challenges faced by the children of the incarcerated. All of these carry a hefty monetary and societal price

    Strengthening Missouri's Economic Performance: The Far-Reaching Impact of Investments in Early Childhood Programs

    Get PDF
    The current economic climate is challenging for the state of Missouri and its many industries and businesses. Everyone is seeking investments that will yield significant returns. One important, but frequently overlooked, economic sector is early childhood (EC) programs. Frequently referred to as “child care,” this sector includes early childhood services provided to young children (birth - kindergarten entry). EC programs employ more than 34,000 Missourians in a variety of EC settings

    Accuracy of MRI skeletal age estimation for subjects 12–19. Potential use for subjects of unknown age

    Get PDF
    In forensic practice, there is a growing need for accurate methods of age estimation, especially in the cases of young individuals of unknown age. Age can be estimated through somatic features that are universally considered associated with chronological age. Unfortunately, these features do not always coincide with the real chronological age: for these reasons that age determination is often very difficult. Our aim is to evaluate accuracy of skeletal age estimation using Tomei's MRI method in subjects between 12 and 19 years old for forensic purposes. Two investigators analyzed MRI images of the left hand and wrist of 77 male and 74 female caucasian subjects, without chronic diseases or developmental disorders, whose age ranged from 12 to 19 years. Skeletal maturation was determined by two operators, who analyzed all MRI images separately, in blinded fashion to the chronological age. Inter-rater agreement was measured with Pearson (R (2)) coefficient. One of the examiners repeated the evaluation after 6 months, and intraobserver variation was analyzed. Bland-Altman plots were used to determine mean differences between skeletal and chronological age. Inter-rater agreement Pearson coefficient showed a good linear correlation, respectively, 0.98 and 0.97 in males and females. Bland-Altman analysis demonstrated that the differences between chronological and skeletal age are not significant. Spearman's correlation coefficient showed good correlation between skeletal and chronological age both in females (R (2) = 0.96) and in males (R (2) = 0.94). Our results show that MRI skeletal age is a reproducible method and has good correlation with chronological age

    Signal Intensity Change on Unenhanced T1-Weighted Images in Dentate Nucleus Following Gadobenate Dimeglumine in Patients With and Without Previous Multiple Administrations of Gadodiamide

    Get PDF
    OBJECTIVES: To evaluate the impact of previous administration of gadodiamide and neural tissue gadolinium deposition in patients who received gadobenate dimeglumine. METHODS: Our population included 62 patients who underwent at least three administrations of gadobenate dimeglumine, plus an additional contrast-enhanced last MRI for reference, divided into two groups: group 1, patients who in addition to gadobenate dimeglumine administrations had prior exposure to multiple doses of gadodiamide; group 2, patients without previous exposure to other gadolinium-based contrast agent (GBCAs). Quantitative analysis was performed on the first and last gadobenate dimeglumine MRIs in both groups. Dentate nucleus-to-middle cerebellar peduncle signal intensity ratios (DN/MCP) and relative change (RC) in signal over time were calculated and compared between groups using generalized additive model. RESULTS: Group 1 showed significant increase in baseline and follow-up DN/MCP compared to group 2 (p < 0.0001). The RC DN/MCP showed a non-statistically significant trend towards an increase in patients who underwent previous gadodiamide (p = 0.0735). CONCLUSION: There is increased T1 signal change over time in patients who underwent gadobenate dimeglumine and had received prior gadodiamide compared to those without known exposure to previous gadodiamide. A potentiating effect from prior gadodiamide on subsequent administered gadobenate dimeglumine may occur. KEY POINTS: • Neural gadolinium deposition is associated with multiple administrations of less stable GBCAs. • Less stable GBCA effect on subsequent more stable GBCA administrations is undetermined. • Significant increase of DN/MCP was seen in patients with previous gadodiamide exposure. • RC DN/MCP showed a non-significant increase in patients who received previous gadodiamide. • Potentiating effects from prior gadodiamide on subsequent administered gadobenate dimeglumine may occur.info:eu-repo/semantics/publishedVersio

    MRI of the Liver

    Full text link
    MRI provides comprehensive information on the full range of liver diseases, including congenital abnormalities, benign and malignant focal liver lesions, and diffuse liver disease. This unit presents a protocol that incorporates various types of T1‐and T2‐weighted sequences, including transverse and coronal data acquisition, and the routine use of intravenous gadolinium.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145309/1/cpmia1501.pd

    MRI of the Pancreas

    Full text link
    MRI provides comprehensive information on the full range of pancreatic diseases. This unit presents a protocol incorporating various types of sequences, including transverse and coronal data acquisitions, and with the routine use of intravenous gadolinium.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145318/1/cpmia1801.pd

    The multi-modality cardiac imaging approach to the Athlete's heart: an expert consensus of the European Association of Cardiovascular Imaging

    Get PDF
    The term 'athlete's heart' refers to a clinical picture characterized by a slow heart rate and enlargement of the heart. A multi-modality imaging approach to the athlete's heart aims to differentiate physiological changes due to intensive training in the athlete's heart from serious cardiac diseases with similar morphological features. Imaging assessment of the athlete's heart should begin with a thorough echocardiographic examination. Left ventricular (LV) wall thickness by echocardiography can contribute to the distinction between athlete's LV hypertrophy and hypertrophic cardiomyopathy (HCM). LV end-diastolic diameter becomes larger (>55 mm) than the normal limits only in end-stage HCM patients when the LV ejection fraction is <50%. Patients with HCM also show early impairment of LV diastolic function, whereas athletes have normal diastolic function. When echocardiography cannot provide a clear differential diagnosis, cardiac magnetic resonance (CMR) imaging should be performed. With CMR, accurate morphological and functional assessment can be made. Tissue characterization by late gadolinium enhancement may show a distinctive, non-ischaemic pattern in HCM and a variety of other myocardial conditions such as idiopathic dilated cardiomyopathy or myocarditis. The work-up of athletes with suspected coronary artery disease should start with an exercise ECG. In athletes with inconclusive exercise ECG results, exercise stress echocardiography should be considered. Nuclear cardiology techniques, coronary cardiac tomography (CCT) and/or CMR may be performed in selected cases. Owing to radiation exposure and the young age of most athletes, the use of CCT and nuclear cardiology techniques should be restricted to athletes with unclear stress echocardiography or CMR

    Association between congenital defects in papillary outgrowth and functional obstruction in Crim1 mutant mice

    Get PDF
    Crim1 hypomorphic (Crim1(KST264/KST264)) mice display progressive renal disease characterized by glomerular defects, leaky peritubular vasculature, and progressive interstitial fibrosis. Here we show that 27% of these mice also present with hydronephrosis, suggesting obstructive nephropathy. Dynamic magnetic resonance imaging using Magnevist showed fast development of hypo-intense signal in the kidneys of Crim1(KST264/KST264) mice, suggesting pooling of filtrate within the renal parenchyma. Rhodamine dextran (10 kDa) clearance was also delayed in Crim1(KST264/KST264) mice. Pyeloureteric peristalsis, while present, was less co-ordinated in Crim1(KST264/KST264) mice. However, isolated renal pelvis preparations suggest normal pelvic smooth muscle contractile responses. An analysis of maturation during the immediate postnatal period [postnatal day (P) 0-15] revealed defects in papillary extension in Crim1(KST264/KST264) mice. While Crim1 expression is weak in pelvic smooth muscle, strong expression is seen in the interstitium and loops of Henle of the extending papilla, commencing at the tip of the P1 papilla and disseminating throughout the papilla by P15. These results, as well as implicating Crim1 in papillary extension and pelvic smooth muscle contractility, highlight the previously unrecognized association between defects in papillary development and progression to chronic kidney disease later in life. Copyright (C) 2012 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd

    T1 Signal-Intensity Increase in the Dentate Nucleus after Multiple Exposures to Gadodiamide: Intraindividual Comparison between 2 Commonly Used Sequences

    Get PDF
    BACKGROUND AND PURPOSE: Different T1-weighted sequences have been used for qualitative and quantitative evaluation of T1 signal intensity related to gadolinium deposition in the dentate nucleus in patients who underwent several enhanced MR imaging studies. Our purpose was to perform an intraindividual qualitative and quantitative comparison between T1-weighted spin-echo and 3D magnetization-prepared rapid acquisition of gradient echo sequences in patients who had multiple exposures to gadodiamide. MATERIALS AND METHODS: Our retrospectively selected population included 18 patients who underwent at least 3 administrations of gadodiamide and had a baseline and a final MR imaging performed with both T1-weighted sequences. Qualitative and quantitative analyses were independently performed. Dentate nucleus/middle cerebellar peduncle signal-intensity ratios and signal changes between the baseline and final examinations were compared by using the Wilcoxon signed rank test. Correlation between quantitative and qualitative evaluations was assessed by using a polyserial correlation test. RESULTS: The differences between the 2 sequences for both baseline and last examination dentate nucleus/middle cerebellar peduncle ratios were statistically significant (P = .008 and P = .006, respectively); however, the signal-intensity changes of the ratios with time were not (P = .64). The correlation between the qualitative and quantitative analysis was very strong (near-perfect) (r = 0.9) for MPRAGE and strong (r = 0.63) for spin-echo sequences. CONCLUSIONS: T1-weighted spin-echo and MPRAGE sequences cannot be used interchangeably for qualitative or quantitative analysis of signal intensity in the dentate nucleus in patients who received gadodiamide. Baseline and final examination ratios should be evaluated across time by using the same sequence. Qualitative analysis performed with MPRAGE correlated better with quantitative analysis and may offer advantages over spin-echo sequences for research purposes
    corecore