889 research outputs found
Measurement of the quasi-elastic axial vector mass in neutrino-oxygen interactions
The weak nucleon axial-vector form factor for quasi-elastic interactions is
determined using neutrino interaction data from the K2K Scintillating Fiber
detector in the neutrino beam at KEK. More than 12,000 events are analyzed, of
which half are charged-current quasi-elastic interactions nu-mu n to mu- p
occurring primarily in oxygen nuclei. We use a relativistic Fermi gas model for
oxygen and assume the form factor is approximately a dipole with one parameter,
the axial vector mass M_A, and fit to the shape of the distribution of the
square of the momentum transfer from the nucleon to the nucleus. Our best fit
result for M_A = 1.20 \pm 0.12 GeV. Furthermore, this analysis includes updated
vector form factors from recent electron scattering experiments and a
discussion of the effects of the nucleon momentum on the shape of the fitted
distributions.Comment: 14 pages, 10 figures, 6 table
Performance of emergency surgical front of neck airway access by head and neck surgeons, general surgeons, or anaesthetists:an in situ simulation study
BACKGROUND The “Can’t Intubate Can’t Oxygenate” (CICO) emergency requires urgent front of neck airway access to prevent death. In cases reported to the 4th National Audit Project, the most successful front of neck airway (FONA) was a surgical technique, almost all of which were performed by surgeons. Subsequently, UK guidelines adopted surgical cricothyroidotomy as the preferred emergency surgical FONA technique. Despite regular skills-based training, anaesthetists may still be unwilling to perform an emergency surgical FONA. AIM To compare consultant anaesthetists, head and neck surgeons and general surgeons in a high-fidelity simulated emergency. We hypothesised that head and neck surgeons would successfully execute emergency surgical FONA faster than anaesthetists and general surgeons.
METHODS We recruited 15 consultants from each specialty (total 45). All agreed to participate in an in-situ hi-fidelity simulation of an ‘anaesthetic emergency’. Participants were not told in advance that this would be a CICO scenario.
RESULTS There was no significant difference in total time to successful ventilation between the three groups (median 86 vs. 98 vs. 126.5 seconds, p=0.078). However, anaesthetists completed the emergency surgical FONA procedure significantly faster than general surgeons (median 50 vs. 86 seconds, p=0.018). Despite this strong performance, qualitative data suggested some anaesthetists still believed ‘surgeons’ best placed to perform emergency surgical FONA in a genuine CICO situation.
CONCLUSION Anaesthetists regularly trained in emergency emergency surgical FONA function at levels comparable to head and neck surgeons and should feel empowered to lead this procedure in the event of a CICO emergency
Recommended from our members
Shading Beats Binocular Disparity in Depth from Luminance Gradients: Evidence against a Maximum Likelihood Principle for Cue Combination
Perceived depth is conveyed by multiple cues, including binocular disparity and luminance shading. Depth perception from luminance shading information depends on the perceptual assumption for the incident light, which has been shown to default to a diffuse illumination assumption. We focus on the case of sinusoidally corrugated surfaces to ask how shading and disparity cues combine defined by the joint luminance gradients and intrinsic disparity modulation that would occur in viewing the physical corrugation of a uniform surface under diffuse illumination. Such surfaces were simulated with a sinusoidal luminance modulation (0.26 or 1.8 cy/deg, contrast 20%-80%) modulated either in-phase or in opposite phase with a sinusoidal disparity of the same corrugation frequency, with disparity amplitudes ranging from 0’-20’. The observers’ task was to adjust the binocular disparity of a comparison random-dot stereogram surface to match the perceived depth of the joint luminance/disparitymodulated corrugation target. Regardless of target spatial frequency, the perceived target depth increased with the luminance contrast and depended on luminance phase but was largely unaffected by the luminance disparity modulation. These results validate the idea that human observers can use the diffuse illumination assumption to perceive depth from luminance gradients alone without making an assumption of light direction. For depth judgments with combined cues, the observers gave much greater weighting to the luminance shading than to the disparity modulation of the targets. The results were not well-fit by a Bayesian cue-combination model weighted in proportion to the variance of the measurements for each cue in isolation. Instead, they suggest that the visual system uses disjunctive mechanisms to process these two types of information rather than combining them according to their likelihood ratios
Measurement of the B+ --> p pbar K+ Branching Fraction and Study of the Decay Dynamics
With a sample of 232x10^6 Upsilon(4S) --> BBbar events collected with the
BaBar detector, we study the decay B+ --> p pbar K+ excluding charmonium decays
to ppbar. We measure a branching fraction Br(B+ --> p pbar
K+)=(6.7+/-0.5+/-0.4)x10^{-6}. An enhancement at low ppbar mass is observed and
the Dalitz plot asymmetry suggests dominance of the penguin amplitude in this B
decay. We search for a pentaquark candidate Theta*++ decaying into pK+ in the
mass range 1.43 to 2.00 GeV/c2 and set limits on Br(B+ -->
Theta*++pbar)xBr(Theta*++ --> pK+) at the 10^{-7} level.Comment: 8 pages, 7 postscript figures, submitted to Phys. Rev. D (Rapid
Communications
Search for rare quark-annihilation decays, B --> Ds(*) Phi
We report on searches for B- --> Ds- Phi and B- --> Ds*- Phi. In the context
of the Standard Model, these decays are expected to be highly suppressed since
they proceed through annihilation of the b and u-bar quarks in the B- meson.
Our results are based on 234 million Upsilon(4S) --> B Bbar decays collected
with the BABAR detector at SLAC. We find no evidence for these decays, and we
set Bayesian 90% confidence level upper limits on the branching fractions BF(B-
--> Ds- Phi) Ds*- Phi)<1.2x10^(-5). These results
are consistent with Standard Model expectations.Comment: 8 pages, 3 postscript figues, submitted to Phys. Rev. D (Rapid
Communications
- …
