11 research outputs found

    Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC

    Get PDF
    The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, U.S.A. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of 7 × 6 × 7.2 m3. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components

    Searching for solar KDAR with DUNE

    Get PDF

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3σ (5σ) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3σ level with a 100 kt-MW-yr exposure for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest

    Marital Adjustment

    No full text
    The definition of this construct is one of the most controversial topics in the literature. On the basis of various contributions, marital adjustment can be defined as a multidimensional indicator of the quality of marital relationship. Evolution of the Construct Marital adjustment is one of the most studied dimensions in the couple and family research literature. According to Spanier (1976, p. 15), already by the 1970s, marital adjustment was \u201cprobably the most frequently investigated dependent variable in the field\u201d. Also during the last 30 years, family researchers and scholars have maintained a strong interest on marital adjustment, as an outcome (Shriner 2009). The literature on marital adjustment reveals a variety of factors that are related to the dyadic adjustment (e.g., individual aspects like personality traits, irrational beliefs, and dysfunctional emotions Abbasi 2017; Filipovi\u107 et al. 2016 and relational aspects like romantic attachment and dyadic coping (Young et al. 2017). Over the last decade, a substantial number of studies have focused on the role of personality traits in predicting the quality of adult romantic relationships (Abbasi 2017; Lampis et al. 2018; Rusu et al. 2019)

    Excitotoxic Lesions of the Neostriatum as an Animal Model of Huntington’s Disease

    No full text

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE’s sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-calendar years (kt-MW-CY), where calendar years include an assumption of 57% accelerator uptime based on past accelerator performance at Fermilab. The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 4 σ ( 5 σ ) level with a 66 (100) kt-MW-CY far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters, with a median sensitivity of 3 σ for almost all true δ CP values after only 24 kt-MW-CY. We also show that DUNE has the potential to make a robust measurement of CPV at a 3 σ level with a 100 kt-MW-CY exposure for the maximally CP-violating values δ CP = ± π / 2 . Additionally, the dependence of DUNE’s sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest
    corecore