280 research outputs found

    The LHCb Muon detector commissioning and first running scenarios

    Get PDF
    The LHCb muon detector, part of the first LHCb trigger level (L0), has been built to provide a fast and efficient identification of the muons produced in pp collisions at the LHC. The expected performances are: 95% L0 trigger efficiency within a 25 ns time window and muon identification in L0 with a Pr resolution of 20%. The detector has been built using Multi-Wire Proportional Chambers and Gas Electron Multiplier technology. The chambers are arranged in five stations, interspersed with iron filter placed along the beam pipe. The results obtained in the commissioning of all the installed chambers and the measured performances are presented. The strategies foreseen for the detector calibration, the results of the space and time alignment efforts and few first running scenarios are discussed

    Calibration Strategy and Efficiency measurement of the Muon Identification procedure at LHCb

    Get PDF
    We present a strategy for calibrating with data the LHCb muon identification procedure and for extracting in-situ the performance. Two main calibration samples are used: the inclusive Jψ→ΌΌJ\psi \to \mu\mu decay as a source of muons and the λ(1115.7)→pπ\lambda(1115.7)\to p\pi decay as a source of hadrons decaying and non-decaying in flight. For each of them we describe the selection, the expected purity and the rates for different running scenarios. The distributions extracted from calibration samples are compared with those obtained from a generic b-inclusive sample. An estimate of the precision that can be reached in the evaluation of the muon identification efficiency and misidentification rate is given as a function of the collected statistics

    The Muon Identification Procedure of the LHCb Experiment for the First Data

    Get PDF
    We present a refined muon identification algorithm for the LHCb experiment suitable for the first period of data taking. The new algorithm is robust against possible inefficiencies of the Muon Detector and takes properly into account the momentum dependence, so it can be tuned with calibration samples and exported to signal samples with different momentum spectra without large corrections. The average performance depends on the momentum spectrum of the analyzed sample: with the current simulation we find for tracks with p > 3 GeV/c in a generic b-inclusive sample a muon identification efficiency of 90 % for a misidentification rate of hadrons and electrons of ~2.4 % (~ 1 % excluding pi's and K's decays in flight). Additional rejection power can be obtained by combining in a proper way the informations coming from all the other subdetectors in a global Likelihood: in this case for a muon identification efficiency of 90 % we find a misidentification rate of ~1.8 % (~ 0.8 % excluding pi's and K's decays in flight

    Postural analysis using rasterstereography and inertial measurement units in volleyball players: different roles as indicators of injury predisposition

    Get PDF
    Background and Objectives: Acute and chronic injuries are frequent in volleyball. Biomechanics of sport-specific tasks can influence the risk of injury, which is also related to specific court positions. We investigated posture at raster-stereography, balance, and dynamic tasks using inertial motion units to find differences between roles, which can be predictive of a higher risk of injury. Materials and Methods: We cross-sectionally evaluated amateur volleyball athletes. Participants were divided into roles as outside hitters, setters, middle blockers, and opposite hitters. We excluded the “libero” position from our analysis. Results: Sixteen players were included in the analysis. A statistically significant difference was found in left lower limb stiffness among the outside hitter and setter groups. Conclusions: Differences in stiffness might be related to the different training and the different abilities among the two groups. Raster-stereography is extending its indications and should be implemented for non-invasive postural analysis. The use of inertial motion units provides objective measurements of variables that could go unrecognized within a clinical evaluation; its use should be considered in injury preventive programs

    Performance of the Muon Identification at LHCb

    Full text link
    The performance of the muon identification in LHCb is extracted from data using muons and hadrons produced in J/\psi->\mu\mu, \Lambda->p\pi and D^{\star}->\pi D0(K\pi) decays. The muon identification procedure is based on the pattern of hits in the muon chambers. A momentum dependent binary requirement is used to reduce the probability of hadrons to be misidentified as muons to the level of 1%, keeping the muon efficiency in the range of 95-98%. As further refinement, a likelihood is built for the muon and non-muon hypotheses. Adding a requirement on this likelihood that provides a total muon efficiency at the level of 93%, the hadron misidentification rates are below 0.6%.Comment: 17 pages, 10 figure

    Performance of the LHCb muon system with cosmic rays

    Full text link
    The LHCb Muon system performance is presented using cosmic ray events collected in 2009. These events allowed to test and optimize the detector configuration before the LHC start. The space and time alignment and the measurement of chamber efficiency, time resolution and cluster size are described in detail. The results are in agreement with the expected detector performance.Comment: Submitted to JINST and accepte

    Performance of the LHCb muon system

    Full text link
    The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirementsComment: JINST_015P_1112 201

    Search for CP violation in D+→ϕπ+ and D+s→K0Sπ+ decays

    Get PDF
    A search for CP violation in D + → ϕπ + decays is performed using data collected in 2011 by the LHCb experiment corresponding to an integrated luminosity of 1.0 fb−1 at a centre of mass energy of 7 TeV. The CP -violating asymmetry is measured to be (−0.04 ± 0.14 ± 0.14)% for candidates with K − K + mass within 20 MeV/c 2 of the ϕ meson mass. A search for a CP -violating asymmetry that varies across the ϕ mass region of the D + → K − K + π + Dalitz plot is also performed, and no evidence for CP violation is found. In addition, the CP asymmetry in the D+s→K0Sπ+ decay is measured to be (0.61 ± 0.83 ± 0.14)%

    Differential branching fraction and angular analysis of the decay B0→K∗0ÎŒ+Ό−

    Get PDF
    The angular distribution and differential branching fraction of the decay B 0→ K ∗0 ÎŒ + ÎŒ − are studied using a data sample, collected by the LHCb experiment in pp collisions at s√=7 TeV, corresponding to an integrated luminosity of 1.0 fb−1. Several angular observables are measured in bins of the dimuon invariant mass squared, q 2. A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q20=4.9±0.9GeV2/c4 , where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions

    Search for CP violation in D+→K−K+π+D^{+} \to K^{-}K^{+}\pi^{+} decays

    Get PDF
    A model-independent search for direct CP violation in the Cabibbo suppressed decay D+→K−K+π+D^+ \to K^- K^+\pi^+ in a sample of approximately 370,000 decays is carried out. The data were collected by the LHCb experiment in 2010 and correspond to an integrated luminosity of 35 pb−1^{-1}. The normalized Dalitz plot distributions for D+D^+ and D−D^- are compared using four different binning schemes that are sensitive to different manifestations of CP violation. No evidence for CP asymmetry is found.Comment: 13 pages, 8 figures, submitted to Phys. Rev.
    • 

    corecore