24 research outputs found

    Neutral pion and η\eta meson production in proton-proton collisions at s=0.9\sqrt{s}=0.9 TeV and s=7\sqrt{s}=7 TeV

    Get PDF
    The first measurements of the invariant differential cross sections of inclusive π0\pi^0 and η\eta meson production at mid-rapidity in proton-proton collisions at s=0.9\sqrt{s}=0.9 TeV and s=7\sqrt{s}=7 TeV are reported. The π0\pi^0 measurement covers the ranges 0.4<pT<70.4<p_T<7 GeV/cc and 0.3<pT<250.3<p_T<25 GeV/cc for these two energies, respectively. The production of η\eta mesons was measured at s=7\sqrt{s}=7 TeV in the range 0.4<pT<150.4<p_T<15 GeV/cc. Next-to-Leading Order perturbative QCD calculations, which are consistent with the π0\pi^0 spectrum at s=0.9\sqrt{s}=0.9 TeV, overestimate those of π0\pi^0 and η\eta mesons at s=7\sqrt{s}=7 TeV, but agree with the measured η/π0\eta/\pi^0 ratio at s=7\sqrt{s}=7 TeV.Comment: 17 pages, 5 captioned figures, 2 tables, authors from page 12, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/310

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Health status after transcatheter aortic valve replacement in patients at extreme surgical risk: Results from the CoreValve U.S. Trial

    Get PDF
    Objectives The purpose of this study was to characterize health status outcomes after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis among patients at extreme surgical risk and to identify pre-procedural patient characteristics associated with a poor outcome. Background For many patients considering TAVR, improvement in quality of life may be of even greater importance than prolonged survival. Methods Patients with severe, symptomatic aortic stenosis who were considered to be at prohibitive risk for surgical aortic valve replacement were enrolled in the single-arm CoreValve U.S. Extreme Risk Study. Health status was assessed at baseline and at 1, 6, and 12 months after TAVR using the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Short Form-12, and the EuroQol-5D. The overall summary scale of the KCCQ (range 0 to 100; higher scores = better health) was the primary health status outcome. A poor outcome after TAVR was defined as death, a KCCQ overall summary score (OS) <45, or a decline in KCCQ-OS of 10 points at 6-month follow-up. Results A total of 471 patients underwent TAVR via the transfemoral approach, of whom 436 (93%) completed the baseline health status survey. All health status measures demonstrated considerable impairment at baseline. After TAVR, there was substantial improvement in both disease-specific and generic health status measures, with an increase in the KCCQ-OS of 23.9 points (95% confidence interval [CI]: 20.3 to 27.5 points) at 1 month, 27.4 points (95% CI: 24.2 to 30.6 points) at 6 months, 27.4 points (95% CI: 24.1 to 30.8 points) at 12 months, along with substantial increases in Short Form-12 scores and EuroQol-5D utilities (all p < 0.003 compared with baseline). Nonetheless, 39% of patients had a poor outcome after TAVR. Baseline factors independently associated with poor outcome included wheelchair dependency, lower mean aortic valve gradient, prior coronary artery bypass grafting, oxygen dependency, very high predicted mortality with surgical aortic valve replacement, and low serum albumin. Conclusions Among patients with severe aortic stenosis, TAVR with a self-expanding bioprosthesis resulted in substantial improvements in both disease-specific and generic health-related quality of life, but there remained a large minority of patients who died or had very poor quality of life despite TAVR. Predictive models based on a combination of clinical factors as well as disability and frailty may provide insight into the optimal patient population for whom TAVR is beneficial. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902
    corecore