9,262 research outputs found

    Photonic polarization gears for ultra-sensitive angular measurements

    Get PDF
    Quantum metrology bears a great promise in enhancing measurement precision, but is unlikely to become practical in the near future. Its concepts can nevertheless inspire classical or hybrid methods of immediate value. Here, we demonstrate NOON-like photonic states of m quanta of angular momentum up to m=100, in a setup that acts as a "photonic gear", converting, for each photon, a mechanical rotation of an angle {\theta} into an amplified rotation of the optical polarization by m{\theta}, corresponding to a "super-resolving" Malus' law. We show that this effect leads to single-photon angular measurements with the same precision of polarization-only quantum strategies with m photons, but robust to photon losses. Moreover, we combine the gear effect with the quantum enhancement due to entanglement, thus exploiting the advantages of both approaches. The high "gear ratio" m boosts the current state-of-the-art of optical non-contact angular measurements by almost two orders of magnitude.Comment: 10 pages, 4 figures, + supplementary information (10 pages, 3 figures

    A Novel Manufacturing Technology for RF MEMS Devices on Ceramic Substrates

    Get PDF
    Microelectromechanical systems are often used for their enormous capability and good qualities in T/R modules especially for space modular applications. High isolation and very low insertion loss are guaranteed by their intrinsic working principle. This is a very robust, flexible, and low-cost technology, and it provides high reliability, good reproducibility, and complete fulfillment of technical requirements

    Response of microchannel plates in ionization mode to single particles and electromagnetic showers

    Full text link
    Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution, microchannel plates (MCPs) are good candidate detectors for this goal. We report on the response of MCPs, used as secondary emission detectors, to single relativistic particles and to electromagnetic showers. Several prototypes, with different geometries and characteristics, were exposed to particle beams at the INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency are measured for single particles and as a function of the multiplicity of particles. Efficiencies between 50% and 90% to single relativistic particles are reached, and up to 100% in presence of a large number of particles. Time resolutions between 20ps and 30ps are obtained.Comment: 20 pages, 9 figures. Paper submitted to NIM

    Retrospective Chart Review of Dabrafenib Plus Trametinib in Patients with Metastatic BRAF V600-Mutant Melanoma Treated in the Individual Patient Program (DESCRIBE Italy)

    Get PDF
    Background: Real-world data on extended follow-up of patients with BRAF V600-mutant metastatic melanoma are limited. We investigated dabrafenib plus trametinib (dab + tram) outside of a clinical trial setting (Individual Patient Program; DESCRIBE Italy). Objective: To describe the baseline features, treatment patterns, efficacy, and safety outcomes in patients with BRAF V600-mutant unresectable or metastatic melanoma who had received dab + tram as part of the Managed Access Program (MAP) in Italy. Patients and methods: An observational, retrospective chart review was conducted in Italian patients with BRAF V600-mutant unresectable stage III/IV melanoma receiving dab + tram as part of the MAP. Baseline features, treatment patterns, efficacy, and safety outcomes were evaluated. Results: Overall, 499 patients were included in this analysis. BRAF V600E mutation was seen in 81.4% of patients. Overall response rate achieved in 243 of the 390 evaluable patients was 62.3% (95% CI 57.5-67.1). Median progression-free survival (PFS) was 9.3 months (95% CI 8.6-10.6). Subgroup analyses revealed that patients with normal lactate dehydrogenase (LDH) and ≤ three metastatic sites without brain metastases at baseline had better outcomes. With normal LDH at baseline, median PFS for patients with one or two metastatic sites other than cerebral was 18 months. No new safety signals were observed. Treatment was permanently discontinued because of treatment-emergent adverse events (TEAEs) in 9.2% of patients, and pyrexia (27.3%) was the most common TEAE, with a lower incidence than that in the phase 3 studies of dab + tram. Conclusion: Treatment of BRAF V600E-mutant metastatic melanoma with dab + tram in the real-world setting was effective and safe, including the unselected population with several patients having a high tumor burden - concordant with the results of the pivotal phase 3 studies of dab + tram

    Rate of Decline of the Oriental White-Backed Vulture Population in India Estimated from a Survey of Diclofenac Residues in Carcasses of Ungulates

    Get PDF
    The non-steroidal anti-inflammatory drug diclofenac is a major cause of the rapid declines in the Indian subcontinent of three species of vultures endemic to South Asia. The drug causes kidney failure and death in vultures. Exposure probably arises through vultures feeding on carcasses of domesticated ungulates treated with the drug. However, before the study reported here, it had not been established from field surveys of ungulate carcasses that a sufficient proportion was contaminated to cause the observed declines. We surveyed diclofenac concentrations in samples of liver from carcasses of domesticated ungulates in India in 2004–2005. We estimated the concentration of diclofenac in tissues available to vultures, relative to that in liver, and the proportion of vultures killed after feeding on a carcass with a known level of contamination. We assessed the impact of this mortality on vulture population trend with a population model. We expected levels of diclofenac found in ungulate carcasses in 2004–2005 to cause oriental white-backed vulture population declines of 80–99% per year, depending upon the assumptions used in the model. This compares with an observed rate of decline, from road transect counts, of 48% per year in 2000–2003. The precision of the estimate based upon carcass surveys is low and the two types of estimate were not significantly different. Our analyses indicate that the level of diclofenac contamination found in carcasses of domesticated ungulates in 2004–2005 was sufficient to account for the observed rapid decline of the oriental white-backed vulture in India. The methods we describe could be used again to assess changes in the effect on vulture population trend of diclofenac and similar drugs. In this way, the effectiveness of the recent ban in India on the manufacture and importation of diclofenac for veterinary use could be monitored

    Improving additive manufacturing performance by build orientation optimization

    Get PDF
    Additive manufacturing (AM) is an emerging type of production technology to create three-dimensional objects layer-by-layer directly from a 3D CAD model. AM is being extensively used in several areas by engineers and designers. Build orientation is a critical issue in AM since it is associated with the part accuracy, the number of supports required and the processing time to produce the object. This paper presents an optimization approach to solve the part build orientation problem taking into account some characteristics or measures that can affect the accuracy of the part, namely the volumetric error, the support area, the staircase effect, the build time, the surface roughness and the surface quality. A global optimization method, the Electromagnetism-like algorithm, is used to solve the part build orientation problem.The authors are grateful to the anonymous referees for their fruitfulcomments and suggestions. This work has been supported and developed under the FIBR3Dproject - Hybrid processes based on additive manufacturing of composites with long or shortfibers reinforced thermoplastic matrix (POCI-01-0145-FEDER-016414), supported by theLisbon Regional Operational Programme 2020, under the PORTUGAL 2020 PartnershipAgreement, through the European Regional Development Fund (ERDF). This work hasbeen also supported by national funds through FCT - Funda ̧c ̃ao para a Ciˆencia e Tecnologiawithin the Project Scope: UID/CEC/00319/201

    Reconstruction of the gravitational wave signal h(t)h(t) during the Virgo science runs and independent validation with a photon calibrator

    Full text link
    The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series h(t)h(t) from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the h(t)h(t) signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed h(t)h(t) signal and the associated uncertainties. The uncertainties of the h(t)h(t) time series are estimated to be 8% in amplitude. The uncertainty of the phase of h(t)h(t) is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 μ\mus at high frequency. A bias lower than 4μs4\,\mathrm{\mu s} and depending on the sky direction of the GW is also present.Comment: 35 pages, 16 figures. Accepted by CQ

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered
    corecore