22 research outputs found

    Electric Cell-Substrate Impedance Sensing of Cellular Effects under Hypoxic Conditions and Carbonic Anhydrase Inhibition

    Get PDF
    Tumor hypoxia provides a dynamic environment for the cancer cells to thrive and metastasize. Evaluation of cell growth, cell-cell, and cell surface interactions in hypoxic conditions is therefore highly needed in the establishment of treatment options. Electric cell-substrate impedance sensing (ECIS) has been traditionally used in the evaluation of cellular platforms as a real-time, label-free impedance-based method to study the activities of cells grown in tissue cultures, but its application for hypoxic environments is seldom reported. We present real-time evaluation of hypoxia-induced bioeffects with a focus on hypoxic pH regulation of tumor environment. To this end, multiparametric real-time bioanalytical platform using electrical impedance spectroscopy (EIS) and human colon cancer HT-29 cells is advanced. A time series of EIS data enables monitoring with high temporal resolution the alterations occurring within the cell layer, especially at the cell-substrate level. We reveal the dynamic changes of cellular processes during hypoxic conditions and in response to application of acetazolamide (AZA), a carbonic anhydrase inhibitor. Optical evaluation and pH assessment complemented the electrical analysis towards establishing a pattern of cellular changes. The proposed bioanalytical platform indicates wide applicability towards evaluation of bioeffects of hypoxia at cellular level

    Development of a highly specific amine-terminated aptamer functionalized surface plasmon resonance biosensor for blood protein detection

    Get PDF
    This paper presents a generally applicable approach for the highly specific detection of blood proteins. Thrombin and thrombin-binding aptamers are chosen for demonstration purposes. The sensor was prepared by immobilizing amine-terminated aptamers onto a gold modified surface using a two-step self-assembled monolayer (SAM) immobilization technique and the physical detection is performed using Surface Plasmon Resonance (SPR). The developed sensor has an optimal detectable range of 5–1000 nM and the results show the sensor has good reversibility, sensitivity and selectivity. Furthermore, the sensor shows the potential of being improved and standardized for direct detection of other blood proteins for clinical applications

    Evaluation of the structure–activity relationship of thrombin with thrombin binding aptamers by voltammetry and atomic force microscopy

    Get PDF
    The structure–activity relationship of the complex between thrombin and thrombin binding aptamers (TBA) was evaluated by differential pulse voltammetry at a glassy carbon electrode and atomic force microscopy at a highly oriented pyrolytic graphite electrode. The effects on the interaction with thrombin of TBA primary and secondary structures as well as of its folding properties in the presence of alkaline metals were investigated. The complex between thrombin and single stranded aptamers involved the coiling of the single stranded molecules around thrombin structure leading to the formation of a robust TBA–thrombin complex that maintains the symmetry and conformation of the thrombin molecule. Monitoring both thrombin and TBA oxidation peaks, showed that the thrombin oxidation peaks occur at more positive potentials after TBA–thrombin complex formation. In the presence of K+ ions, the aptamers fold into quadruplex structures that facilitate the interaction with thrombin molecules. The TBA–thrombin complex adsorbs at the surface with the aptamer quadruplex always in preferential contact with the surface, and the thrombin molecules on top of the aptamer quadruplex structure, thus being less accessible to the electrode surface leading to the occurrence of thrombin oxidation peaks at less positive potentials

    High-resolution impedance mapping using electrically activated quantitative phase imaging

    No full text
    Retrieving electrical impedance maps at the nanoscale rapidly via nondestructive inspection with a high signal-to noise ratio is an unmet need, likely to impact various applications from biomedicine to energy conversion. In this study, we develop a multimodal functional imaging instrument that is characterized by the dual capability of impedance mapping and phase quantitation, high spatial resolution, and low temporal noise. To achieve this, we advance a quantitative phase imaging system, referred to as epi-magnified image spatial spectrum microscopy combined with electrical actuation, to provide complementary maps of the optical path and electrical impedance. We demonstrate our system with high-resolution maps of optical path differences and electrical impedance variations that can distinguish nanosized, semi-transparent, structured coatings involving two materials with relatively similar electrical properties. We map heterogeneous interfaces corresponding to an indium tin oxide layer exposed by holes with diameters as small as ~550 nm in a titanium (dioxide) over-layer deposited on a glass support. We show that electrical modulation during the phase imaging of a macro-electrode is decisive for retrieving electrical impedance distributions with submicron spatial resolution and beyond the limitations of electrode-based technologies (surface or scanning technologies). The findings, which are substantiated by a theoretical model that fits the experimental data very well enable achieving electro-optical maps with high spatial and temporal resolutions. The virtues and limitations of the novel optoelectrochemical method that provides grounds for a wider range of electrically modulated optical methods for measuring the electric field locally are critically discussed

    Real time SPR assessment of the structural changes of adaptive dynamic constitutional frameworks as a new route for sensing

    No full text
    International audienceCross linked gold-dynamic constitutional frameworks (DCFs) are functional materials of potential relevance for biosensing applications, given their adaptivity and high responsivity against various external stimuli (such as pH, temperature) or specific interactions with biomolecules (enzymes or DNA) via internal constitutional dynamics. However, characterization and assessment of their dynamic conformational changes in response to external stimuli has never been reported. This study proves the capability of Surface Plasmon Resonance (SPR) assays to analyze the adaptive structural modulation of a functional matrix encompassing 3D gold-dynamic constitutional frameworks (Au-DCFs) when exposed to pH variations, as external stimuli. We analyze Au-DCFs formed from Au nano-particles, (AuNP) connected through constitutionally dynamic polymers, dynamers, with multiple functionalities. For increased generality of this proof-ofconcept assay, Au-DCFs, involving DCFs designed from 1,3,5-benzene-tricarbaldehyde (BTA) connecting centers and polyethylene glycol (PEG) connectors, are covalently attached to standard SPR sensing chips (Au nanolayers, carboxyl terminated or with carboxymethyl dextran, CMD toplayer) and analyzed using state-of-the art SPR instrumentation. The SPR effects of the distance 24 from the Au-DCFs matrix to the Au nanolayer of the sensing chip as well as of Au-DCFs thickness 25 were investigated. This study reveals the SPR response, augmented by the AuNP, to the confor-26 mational change, i.e. shrinkage, of the Dynamer & AuNP matrix when decreasing the pH and 27 provides an unexplored insight on the sensing applicability of SPR real-time analysis of adaptive 28 functional materials

    Complementarity of EIS and SPR to Reveal Specific and Nonspecific Binding When Interrogating a Model Bioaffinity Sensor; Perspective Offered by Plasmonic Based EIS

    No full text
    The present work compares the responses of a model bioaffinity sensor based on a dielectric functionalization layer, in terms of specific and nonspecific binding, when interrogated simultaneously by Surface Plasmon Resonance (SPR), non-Faradaic Electrochemical Impedance Spectroscopy (EIS), and Plasmonic based-EIS (P-EIS). While biorecognition events triggered a sensitive SPR signal, the related EIS response was rather negligible. Contrarily, even a limited nonspecific adsorption onto the surface of the metallic electrode, allowed by the intrinsic imperfect compactness of the functionalization layers, was signaled by EIS and not by SPR. The source of this finding has been addressed from both theoretical and experimental perspectives, demonstrating that EIS signals are mainly sensitive to adsorptions that alter the current pathway through defects of the functionalization layer exposing the electrode. These observations are of importance for those developing biosensors analyzed by SPR, EIS, or the novel combination of the two methods (P-EIS). A possible application of the observed complementarity of the two methods, namely assessment of sample purity in respect to a target analyte is highlighted. Moreover, the possibility of false-positive EIS responses (determined by nonspecific binding) when assessing samples containing complex matrices or consisting of small molecular weight analytes is emphasized

    High spatial resolution electrochemical biosensing using reflected light microscopy

    No full text
    If the analyte does not only change the electrochemical but also the optical properties of the electrode/ solution interface, the spatial resolution of an electrochemical sensor can be substantially enhanced by combining the electrochemical sensor with optical microscopy. In order to demonstrate this, electrochemical biosensors for the detection of hydrogen peroxide and glucose were developed by drop casting enzyme and redox polymer mixtures onto planar, optically transparent electrodes. These biosensors generate current signals proportional to the analyte concentration via a reaction sequence which ultimately changes the oxidation state of the redox polymer. Images of the interface of these biosensors were acquired using bright field reflected light microscopy (BFRLM). Analysis showed that the intensity of these images is higher when the redox polymer is oxidized than when it is reduced. It also revealed that the time needed for the redox polymer to change oxidation state can be assayed optically and is dependent on the concentration of the analyte. By combining the biosensor for hydrogen peroxide detection with BFRLM, it was possible to determine hydrogen peroxide in concentrations as low as 12.5 μM with a spatial resolution of 12 μm × 12 μm, without the need for the fabrication of microelectrodes of these dimensions

    Quantitative assessment of specific carbonic anhydrase inhibitors effect on hypoxic cells using electrical impedance assays

    No full text
    <p>Carbonic anhydrase IX (CA IX) is an important orchestrator of hypoxic tumour environment, associated with tumour progression, high incidence of metastasis and poor response to therapy. Due to its tumour specificity and involvement in associated pathological processes: tumourigenesis, angiogenesis, inhibiting CA IX enzymatic activity has become a valid therapeutic option. Dynamic cell-based biosensing platforms can complement cell-free and end-point analyses and supports the process of design and selection of potent and selective inhibitors. In this context, we assess the effectiveness of recently emerged CA IX inhibitors (sulphonamides and sulphocoumarins) and their antitumour potential using an electrical impedance spectroscopy biosensing platform. The analysis allows discriminating between the inhibitory capacities of the compounds and their inhibition mechanisms. Microscopy and biochemical assays complemented the analysis and validated impedance findings establishing a powerful biosensing tool for the evaluation of carbonic anhydrase inhibitors potency, effective for the screening and design of anticancer pharmacological agents.</p

    Open-source, high-throughput ultrasound treatment chamber

    No full text
    Studying the effects of ultrasound on biological cells requires extensive knowledge of both the physical ultrasound and cellular biology. Translating knowledge between these fields can be complicated and time consuming. With the vast range of ultrasonic equipment available, nearly every research group uses different or unique devices. Hence, recreating the experimental conditions and results may be expensive or difficult. For this reason, we have developed devices to combat the common problems seen in state-of-the-art biomedical ultrasound research. In this paper, we present the design, fabrication, and characterisation of an open-source device that is easy to manufacture, allows for parallel sample sonication, and is highly reproducible, with complete acoustic calibration. This device is designed to act as a template for sample sonication experiments. We demonstrate the fabrication technique for devices designed to sonicate 24-well plates and OptiCell™ using three-dimensional (3D) printing and low-cost consumables. We increased the pressure output by electrical impedance matching of the transducers using transmission line transformers, resulting in an increase by a factor of 3.15. The devices cost approximately €220 in consumables, with a major portion attributed to the 3D printing, and can be fabricated in approximately 8 working hours. Our results show that, if our protocol is followed, the mean acoustic output between devices has a variance of &lt;1%. We openly provide the 3D files and operation software allowing any laboratory to fabricate and use these devices at minimal cost and without substantial prior know-ho
    corecore