77 research outputs found
Electromagnetic and Hadron Calorimeters in the MIPP Experiment
The purpose of the MIPP experiment is to study the inclusive production of
photons, pions, kaons and nucleons in pi, K and p interactions on various
targets using beams from the Main Injector at Fermilab. The function of the
calorimeters is to measure the production of forward-going neutrons and
photons. The electromagnetic calorimeter consist of 10 lead plates interspersed
with proportional chambers. It was followed by the hadron calorimeter with 64
steel plates interspersed with scintillator. The data presented were collected
with a variety of targets and beam momenta from 5 GeV/c to 120 GeV/c. The
energy calibration of both calorimeters with electrons, pions, kaons, and
protons is discussed. The resolution for electrons was found to be
0.27/sqrt(E), and for hadrons the resolution was 0.554/sqrt(E) with a constant
term of 2.6%. The performance of the calorimeters was tested on a neutron
sample
Theoretical study of lepton events in the atmospheric neutrino experiments at SuperK
Super-Kamiokande has reported the results for the lepton events in the
atmospheric neutrino experiment. These results have been presented for a 22.5kT
water fiducial mass on an exposure of 1489 days, and the events are divided
into sub-GeV, multi-GeV and PC events. We present a study of nuclear medium
effects in the sub-GeV energy region of atmospheric neutrino events for the
quasielastic scattering, incoherent and coherent pion production processes, as
they give the most dominant contribution to the lepton events in this energy
region. We have used the atmospheric neutrino flux given by Honda et al. These
calculations have been done in the local density approximation. We take into
account the effect of Pauli blocking, Fermi motion, Coulomb effect,
renormalization of weak transition strengths in the nuclear medium in the case
of the quasielastic reactions. The inelastic reactions leading to production of
leptons along with pions is calculated in a - dominance model by
taking into account the renormalization of properties in the nuclear
medium and the final state interaction effects of the outgoing pions with the
residual nucleus. We present the results for the lepton events obtained in our
model with and without nuclear medium effects, and compare them with the Monte
Carlo predictions used in the simulation and the experimentally observed events
reported by the Super-Kamiokande collaboration.Comment: 23 pages, 13 figure
Volume I. Introduction to DUNE
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay—these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. This TDR is intended to justify the technical choices for the far detector that flow down from the high-level physics goals through requirements at all levels of the Project. Volume I contains an executive summary that introduces the DUNE science program, the far detector and the strategy for its modular designs, and the organization and management of the Project. The remainder of Volume I provides more detail on the science program that drives the choice of detector technologies and on the technologies themselves. It also introduces the designs for the DUNE near detector and the DUNE computing model, for which DUNE is planning design reports. Volume II of this TDR describes DUNE\u27s physics program in detail. Volume III describes the technical coordination required for the far detector design, construction, installation, and integration, and its organizational structure. Volume IV describes the single-phase far detector technology. A planned Volume V will describe the dual-phase technology
Highly-parallelized simulation of a pixelated LArTPC on a GPU
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described
Deep Underground Neutrino Experiment (DUNE), far detector technical design report, volume III: DUNE far detector technical coordination
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay—these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module
Development of real-time plasma analysis and control algorithms for the TCV tokamak using Simulink
One of the key features of the new digital plasma control system installed on the TCV tokamak is the possibility to rapidly design, test and deploy real-time algorithms. With this flexibility the new control system has been used for a large number of new experiments which exploit TCV's powerful actuators consisting of 16 individually controllable poloidal field coils and 7 real-time steerable electron cyclotron (EC) launchers. The system has been used for various applications, ranging from event-based real-time MHD control to real-time current diffusion simulations. These advances have propelled real-time control to one of the cornerstones of the TCV experimental program. Use of the Simulink graphical programming language to directly program the control system has greatly facilitated algorithm development and allowed a multitude of different algorithms to be deployed in a short time. This paper will give an overview of the developed algorithms and their application in physics experiments
Outcomes of Nonagenarians with Acute Ischemic Stroke Treated with Intravenous Thrombolytics
BackgroundNonagenarians are under-represented in thrombolytic trials for acute ischemic stroke (AIS). The effectiveness of intravenous thrombolytics in nonagenarians in terms of safety and outcome is not well established.Materials and MethodsWe used a multinational registry to identify patients aged 90 years or older with good baseline functional status who presented with AIS. Differences in outcomes—disability level at 90 days, frequency of symptomatic intracerebral hemorrhage (sICH), and mortality—between patients who did and did not receive thrombolytics were assessed using multivariable logistic regression, adjusted for prespecified prognostic factors. Coarsened exact matching (CEM) was utilized before evaluating outcome by balancing both groups in the sensitivity analysis.ResultsWe identified 227 previously independent nonagenarians with AIS; 122 received intravenous thrombolytics and 105 did not. In the unmatched cohort, ordinal analysis showed a significant treatment effect (adjusted common odds ratio [OR]: .61, 95% confidence interval [CI]: .39-.96). There was an absolute difference of 8.1% in the rate of excellent outcome in favor of thrombolysis (17.4% versus 9.3%; adjusted ratio: .30, 95% CI: .12-.77). Rates of sICH and in-hospital mortality were not different. Similarly, in the matched cohort, CEM analysis showed a shift in the primary outcome distribution in favor of thrombolysis (adjusted common OR: .45, 95% CI: .26-.76).ConclusionsNonagenarians treated with thrombolytics showed lower stroke-related disability at 90 days than those not treated, without significant difference in sICH and in-hospital mortality rates. These observations cannot exclude a residual confounding effect, but provide evidence that thrombolytics should not be withheld from nonagenarians because of age alone
- …