161 research outputs found

    Minkowski-Weyl teorém

    Get PDF
    Katedra aplikované matematikyDepartment of Applied MathematicsMatematicko-fyzikální fakultaFaculty of Mathematics and Physic

    Effect of the CRADLE vital signs alert device intervention on referrals for obstetric haemorrhage in low-middle income countries: a secondary analysis of a stepped- wedge cluster-randomised control trial.

    Full text link
    BACKGROUND: Obstetric haemorrhage is the leading cause of maternal death worldwide, 99% of which occur in low and middle income countries. The majority of deaths and adverse events are associated with delays in identifying compromise and escalating care. Management of severely compromised pregnant women may require transfer to tertiary centres for specialised treatment, therefore early recognition is vital for efficient management. The CRADLE vital signs alert device accurately measures blood pressure and heart rate, calculates the shock index (heart rate divided by systolic blood pressure) and alerts the user to compromise through a traffic light system reflecting previously validated shock index thresholds. METHODS: This is a planned secondary analysis of data from the CRADLE-3 trial from ten clusters across Africa, India and Haiti where the device and training package were randomly introduced. Referral data were prospectively collected for a 4-week period before, and a 4-week period 3 months after implementation. Referrals from primary or secondary care facilities to higher level care for any cause were recorded. The denominator was the number of women seen for maternity care in these facilities. RESULTS: Between April 1 2016 and Nov 30th, 2017 536,223 women attended maternity care facilities. Overall, 3.7% (n = 2784/74,828) of women seen in peripheral maternity facilities were referred to higher level care in the control period compared to 4.4% (n = 3212/73,371) in the intervention period (OR 0.89; 0.39-2.05) (data for nine sites that were able to collect denominator). Of these 0.29% (n = 212) pre-intervention and 0.16% (n = 120) post-intervention were referred to higher-level facilities for maternal haemorrhage. Although overall referrals did not significantly reduce there was a significant reduction in referrals for obstetric haemorrhage (OR 0.56 (0.39-0.65) following introduction of the device with homogeneity (i-squared 26.1) between sites. There was no increase in any bleeding-related morbidity (maternal death or emergency hysterectomy). CONCLUSIONS: Referrals for obstetric haemorrhage reduced following implementation of the CRADLE Vital Signs Alert Device, occurring without an increase in maternal death or emergency hysterectomy. This demonstrates the potential benefit of shock index in management pathways for obstetric haemorrhage and targeting limited resources in low- middle- income settings. TRIAL REGISTRATION: This study is registered with the ISRCTN registry, number ISRCTN41244132 (02/02/2016)

    Disability rights and robotics: Co-producing futures

    Get PDF
    This project brought together a team of 25 co-researchers from the University of the West of England, Fairfield Farm College and Wiltshire Centre of Independent Living. The co-researchers are a diverse group including disabled people, carers, students, and academics from social work, psychology and sociology to robotics. Our research team demonstrates a wealth of experiences as some members had both lived experience of disability, in addition to being involved in teaching, learning and research. The research question for the project was:How can robotic technologies support disability rights? Rights are about everyday opportunities to live life to the full, human rights that everyone is entitled to (The Convention on the Rights of Persons with Disabilities (CRPD) 2009 (Enable.un.org, 2019). In this time of rapid social change to our social and work lives, relationships and leisure, there are new technologies that might support disability rights like ‘driverless cars’, smart phones, social media and new robotic technologies. The project had two aims:•to identify priority research questions into disability rights and robotics•to develop the co-production process for future researc

    Intraspecific Correlations of Basal and Maximal Metabolic Rates in Birds and the Aerobic Capacity Model for the Evolution of Endothermy

    Get PDF
    The underlying assumption of the aerobic capacity model for the evolution of endothermy is that basal (BMR) and maximal aerobic metabolic rates are phenotypically linked. However, because BMR is largely a function of central organs whereas maximal metabolic output is largely a function of skeletal muscles, the mechanistic underpinnings for their linkage are not obvious. Interspecific studies in birds generally support a phenotypic correlation between BMR and maximal metabolic output. If the aerobic capacity model is valid, these phenotypic correlations should also extend to intraspecific comparisons. We measured BMR, Msum (maximum thermoregulatory metabolic rate) and MMR (maximum exercise metabolic rate in a hop-flutter chamber) in winter for dark-eyed juncos (Junco hyemalis), American goldfinches (Carduelis tristis; Msum and MMR only), and black-capped chickadees (Poecile atricapillus; BMR and Msum only) and examined correlations among these variables. We also measured BMR and Msum in individual house sparrows (Passer domesticus) in both summer, winter and spring. For both raw metabolic rates and residuals from allometric regressions, BMR was not significantly correlated with either Msum or MMR in juncos. Moreover, no significant correlation between Msum and MMR or their mass-independent residuals occurred for juncos or goldfinches. Raw BMR and Msum were significantly positively correlated for black-capped chickadees and house sparrows, but mass-independent residuals of BMR and Msum were not. These data suggest that central organ and exercise organ metabolic levels are not inextricably linked and that muscular capacities for exercise and shivering do not necessarily vary in tandem in individual birds. Why intraspecific and interspecific avian studies show differing results and the significance of these differences to the aerobic capacity model are unknown, and resolution of these questions will require additional studies of potential mechanistic links between minimal and maximal metabolic output

    Moving beyond silos: How do we provide distributed personalized medicine to pregnant women everywhere at scale? Insights from PRE-EMPT.

    Get PDF
    While we believe that pre-eclampsia matters-because it remains a leading cause of maternal and perinatal morbidity and mortality worldwide-we are convinced that the time has come to look beyond single clinical entities (e.g. pre-eclampsia, postpartum hemorrhage, obstetric sepsis) and to look for an integrated approach that will provide evidence-based personalized care to women wherever they encounter the health system. Accurate outcome prediction models are a powerful way to identify individuals at incrementally increased (and decreased) risks associated with a given condition. Integrating models with decision algorithms into mobile health (mHealth) applications could support community and first level facility healthcare providers to identify those women, fetuses, and newborns most at need of facility-based care, and to initiate lifesaving interventions in their communities prior to transportation. In our opinion, this offers the greatest opportunity to provide distributed individualized care at scale, and soon

    Evaluation of a novel device for the management of high blood pressure and shock in pregnancy in low-resource settings: study protocol for a stepped-wedge cluster-randomised controlled trial (CRADLE-3 trial).

    Get PDF
    BackgroundObstetric haemorrhage, sepsis and pregnancy hypertension account for more than 50% of maternal deaths worldwide. Early detection and effective management of these conditions relies on vital signs. The Microlife® CRADLE Vital Sign Alert (VSA) is an easy-to-use, accurate device that measures blood pressure and pulse. It incorporates a traffic-light early warning system that alerts all levels of healthcare provider to the need for escalation of care in women with obstetric haemorrhage, sepsis or pregnancy hypertension, thereby aiding early recognition of haemodynamic instability and preventing maternal mortality and morbidity. The aim of the trial was to determine whether implementation of the CRADLE intervention (the Microlife® CRADLE VSA device and CRADLE training package) into routine maternity care in place of existing equipment will reduce a composite outcome of maternal mortality and morbidity in low- and middle-income country populations.MethodsThe CRADLE-3 trial was a stepped-wedge cluster-randomised controlled trial of the CRADLE intervention compared to routine maternity care. Each cluster crossed from routine maternity care to the intervention at 2-monthly intervals over the course of 20 months (April 2016 to November 2017). All women identified as pregnant or within 6 weeks postpartum, presenting for maternity care in cluster catchment areas were eligible to participate. Primary outcome data (composite of maternal death, eclampsia and emergency hysterectomy per 10,000 deliveries) were collected at 10 clusters (Gokak, Belgaum, India; Harare, Zimbabwe; Ndola, Zambia; Lusaka, Zambia; Free Town, Sierra Leone; Mbale, Uganda; Kampala, Uganda; Cap Haitien, Haiti; South West, Malawi; Addis Ababa, Ethiopia). This trial was informed by the Medical Research Council guidance for complex interventions. A process evaluation was undertaken to evaluate implementation in each site and a cost-effectiveness evaluation will be undertaken.DiscussionAll aspects of this protocol have been evaluated in a feasibility study, with subsequent optimisation of the intervention. This trial will demonstrate the potential impact of the CRADLE intervention on reducing maternal mortality and morbidity in low-resource settings. It is anticipated that the relatively low cost of the intervention and ease of integration into existing health systems will be of significant interest to local, national and international health policy-makers.Trial registrationISCRTN41244132. Registered on 2 February 2016. Prospective protocol modifications have been recorded and were communicated to the Ethics Committees and Trials Committees. The adapted Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) Checklist and the SPIRIT Checklist are attached as Additional file 1

    Exploring the effect of implementation and context on a stepped-wedge randomised controlled trial of a vital sign triage device in routine maternity care in low-resource settings

    Get PDF
    © 2019 The Author(s). Background: Interventions aimed at reducing maternal mortality are increasingly complex. Understanding how complex interventions are delivered, to whom, and how they work is key in ensuring their rapid scale-up. We delivered a vital signs triage intervention into routine maternity care in eight low- and middle-income countries with the aim of reducing a composite outcome of morbidity and mortality. This was a pragmatic, hybrid effectiveness-implementation stepped-wedge randomised controlled trial. In this study, we present the results of the mixed-methods process evaluation. The aim was to describe implementation and local context and integrate results to determine whether differences in the effect of the intervention across sites could be explained. Methods: The duration and content of implementation, uptake of the intervention and its impact on clinical management were recorded. These were integrated with interviews (n = 36) and focus groups (n = 19) at 3 months and 6-9 months after implementation. In order to determine the effect of implementation on effectiveness, measures were ranked and averaged across implementation domains to create a composite implementation strength score and then correlated with the primary outcome. Results: Overall, 61.1% (n = 2747) of health care providers were trained in the intervention (range 16.5% to 89.2%) over a mean of 10.8 days. Uptake and acceptability of the intervention was good. All clusters demonstrated improved availability of vital signs equipment. There was an increase in the proportion of women having their blood pressure measured in pregnancy following the intervention (79.2% vs. 97.6%; OR 1.30 (1.29-1.31)) and no significant change in referral rates (3.7% vs. 4.4% OR 0.89; (0.39-2.05)). Availability of resources and acceptable, effective referral systems influenced health care provider interaction with the intervention. There was no correlation between process measures within or between domains, or between the composite score and the primary outcome. Conclusions: This process evaluation has successfully described the quantity and quality of implementation. Variation in implementation and context did not explain differences in the effectiveness of the intervention on maternal mortality and morbidity. We suggest future trials should prioritise in-depth evaluation of local context and clinical pathways. Trial registration: Trial registration: ISRCTN41244132. Registered on 2 Feb 2016
    • …
    corecore