253 research outputs found
Lensfree super-resolution holographic microscopy using wetting films on a chip.
We investigate the use of wetting films to significantly improve the imaging performance of lensfree pixel super-resolution on-chip microscopy, achieving < 1 µm spatial resolution over a large imaging area of ~24 mm(2). Formation of an ultra-thin wetting film over the specimen effectively creates a micro-lens effect over each object, which significantly improves the signal-to-noise-ratio and therefore the resolution of our lensfree images. We validate the performance of this approach through lensfree on-chip imaging of various objects having fine morphological features (with dimensions of e.g., ≤0.5 µm) such as Escherichia coli (E. coli), human sperm, Giardia lamblia trophozoites, polystyrene micro beads as well as red blood cells. These results are especially important for the development of highly sensitive field-portable microscopic analysis tools for resource limited settings
Recommended from our members
Lensfree computational microscopy tools for cell and tissue imaging at the point-of-care and in low-resource settings.
The recent revolution in digital technologies and information processing methods present important opportunities to transform the way optical imaging is performed, particularly toward improving the throughput of microscopes while at the same time reducing their relative cost and complexity. Lensfree computational microscopy is rapidly emerging toward this end, and by discarding lenses and other bulky optical components of conventional imaging systems, and relying on digital computation instead, it can achieve both reflection and transmission mode microscopy over a large field-of-view within compact, cost-effective and mechanically robust architectures. Such high throughput and miniaturized imaging devices can provide a complementary toolset for telemedicine applications and point-of-care diagnostics by facilitating complex and critical tasks such as cytometry and microscopic analysis of e.g., blood smears, Pap tests and tissue samples. In this article, the basics of these lensfree microscopy modalities will be reviewed, and their clinically relevant applications will be discussed
Automated single-cell motility analysis on a chip using lensfree microscopy.
Quantitative cell motility studies are necessary for understanding biophysical processes, developing models for cell locomotion and for drug discovery. Such studies are typically performed by controlling environmental conditions around a lens-based microscope, requiring costly instruments while still remaining limited in field-of-view. Here we present a compact cell monitoring platform utilizing a wide-field (24 mm(2)) lensless holographic microscope that enables automated single-cell tracking of large populations that is compatible with a standard laboratory incubator. We used this platform to track NIH 3T3 cells on polyacrylamide gels over 20 hrs. We report that, over an order of magnitude of stiffness values, collagen IV surfaces lead to enhanced motility compared to fibronectin, in agreement with biological uses of these structural proteins. The increased throughput associated with lensfree on-chip imaging enables higher statistical significance in observed cell behavior and may facilitate rapid screening of drugs and genes that affect cell motility
The ePetri dish, an on-chip cell imaging platform based on subpixel perspective sweeping microscopy (SPSM)
We report a chip-scale lensless wide-field-of-view microscopy imaging technique, subpixel perspective sweeping microscopy, which can render microscopy images of growing or confluent cell cultures autonomously. We demonstrate that this technology can be used to build smart Petri dish platforms, termed ePetri, for cell culture experiments. This technique leverages the recent broad and cheap availability of high performance image sensor chips to provide a low-cost and automated microscopy solution. Unlike the two major classes of lensless microscopy methods, optofluidic microscopy and digital in-line holography microscopy, this new approach is fully capable of working with cell cultures or any samples in which cells may be contiguously connected. With our prototype, we demonstrate the ability to image samples of area 6 mm × 4 mm at 660-nm resolution. As a further demonstration, we showed that the method can be applied to image color stained cell culture sample and to image and track cell culture growth directly within an incubator. Finally, we showed that this method can track embryonic stem cell differentiations over the entire sensor surface. Smart Petri dish based on this technology can significantly streamline and improve cell culture experiments by cutting down on human labor and contamination risks
Le juge administratif dans l'analyse juridique des politiques publiques
Aquesta ponència forma part del Workshop internacional de doctorands organitzat pel Programa de Doctorat en Dret de la UAB i la Facultat de Dret de la UAB, amb el suport de l'École Européenne de Droit de l'Université Toulouse Capitol
High speed phase retrieval of in-line holograms by the assistance of corresponding off-axis holograms
A step towards mobile arsenic measurement for surface waters.
Surface modified quantum dots (QDs) are studied using a bio-inspired cysteine rich ligand (glutathione, GSH) and their quenching response and selectivity to arsenic examined. As predicted from As(3+) binding with highly crosslinked phytochelatin-(PCn)-like molecules, better arsenic selectivity is obtained for a thicker more 3-dimensional GSH surface layer, with exposed sulfhydryl groups. A detection limit of at least 10 μM can be achieved using CdSe/ZnS core-shell QDs capped with this GSH structure. The system is also demonstrated using a mobile phone camera to record the measurement, producing a detection limit of 5 μM. However, copper remains the main interferent of concern. Water-soluble CdTe QDs show little sensitivity to As(3+) even with a GSH surface, but they remain sensitive to Cu(2+), allowing a copper baseline to be established from the CdTe measurement. Despite anticipating that spectrally non overlapping fluorescence would be required from the two types of QDs to achieve this, a method is demonstrated using RGB channels from a mobile phone and processing the raw data for CdTe QDs, with an emission wavelength of 600 nm, and CdSe/ZnS QDs, with emission maximum of 630 nm. It is shown that As(3+) measurement remains feasible at the WHO guideline value of 10 μg L(-1) up to a copper concentration of around 0.3 μM Cu(2+), which corresponds to the highest recorded level in a selection of large rivers world-wide.This is the author accepted manuscript. The final version is available via RSC at http://pubs.rsc.org/en/Content/ArticleLanding/2015/AN/c4an02368d#!divAbstract
Field-portable reflection and transmission microscopy based on lensless holography
We demonstrate a lensfree dual-mode holographic microscope that can image specimens in both transmission and reflection geometries using in-line transmission and off-axis reflection holography, respectively. This field-portable dual-mode holographic microscope has a weight of ~200 g with dimensions of 15 x 5.5 x 5cm, where a laser source is powered by two batteries. Based on digital in-line holography, our transmission microscope achieves a sub-pixel lateral resolution of ≤2 µm over a wide field-of-view (FOV) of ~24 mm2 due to its unit fringe magnification geometry. Despite its simplicity and ease of operation, in-line transmission geometry is not suitable to image dense or connected objects such as tissue slides since the reference beam gets distorted causing severe aberrations in reconstruction of such objects. To mitigate this challenge, on the same cost-effective and field-portable assembly we built a lensless reflection mode microscope based on digital off-axis holography where a beam-splitter is used to interfere a tilted reference wave with the reflected light from the object surface, creating an off-axis hologram of the specimens on a CMOS sensor-chip. As a result of the reduced space-bandwidth product of the off-axis geometry compared to its in-line counterpart, the imaging FOV of our reflection mode is reduced to ~9 mm2, while still achieving a similar sub-pixel resolution of ≤2 µm. We tested the performance of this compact dual-mode microscopy unit by imaging a US-air force resolution test target, various micro-particles as well as a histopathology slide corresponding to skin tissue. Due to its compact, cost-effective, and lightweight design, this dual-mode lensless holographic microscope might especially be useful for field-use or for conducting microscopic analysis in resource-poor settings
Inline holographic microscopy through fiber imaging bundles
Fiber imaging bundles are widely used as thin, passive image conduits for miniaturised and endoscopic microscopy, particularly for confocal fluorescence imaging. Holographic microscopy through fiber bundles is more challenging; phase conjugation approaches are complex and require extensive calibration. This article describes how simple inline holographic microscopy can be performed through an imaging bundle using a partially coherent illumination source from a multimode fiber. The sample is imaged in transmission, with the intensity hologram sampled by the bundle and transmitted to a remote camera. The hologram can then be numerically refocused for volumetric imaging, achieving a resolution of approximately 6 µm over a depth range of 1 mm. The scheme does not require any complex prior calibration and hence is insensitive to bending
Distributed Medical Image Analysis and Diagnosis through Crowd-Sourced Games: A Malaria Case Study
In this work we investigate whether the innate visual recognition and learning capabilities of untrained humans can be used in conducting reliable microscopic analysis of biomedical samples toward diagnosis. For this purpose, we designed entertaining digital games that are interfaced with artificial learning and processing back-ends to demonstrate that in the case of binary medical diagnostics decisions (e.g., infected vs. uninfected), with the use of crowd-sourced games it is possible to approach the accuracy of medical experts in making such diagnoses. Specifically, using non-expert gamers we report diagnosis of malaria infected red blood cells with an accuracy that is within 1.25% of the diagnostics decisions made by a trained medical professional
- …