2,428 research outputs found

    Tapered-amplified AR-coated laser diodes for Potassium and Rubidium atomic-physics experiments

    Full text link
    We present a system of room-temperature extended-cavity grating-diode lasers (ECDL) for production of light in the range 760-790nm. The extension of the tuning range towards the blue is permitted by the weak feedback in the cavity: the diodes are anti-reflection coated, and the grating has just 10% reflectance. The light is then amplified using semiconductor tapered amplifiers to give more than 400mW of power. The outputs are shown to be suitable for atomic physics experiments with potassium (767nm), rubidium (780nm) or both, of particular relevance to doubly-degenerate boson-fermion mixtures

    Impacto en los resultados de salud cardiovascular de la implantación del contrato de Dirección Clínica en atención primaria de Tarragona

    Get PDF
    ObjetivoLos objetivos del presente estudio son: a) determinar la mejora en la salud cardiovascular de una población tras la implantación del contrato de Dirección Clínica en los profesionales de los Equipos de Atención Primaria de Tarragona-Reus y Terres de l’Ebre (provincia de Tarragona), y b) identificar los factores predictivos que determinan una mejor salud cardiovascular tras la implantación del contrato de Dirección Clínica. La implantación del contrato de Dirección Clínica (basada en el liderazgo profesional, feedback de la información asistencial, control de los indicadores de riesgo cardiovascular basados en la evidencia científica concretadas en guías de práctica clínica) mejorará los resultados de salud cardiovascular de la población de referencia.DiseñoSe trata de un estudio antes-después y multicéntrico.EmplazamientoAtención primaria de salud.ParticipantesParticipan 30 centros de salud (totalidad de los centros de salud del ámbito de atención primaria del Institut Català de la Salut).Mediciones principalesCaracterísticas del centro. Variables de proceso: indicadores de buena práctica asistencial, cálculo del riesgo cardiovascular, aplicación de la guía de práctica clínica (hipertensión arterial, diabetes, dislipemia, tabaquismo y factores de riesgo cardiovascular), estándares de calidad de la prescripción farmacológica. Variables de resultados: cifras de riesgo cardiovascular, número de visitas en atención continuada, urgencias hospitalarias e ingresos por angina, infarto agudo de miocardio y accidente cerebrovascular, y cribados poblacionales de factores de riesgo.DiscusiónEste estudio es útil, ya que la dirección clinica pretende ser un motor para que los profesionales lideren la gestión asistencial y, mediante el control de indicadores y la «retroalimentación» de estos resultados a los profesionales, se mejore la calidad asistencial. Con este trabajo se pretende demostrar que una estrategia de gestión puede mejorar la salud cardiovascular de la población. La originalidad de este proyecto se basa en el desarrollo de una nueva herramienta de evaluación basada en una novedosa estrategia de gestión para medir resultados en salud cardiovascular.ObjectiveThe objectives of this study are: 1) to determine the improvement in the cardiovascular health of the population after the introduction of the clinical governance contract for primary care team professionals in Tarragona-Reus and the Terres de l’Ebre area (Tarragona province, Spain); 2) to identify the factors predictive of better cardiovascular health after the introduction of the clinical governance contract. The introduction of the clinical governance contract, which is based on professional leadership, feed-back of care information, and monitoring of indicators of cardiovascular risk based on scientific evidence and concretised in clinical practice guidelines, will improve the cardiovascular health results of the reference population. Improvements in indicators of procedure and result are specified in “Material and methods.”DesignThis is a before-and-after, multicentre study.SettingPrimary health care.ParticipantsTirty health centres (all the primary care Centres in the area).Main measurementsCharacteristics of the centre. Variables in procedures: indicators of good care practice, calculation of cardiovascular risk, application of clinical practice guidelines (hypertension, diabetes, lipaemia, tobacco and cardiovascular risk) and quality standards for drug prescription. Result variables: cardiovascular risk figures, number of ongoing care visits, hospital emergencies and admissions for angina, heart attack or stroke, and risk factor screenings of the population.DiscussionThis study is useful, in that clinical governance aims to be a dynamic device to bring professionals into the leadership of health care management and, through monitoring indicators and feeding the findings back to the professionals, to improve health care quality. The study aims to show that management strategy can improve the populatiońs cardiovascular health. The originality of the study lies in the development of a new tool of evaluation based on a novel management strategy for measuring cardiovascular health findings

    Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up

    Get PDF
    A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Moli\`ere radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.Comment: Paper published in Eur. Phys. J., includes 25 figures and 3 Table

    ECFA Detector R&D Panel, Review Report

    Full text link
    Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 103^{-3} at the ILC and 102^{-2} at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.Comment: 61 pages, 51 figure

    Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

    Get PDF
    Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.Comment: 25 pages, 32 figures, revised version following comments from referee

    Observation of two new Ξb\Xi_b^- baryon resonances

    Get PDF
    Two structures are observed close to the kinematic threshold in the Ξb0π\Xi_b^0 \pi^- mass spectrum in a sample of proton-proton collision data, corresponding to an integrated luminosity of 3.0 fb1^{-1} recorded by the LHCb experiment. In the quark model, two baryonic resonances with quark content bdsbds are expected in this mass region: the spin-parity JP=12+J^P = \frac{1}{2}^+ and JP=32+J^P=\frac{3}{2}^+ states, denoted Ξb\Xi_b^{\prime -} and Ξb\Xi_b^{*-}. Interpreting the structures as these resonances, we measure the mass differences and the width of the heavier state to be m(Ξb)m(Ξb0)m(π)=3.653±0.018±0.006m(\Xi_b^{\prime -}) - m(\Xi_b^0) - m(\pi^{-}) = 3.653 \pm 0.018 \pm 0.006 MeV/c2/c^2, m(Ξb)m(Ξb0)m(π)=23.96±0.12±0.06m(\Xi_b^{*-}) - m(\Xi_b^0) - m(\pi^{-}) = 23.96 \pm 0.12 \pm 0.06 MeV/c2/c^2, Γ(Ξb)=1.65±0.31±0.10\Gamma(\Xi_b^{*-}) = 1.65 \pm 0.31 \pm 0.10 MeV, where the first and second uncertainties are statistical and systematic, respectively. The width of the lighter state is consistent with zero, and we place an upper limit of Γ(Ξb)<0.08\Gamma(\Xi_b^{\prime -}) < 0.08 MeV at 95% confidence level. Relative production rates of these states are also reported.Comment: 17 pages, 2 figure

    Measurement of the Bs0J/ψηB_{s}^{0} \rightarrow J/\psi \eta lifetime

    Get PDF
    Using a data set corresponding to an integrated luminosity of 3fb13 fb^{-1}, collected by the LHCb experiment in pppp collisions at centre-of-mass energies of 7 and 8 TeV, the effective lifetime in the Bs0J/ψηB^0_s \rightarrow J/\psi \eta decay mode, τeff\tau_{\textrm{eff}}, is measured to be τeff=1.479±0.034 (stat)±0.011 (syst)\tau_{\textrm{eff}} = 1.479 \pm 0.034~\textrm{(stat)} \pm 0.011 ~\textrm{(syst)} ps. Assuming CPCP conservation, τeff\tau_{\textrm{eff}} corresponds to the lifetime of the light Bs0B_s^0 mass eigenstate. This is the first measurement of the effective lifetime in this decay mode.Comment: All figures and tables, along with any supplementary material and additional information, are available at https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-017.htm

    Measurement of the mass and lifetime of the Ωb\Omega_b^- baryon

    Get PDF
    A proton-proton collision data sample, corresponding to an integrated luminosity of 3 fb1^{-1} collected by LHCb at s=7\sqrt{s}=7 and 8 TeV, is used to reconstruct 63±963\pm9 ΩbΩc0π\Omega_b^-\to\Omega_c^0\pi^-, Ωc0pKKπ+\Omega_c^0\to pK^-K^-\pi^+ decays. Using the ΞbΞc0π\Xi_b^-\to\Xi_c^0\pi^-, Ξc0pKKπ+\Xi_c^0\to pK^-K^-\pi^+ decay mode for calibration, the lifetime ratio and absolute lifetime of the Ωb\Omega_b^- baryon are measured to be \begin{align*} \frac{\tau_{\Omega_b^-}}{\tau_{\Xi_b^-}} &= 1.11\pm0.16\pm0.03, \\ \tau_{\Omega_b^-} &= 1.78\pm0.26\pm0.05\pm0.06~{\rm ps}, \end{align*} where the uncertainties are statistical, systematic and from the calibration mode (for τΩb\tau_{\Omega_b^-} only). A measurement is also made of the mass difference, mΩbmΞbm_{\Omega_b^-}-m_{\Xi_b^-}, and the corresponding Ωb\Omega_b^- mass, which yields \begin{align*} m_{\Omega_b^-}-m_{\Xi_b^-} &= 247.4\pm3.2\pm0.5~{\rm MeV}/c^2, \\ m_{\Omega_b^-} &= 6045.1\pm3.2\pm 0.5\pm0.6~{\rm MeV}/c^2. \end{align*} These results are consistent with previous measurements.Comment: 11 pages, 5 figures, All figures and tables, along with any supplementary material and additional information, are available at https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-008.htm

    Observation of J/ψpJ/\psi p resonances consistent with pentaquark states in Λb0J/ψKp{\Lambda_b^0\to J/\psi K^-p} decays

    Get PDF
    Observations of exotic structures in the J/ψpJ/\psi p channel, that we refer to as pentaquark-charmonium states, in Λb0J/ψKp\Lambda_b^0\to J/\psi K^- p decays are presented. The data sample corresponds to an integrated luminosity of 3/fb acquired with the LHCb detector from 7 and 8 TeV pp collisions. An amplitude analysis is performed on the three-body final-state that reproduces the two-body mass and angular distributions. To obtain a satisfactory fit of the structures seen in the J/ψpJ/\psi p mass spectrum, it is necessary to include two Breit-Wigner amplitudes that each describe a resonant state. The significance of each of these resonances is more than 9 standard deviations. One has a mass of 4380±8±294380\pm 8\pm 29 MeV and a width of 205±18±86205\pm 18\pm 86 MeV, while the second is narrower, with a mass of 4449.8±1.7±2.54449.8\pm 1.7\pm 2.5 MeV and a width of 39±5±1939\pm 5\pm 19 MeV. The preferred JPJ^P assignments are of opposite parity, with one state having spin 3/2 and the other 5/2.Comment: 48 pages, 18 figures including the supplementary material, v2 after referee's comments, now 19 figure

    Observation of an Excited Bc+ State

    Get PDF
    Using pp collision data corresponding to an integrated luminosity of 8.5 fb-1 recorded by the LHCb experiment at center-of-mass energies of s=7, 8, and 13 TeV, the observation of an excited Bc+ state in the Bc+π+π- invariant-mass spectrum is reported. The observed peak has a mass of 6841.2±0.6(stat)±0.1(syst)±0.8(Bc+) MeV/c2, where the last uncertainty is due to the limited knowledge of the Bc+ mass. It is consistent with expectations of the Bc∗(2S31)+ state reconstructed without the low-energy photon from the Bc∗(1S31)+→Bc+γ decay following Bc∗(2S31)+→Bc∗(1S31)+π+π-. A second state is seen with a global (local) statistical significance of 2.2σ (3.2σ) and a mass of 6872.1±1.3(stat)±0.1(syst)±0.8(Bc+) MeV/c2, and is consistent with the Bc(2S10)+ state. These mass measurements are the most precise to date
    corecore