2,428 research outputs found
Tapered-amplified AR-coated laser diodes for Potassium and Rubidium atomic-physics experiments
We present a system of room-temperature extended-cavity grating-diode lasers
(ECDL) for production of light in the range 760-790nm. The extension of the
tuning range towards the blue is permitted by the weak feedback in the cavity:
the diodes are anti-reflection coated, and the grating has just 10%
reflectance. The light is then amplified using semiconductor tapered amplifiers
to give more than 400mW of power. The outputs are shown to be suitable for
atomic physics experiments with potassium (767nm), rubidium (780nm) or both, of
particular relevance to doubly-degenerate boson-fermion mixtures
Impacto en los resultados de salud cardiovascular de la implantación del contrato de Dirección Clínica en atención primaria de Tarragona
ObjetivoLos objetivos del presente estudio son: a) determinar la mejora en la salud cardiovascular de una población tras la implantación del contrato de Dirección Clínica en los profesionales de los Equipos de Atención Primaria de Tarragona-Reus y Terres de l’Ebre (provincia de Tarragona), y b) identificar los factores predictivos que determinan una mejor salud cardiovascular tras la implantación del contrato de Dirección Clínica. La implantación del contrato de Dirección Clínica (basada en el liderazgo profesional, feedback de la información asistencial, control de los indicadores de riesgo cardiovascular basados en la evidencia científica concretadas en guías de práctica clínica) mejorará los resultados de salud cardiovascular de la población de referencia.DiseñoSe trata de un estudio antes-después y multicéntrico.EmplazamientoAtención primaria de salud.ParticipantesParticipan 30 centros de salud (totalidad de los centros de salud del ámbito de atención primaria del Institut Català de la Salut).Mediciones principalesCaracterísticas del centro. Variables de proceso: indicadores de buena práctica asistencial, cálculo del riesgo cardiovascular, aplicación de la guía de práctica clínica (hipertensión arterial, diabetes, dislipemia, tabaquismo y factores de riesgo cardiovascular), estándares de calidad de la prescripción farmacológica. Variables de resultados: cifras de riesgo cardiovascular, número de visitas en atención continuada, urgencias hospitalarias e ingresos por angina, infarto agudo de miocardio y accidente cerebrovascular, y cribados poblacionales de factores de riesgo.DiscusiónEste estudio es útil, ya que la dirección clinica pretende ser un motor para que los profesionales lideren la gestión asistencial y, mediante el control de indicadores y la «retroalimentación» de estos resultados a los profesionales, se mejore la calidad asistencial. Con este trabajo se pretende demostrar que una estrategia de gestión puede mejorar la salud cardiovascular de la población. La originalidad de este proyecto se basa en el desarrollo de una nueva herramienta de evaluación basada en una novedosa estrategia de gestión para medir resultados en salud cardiovascular.ObjectiveThe objectives of this study are: 1) to determine the improvement in the cardiovascular health of the population after the introduction of the clinical governance contract for primary care team professionals in Tarragona-Reus and the Terres de l’Ebre area (Tarragona province, Spain); 2) to identify the factors predictive of better cardiovascular health after the introduction of the clinical governance contract. The introduction of the clinical governance contract, which is based on professional leadership, feed-back of care information, and monitoring of indicators of cardiovascular risk based on scientific evidence and concretised in clinical practice guidelines, will improve the cardiovascular health results of the reference population. Improvements in indicators of procedure and result are specified in “Material and methods.”DesignThis is a before-and-after, multicentre study.SettingPrimary health care.ParticipantsTirty health centres (all the primary care Centres in the area).Main measurementsCharacteristics of the centre. Variables in procedures: indicators of good care practice, calculation of cardiovascular risk, application of clinical practice guidelines (hypertension, diabetes, lipaemia, tobacco and cardiovascular risk) and quality standards for drug prescription. Result variables: cardiovascular risk figures, number of ongoing care visits, hospital emergencies and admissions for angina, heart attack or stroke, and risk factor screenings of the population.DiscussionThis study is useful, in that clinical governance aims to be a dynamic device to bring professionals into the leadership of health care management and, through monitoring indicators and feeding the findings back to the professionals, to improve health care quality. The study aims to show that management strategy can improve the populatiońs cardiovascular health. The originality of the study lies in the development of a new tool of evaluation based on a novel management strategy for measuring cardiovascular health findings
Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up
A prototype of a luminometer, designed for a future e+e- collider detector,
and consisting at present of a four-plane module, was tested in the CERN PS
accelerator T9 beam. The objective of this beam test was to demonstrate a
multi-plane tungsten/silicon operation, to study the development of the
electromagnetic shower and to compare it with MC simulations. The Moli\`ere
radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using
a parametrization of the shower shape. Very good agreement was found between
data and a detailed Geant4 simulation.Comment: Paper published in Eur. Phys. J., includes 25 figures and 3 Table
ECFA Detector R&D Panel, Review Report
Two special calorimeters are foreseen for the instrumentation of the very
forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to
measure the rate of low angle Bhabha scattering events with a precision better
than 10 at the ILC and 10 at CLIC, and a low polar-angle
calorimeter (BeamCal). The latter will be hit by a large amount of
beamstrahlung remnants. The intensity and the spatial shape of these
depositions will provide a fast luminosity estimate, as well as determination
of beam parameters. The sensors of this calorimeter must be radiation-hard.
Both devices will improve the e.m. hermeticity of the detector in the search
for new particles. Finely segmented and very compact electromagnetic
calorimeters will match these requirements. Due to the high occupancy, fast
front-end electronics will be needed. Monte Carlo studies were performed to
investigate the impact of beam-beam interactions and physics background
processes on the luminosity measurement, and of beamstrahlung on the
performance of BeamCal, as well as to optimise the design of both calorimeters.
Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and
prototypes are available. Prototypes of sensor planes fully assembled with
readout electronics have been studied in electron beams.Comment: 61 pages, 51 figure
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Detector-plane prototypes of the very forward calorimetry of a future
detector at an e+e- collider have been built and their performance was measured
in an electron beam. The detector plane comprises silicon or GaAs pad sensors,
dedicated front-end and ADC ASICs, and an FPGA for data concentration.
Measurements of the signal-to-noise ratio and the response as a function of the
position of the sensor are presented. A deconvolution method is successfully
applied, and a comparison of the measured shower shape as a function of the
absorber depth with a Monte-Carlo simulation is given.Comment: 25 pages, 32 figures, revised version following comments from
referee
Observation of two new baryon resonances
Two structures are observed close to the kinematic threshold in the mass spectrum in a sample of proton-proton collision data, corresponding
to an integrated luminosity of 3.0 fb recorded by the LHCb experiment.
In the quark model, two baryonic resonances with quark content are
expected in this mass region: the spin-parity and
states, denoted and .
Interpreting the structures as these resonances, we measure the mass
differences and the width of the heavier state to be
MeV,
MeV,
MeV, where the first and second
uncertainties are statistical and systematic, respectively. The width of the
lighter state is consistent with zero, and we place an upper limit of
MeV at 95% confidence level. Relative
production rates of these states are also reported.Comment: 17 pages, 2 figure
Measurement of the lifetime
Using a data set corresponding to an integrated luminosity of ,
collected by the LHCb experiment in collisions at centre-of-mass energies
of 7 and 8 TeV, the effective lifetime in the
decay mode, , is measured to be ps. Assuming
conservation, corresponds to the lifetime of the light
mass eigenstate. This is the first measurement of the effective
lifetime in this decay mode.Comment: All figures and tables, along with any supplementary material and
additional information, are available at
https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-017.htm
Measurement of the mass and lifetime of the baryon
A proton-proton collision data sample, corresponding to an integrated
luminosity of 3 fb collected by LHCb at and 8 TeV, is used
to reconstruct , decays. Using the , decay mode for calibration, the lifetime ratio and absolute
lifetime of the baryon are measured to be \begin{align*}
\frac{\tau_{\Omega_b^-}}{\tau_{\Xi_b^-}} &= 1.11\pm0.16\pm0.03, \\
\tau_{\Omega_b^-} &= 1.78\pm0.26\pm0.05\pm0.06~{\rm ps}, \end{align*} where the
uncertainties are statistical, systematic and from the calibration mode (for
only). A measurement is also made of the mass difference,
, and the corresponding mass, which
yields \begin{align*} m_{\Omega_b^-}-m_{\Xi_b^-} &= 247.4\pm3.2\pm0.5~{\rm
MeV}/c^2, \\ m_{\Omega_b^-} &= 6045.1\pm3.2\pm 0.5\pm0.6~{\rm MeV}/c^2.
\end{align*} These results are consistent with previous measurements.Comment: 11 pages, 5 figures, All figures and tables, along with any
supplementary material and additional information, are available at
https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-008.htm
Observation of resonances consistent with pentaquark states in decays
Observations of exotic structures in the channel, that we refer to
as pentaquark-charmonium states, in decays are
presented. The data sample corresponds to an integrated luminosity of 3/fb
acquired with the LHCb detector from 7 and 8 TeV pp collisions. An amplitude
analysis is performed on the three-body final-state that reproduces the
two-body mass and angular distributions. To obtain a satisfactory fit of the
structures seen in the mass spectrum, it is necessary to include two
Breit-Wigner amplitudes that each describe a resonant state. The significance
of each of these resonances is more than 9 standard deviations. One has a mass
of MeV and a width of MeV, while the second
is narrower, with a mass of MeV and a width of MeV. The preferred assignments are of opposite parity, with one
state having spin 3/2 and the other 5/2.Comment: 48 pages, 18 figures including the supplementary material, v2 after
referee's comments, now 19 figure
Observation of an Excited Bc+ State
Using pp collision data corresponding to an integrated luminosity of 8.5 fb-1 recorded by the LHCb experiment at center-of-mass energies of s=7, 8, and 13 TeV, the observation of an excited Bc+ state in the Bc+π+π- invariant-mass spectrum is reported. The observed peak has a mass of 6841.2±0.6(stat)±0.1(syst)±0.8(Bc+) MeV/c2, where the last uncertainty is due to the limited knowledge of the Bc+ mass. It is consistent with expectations of the Bc∗(2S31)+ state reconstructed without the low-energy photon from the Bc∗(1S31)+→Bc+γ decay following Bc∗(2S31)+→Bc∗(1S31)+π+π-. A second state is seen with a global (local) statistical significance of 2.2σ (3.2σ) and a mass of 6872.1±1.3(stat)±0.1(syst)±0.8(Bc+) MeV/c2, and is consistent with the Bc(2S10)+ state. These mass measurements are the most precise to date
- …