137 research outputs found

    House Bill 4581: Annual Flu Vaccinations

    Get PDF

    Graduate Recital: Emma McDermitt-Wise, soprano

    Get PDF

    Graduate Recital: Emma McDermitt-Wise, soprano

    Get PDF

    Distinct Self-Renewal and Differentiation Phases in the Niche of Infrequently Dividing Hair Follicle Stem Cells

    Get PDF
    SummaryIn homeostasis of adult vertebrate tissues, stem cells are thought to self-renew by infrequent and asymmetric divisions that generate another stem cell daughter and a progenitor daughter cell committed to differentiate. This model is based largely on in vivo invertebrate or in vitro mammal studies. Here, we examine the dynamic behavior of adult hair follicle stem cells in their normal setting by employing mice with repressible H2B-GFP expression to track cell divisions and Cre-inducible mice to perform long-term single-cell lineage tracing. We provide direct evidence for the infrequent stem cell division model in intact tissue. Moreover, we find that differentiation of progenitor cells occurs at different times and tissue locations than self-renewal of stem cells. Distinct fates of differentiation or self-renewal are assigned to individual cells in a temporal-spatial manner. We propose that large clusters of tissue stem cells behave as populations whose maintenance involves unidirectional daughter-cell-fate decisions

    Application of Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

    Get PDF
    Monitoring carbon dioxide (CO2) concentration within a spacecraft or spacesuit is critically important to ensuring the safety of the crew. Carbon dioxide uniquely absorbs light at wavelengths of 3.95 micrometers and 4.26 micrometers. As a result, non-dispersive infrared (NDIR) spectroscopy can be employed as a reliable and inexpensive method for the quantification of CO2 within the atmosphere. A multitude of commercial-off-the-shelf (COTS) NDIR sensors exist for CO2 quantification. The COTS sensors provide reasonable accuracy so long as the measurements are attained under conditions close to the calibration conditions of the sensor (typically 21.1 C and 1 atm). However, as pressure deviates from atmospheric to the pressures associated with a spacecraft (8.0-10.2 PSIA) or spacesuit (4.1-8.0 PSIA), the error in the measurement grows increasingly large. In addition to pressure and temperature dependencies, the infrared transmissivity through a volume of gas also depends on the composition of the gas. As the composition is not known a priori, accurate sub-ambient detection must rely on iterative sensor compensation techniques. This manuscript describes the development of recursive compensation algorithms for sub-ambient detection of CO2 with COTS NDIR sensors. In addition, the basis of the exponential loss in accuracy is developed theoretically considering thermal, Doppler, and Lorentz broadening effects which arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. As a result, this manuscript provides an approach to employing COTS sensors at sub-ambient conditions and may also lend insight into designing future NDIR sensors for aerospace application

    Impact of changes in barometric pressure on landfill methane emission

    Get PDF
    Citation: Xu, Liukang, Xiaomao Lin, Jim Amen, Karla Welding, and Dayle McDermitt. “Impact of Changes in Barometric Pressure on Landfill Methane Emission.” Global Biogeochemical Cycles 28, no. 7 (2014): 679–95. https://doi.org/10.1002/2013GB004571.Landfill methane emissions were measured continuously using the eddy covariance method from June to December 2010. The study site was located at the Bluff Road Landfill in Lincoln, Nebraska, USA. Our results show that landfill methane emissions strongly depended on changes in barometric pressure; rising barometric pressure suppressed the emission, while falling barometric pressure enhanced the emission, a phenomenon called barometric pumping. There was up to a 35-fold variation in day-to-day methane emissions due to changes in barometric pressure. Wavelet coherence analysis revealed a strong spectral coherency between variations of barometric pressure and methane emission at periodicities ranging from 1 day to 8 days. Power spectrum and ogive analysis showed that at least 10 days of continuous measurements was needed in order to capture 90% of the total variance in the methane emission time series at our landfill site. From our results, it is clear that point-in-time measurements taken at monthly or longer time intervals using techniques such as the trace plume method, the mass balance method, or the closed-chamber method will be subject to large variations in measured emission rates because of the barometric pumping phenomenon. Estimates of long-term integrated methane emissions from landfills based on such measurements could yield uncertainties, ranging from 28.8% underestimation to 32.3% overestimation. Our results demonstrate a need for continuous measurements to quantify annual total landfill emissions. This conclusion may apply to the study of methane emissions from wetlands, peatlands, lakes, and other environmental contexts where emissions are from porous media or ebullition. Other implications from the present study for hazard gas monitoring programs are also discussed

    Parental awareness of adolescent substance use

    Get PDF
    Sherpa Romeo green journal. Permission to archive accepted author manuscriptParental awareness of adolescent substance use was investigated in a high school sample of 985 adolescents and their parents. Only 39% of parents were aware their adolescent used tobacco, only 34% were aware of alcohol use, and only 11% were aware of illicit drug use. There were no variables that differentiated aware from unaware parents for all substances. Greater parental awareness of alcohol and tobacco use occurred with older adolescents. High adolescent ratings of family communication combined with low parental ratings of family communication were also associated with greater parental awareness of alcohol and tobacco use. Better school grades predicted greater awareness of alcohol and illicit drug use. Single parents and blended families were more aware of tobacco and illicit drug use.Ye

    Methane fluxes from a small boreal lake measured with the eddy covariance method

    Get PDF
    Fluxes of methane, CH4, were measured with the eddy covariance (EC) method at a small boreal lake in Sweden. The mean CH4 flux during the growing season of 2013 was 20.1 nmol m(-2) s(-1) and the median flux was 16 nmol m(-2) s(-1) (corresponding to 1.7 mmol m(-2) d(-1) and 1.4 mmol m(-2) d(-1)). Monthly mean values of CH4 flux measured with the EC method were compared with fluxes measured with floating chambers (FC) and were in average 62% higher over the whole study period. The difference was greatest in April partly because EC, but not FC, accounted for fluxes due to ice melt and a subsequent lake mixing event. A footprint analysis revealed that the EC footprint included primarily the shallow side of the lake with a major inlet. This inlet harbors emergent macrophytes that can mediate high CH4 fluxes. The difference between measured EC and FC fluxes can hence be explained by different footprint areas, where the EC system sees the part of the lake presumably releasing higher amounts of CH4. EC also provides more frequent measurements than FC and hence more likely captures ebullition events. This study shows that small lakes have CH4 fluxes that are highly variable in time and space. Based on our findings we suggest to measure CH4 fluxes from lakes as continuously as possible and to aim for covering as much of the lakes surface as possible, independently of the selected measuring technique.Funding Agencies|Swedish Research Council FORMAS, project Color of Water (CoW); Swedish Research Council FORMAS, project Landscape Greenhouse Gas Exchange (LAGGE)</p

    Standardisation of eddy-covariance flux measurements of methane and nitrous oxide

    Get PDF
    Commercially available fast-response analysers for methane (CH4) and nitrous oxide (N2O) have recently become more sensitive, more robust and easier to operate. This has made their application for long-term flux measurements with the eddycovariance method more feasible. Unlike for carbon dioxide (CO2) and water vapour (H2O), there have so far been no guidelines on how to optimise and standardise the measurements. This paper reviews the state-of-the-art of the various steps of the measurements and discusses aspects such as instrument selection, setup and maintenance, data processing as well as the additional measurements needed to aid interpretation and gap-filling. It presents the methodological protocol for eddy covariance measurements of CH4 and N2O fluxes as agreed for the ecosystem station network of the pan-European Research Infrastructure Integrated Carbon Observation System and provides a first international standard that is suggested to be adopted more widely. Fluxes can be episodic and the processes controlling the fluxes are complex, preventing simple mechanistic gap-filling strategies. Fluxes are often near or below the detection limit, requiring additional care during data processing. The protocol sets out the best practice for these conditions to avoid biasing the results and long-term budgets. It summarises the current approach to gap-filling.Peer reviewe

    In situ CO2 and O2 measurements on a profiling float

    Get PDF
    In recent years, profiling floats, which form the basis of the successful international Argo observatory, are also being considered as platforms for marine biogeochemical research. This study showcases the utility of floats as a novel tool for combined gas measurements of CO2 partial pressure (pCO2) and O2. These float prototypes were equipped with a small-sized and submersible pCO2 sensor and an optode O2 sensor for high resolution measurements in the surface ocean layer. Four consecutive deployments were carried out during Nov. 2010 and June 2011 near the Cape Verde Ocean Observatory (CVOO) in the eastern tropical North Atlantic. The profiling float performed upcasts every 31 h while measuring pCO2, O2, salinity, temperature and hydrostatic pressure in the upper 200 m of the water column. In order to maintain accuracy, regular pCO2 sensor zeroings at depth and surface, as well as optode measurements in air, were performed for each profile. Through the application of data processing procedures (e.g., time-lag correction) accuracies of float-borne pCO2 measurements were greatly improved (10 – 15 μatm for water column and 5 μatm for surface measurements). O2 measurements yielded an accuracy of 2 μmol kg−1. First results of this pilot study show the possibility of using profiling floats as a platform for detailed and unattended observations of the marine carbon and oxygen cycle dynamics
    corecore