3,190 research outputs found

    Comparing acoustic and radar deterrence methods as mitigation measures to reduce human-bat impacts and conservation conflicts

    Get PDF
    Where humans and wildlife co-exist, mitigation is often needed to alleviate potential conflicts and impacts. Deterrence methods can be used to reduce impacts of human structures or activities on wildlife, or to resolve conservation conflicts in areas where animals may be regarded as a nuisance or pose a health hazard. Here we test two methods (acoustic and radar) that have shown potential for deterring bats away from areas where they forage and/or roost. Using both infrared video and acoustic methods for counting bat passes, we show that ultrasonic speakers were effective as bat deterrents at foraging sites, but radar was not. Ultrasonic deterrents decreased overall bat activity (filmed on infrared cameras) by ~80% when deployed alone and in combination with radar. However, radar alone had no effect on bat activity when video or acoustic data were analysed using generalised linear mixed effect models. Feeding buzzes of all species were reduced by 79% and 69% in the ultrasound only treatment when compared to the control and radar treatments, but only the ultrasound treatment was significant in post-hoc tests. Species responded differently to the ultrasound treatments and we recorded a deterrent effect on both Pipistrellus pipistrellus (~40-80% reduction in activity) and P. pygmaeus (~30-60% reduction), but not on Myotis species. However, only the ultrasound and radar treatment was significant (when compared to control and radar) in post-hoc tests for P. pipistrellus. Deterrent treatment was marginally non-significant for P. pygmaeus, but the ultrasound only treatment was significant when compared to radar in post-hoc tests. We therefore suggest that acoustic, but not radar methods are explored further as deterrents for bats. The use of acoustic deterrence should always be assessed on a case-by-case basis, with a focus on bat conservation

    Visualisation of Bluetongue Virus in the Salivary Apparatus of Culicoides Biting Midges Highlights the Accessory Glands as a Primary Arboviral Infection Site.

    Get PDF
    BACKGROUND Arthropods transmit a wide range of pathogens of importance for the global health of humans, animals, and plants. One group of these arthropod vectors, Culicoides biting midges (Diptera: Ceratopogonidae), is the biological vector of several human and animal pathogens, including economically important livestock viruses like bluetongue virus (BTV). Like other arthropod-borne viruses (arboviruses), Culicoides-borne viruses must reach and replicate in the salivary apparatus, from where they can be transmitted to susceptible hosts through the saliva during subsequent blood feeding. Despite the importance of the salivary gland apparatus for pathogen transmission to susceptible animals from the bite of infected Culicoides, these structures have received relatively little attention, perhaps due to the small size and fragility of these vectors. RESULTS In this study, we developed techniques to visualize the infection of the salivary glands and other soft tissues with BTV, in some of the smallest known arbovirus vectors, Culicoides biting midges, using three-dimensional immunofluorescence confocal microscopy. We showed BTV infection of specific structures of the salivary gland apparatus of female Culicoides vectors following oral virus uptake, related visualisation of viral infection in the salivary apparatus to high viral RNA copies in the body, and demonstrated for the first time, that the accessory glands are a primary site for BTV replication within the salivary apparatus. CONCLUSIONS Our work has revealed a novel site of virus-vector interactions, and a novel role of the accessory glands of Culicoides in arbovirus amplification and transmission. Our approach would also be applicable to a wide range of arbovirus vector groups including sand flies (Diptera: Psychodidae), as well as provide a powerful tool to investigate arbovirus infection and dissemination, particularly where there are practical challenges in the visualization of small size and delicate tissues of arthropods

    Isolated Pd Sites as Selective Catalysts for Electrochemical and Direct Hydrogen Peroxide Synthesis

    Get PDF
    Palladium nanoparticles have been studied extensively as catalysts for the direct synthesis of hydrogen peroxide, where selectivity remains a key challenge. Alloying Pd with other metals and the use of acid and halide promoters are commonly used to increase H2O2 selectivity, however; the sites that can selectively produce H2O2 have not been identified and the role of these additives remains unclear. Here, we report the synthesis of atomically dispersed Pd/C as a model catalyst for H2O2 production without the presence of extended Pd surfaces. We show that these isolated cationic Pd sites can form H2O2 with significantly higher selectivity than metallic Pd nanoparticles in both the reaction of H2 and O2 and the electrochemical oxygen reduction reaction (ORR). This demonstrates that catalysts containing high populations of isolated Pd sites are selective catalysts for this two-electron reduction reaction and that the performance of materials in the direct synthesis reaction and ORR have many similarities

    BLAST05: Power Spectra of Bright Galactic Cirrus at Submillimeter Wavelengths

    Get PDF
    We report multi-wavelength power spectra of diffuse Galactic dust emission from BLAST observations at 250, 350, and 500 microns in Galactic Plane fields in Cygnus X and Aquila. These submillimeter power spectra statistically quantify the self-similar structure observable over a broad range of scales and can be used to assess the cirrus noise which limits the detection of faint point sources. The advent of submillimeter surveys with the Herschel Space Observatory makes the wavelength dependence a matter of interest. We show that the observed relative amplitudes of the power spectra can be related through a spectral energy distribution (SED). Fitting a simple modified black body to this SED, we find the dust temperature in Cygnus X to be 19.9 +/- 1.3 K and in the Aquila region 16.9 +/- 0.7 K. Our empirical estimates provide important new insight into the substantial cirrus noise that will be encountered in forthcoming observations.Comment: Submitted to the Astrophysical Journal. Maps and other data are available at http://blastexperiment.info

    QRS complex and T wave planarity for the efficacy prediction of automatic implantable defibrillators.

    Get PDF
    OBJECTIVE To test the hypothesis that in recipients of primary prophylactic implantable cardioverter-defibrillators (ICDs), the non-planarity of ECG vector loops predicts (a) deaths despite ICD protection and (b) appropriate ICD shocks. METHODS Digital pre-implant ECGs were collected in 1948 ICD recipients: 21.4% females, median age 65 years, 61.5% ischaemic heart disease (IHD). QRS and T wave three-dimensional loops were constructed using singular value decomposition that allowed to measure the vector loop planarity. The non-planarity, that is, the twist of the three-dimensional loops out of a single plane, was related to all-cause mortality (n=294; 15.3% females; 68.7% IHD) and appropriate ICD shocks (n=162; 10.5% females; 87.7% IHD) during 5-year follow-up after device implantation. Using multivariable Cox regression, the predictive power of QRS and T wave non-planarity was compared with that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval and T-peak to T-end interval. RESULTS QRS non-planarity was significantly (p<0.001) associated with follow-up deaths despite ICD protection with HR of 1.339 (95% CI 1.165 to 1.540) but was only univariably associated with appropriate ICD shocks. Non-planarity of the T wave loop was the only ECG-derived index significantly (p<0.001) associated with appropriate ICD shocks with multivariable Cox regression HR of 1.364 (1.180 to 1.576) but was not associated with follow-up mortality. CONCLUSIONS The analysed data suggest that QRS and T wave non-planarity might offer distinction between patients who are at greater risk of death despite ICD protection and those who are likely to use the defibrillator protection

    Paternal age explains a major portion of de novo germline mutation rate variability in healthy individuals

    Get PDF
    De novo mutations (DNM) are an important source of rare variants and are increasingly being linked to the development of many diseases. Recently, the paternal age effect has been the focus of a number of studies that attempt to explain the observation that increasing paternal age increases the risk for a number of diseases. Using disease-free familial quartets we show that there is a strong positive correlation between paternal age and germline DNM in healthy subjects. We also observed that germline CNVs do not follow the same trend, suggesting a different mechanism. Finally, we observed that DNM were not evenly distributed across the genome, which adds support to the existence of DNM hotspots

    Global Characterisation of Coagulopathy in Isolated Traumatic Brain Injury (iTBI): A CENTER-TBI Analysis

    Get PDF
    Background - Trauma-induced coagulopathy in patients with traumatic brain injury (TBI) is associated with high rates of complications, unfavourable outcomes and mortality. The mechanism of the development of TBI-associated coagulopathy is poorly understood. Methods - This analysis, embedded in the prospective, multi-centred, observational Collaborative European NeuroTrauma Effectiveness Research in Traumatic Brain Injury (CENTER-TBI) study, aimed to characterise the coagulopathy of TBI. Emphasis was placed on the acute phase following TBI, primary on subgroups of patients with abnormal coagulation profile within 4 h of admission, and the impact of pre-injury anticoagulant and/or antiplatelet therapy. In order to minimise confounding factors, patients with isolated TBI (iTBI) (n = 598) were selected for this analysis. Results - Haemostatic disorders were observed in approximately 20% of iTBI patients. In a subgroup analysis, patients with pre-injury anticoagulant and/or antiplatelet therapy had a twice exacerbated coagulation profile as likely as those without premedication. This was in turn associated with increased rates of mortality and unfavourable outcome post-injury. A multivariate analysis of iTBI patients without pre-injury anticoagulant therapy identified several independent risk factors for coagulopathy which were present at hospital admission. Glasgow Coma Scale (GCS) less than or equal to 8, base excess (BE) less than or equal to − 6, hypothermia and hypotension increased risk significantly. Conclusion - Consideration of these factors enables early prediction and risk stratification of acute coagulopathy after TBI, thus guiding clinical management

    QRS micro-fragmentation as a mortality predictor.

    Get PDF
    AIMS Fragmented QRS complex with visible notching on standard 12-lead electrocardiogram (ECG) is understood to represent depolarization abnormalities and to signify risk of cardiac events. Depolarization abnormalities with similar prognostic implications likely exist beyond visual recognition but no technology is presently suitable for quantification of such invisible ECG abnormalities. We present such a technology. METHODS AND RESULTS A signal processing method projects all ECG leads of the QRS complex into optimized three perpendicular dimensions, reconstructs the ECG back from this three-dimensional projection, and quantifies the difference (QRS 'micro'-fragmentation, QRS-μf) between the original and reconstructed signals. QRS 'micro'-fragmentation was assessed in three different populations: cardiac patients with automatic implantable cardioverter-defibrillators, cardiac patients with severe abnormalities, and general public. The predictive value of QRS-μf for mortality was investigated both univariably and in multivariable comparisons with other risk factors including visible QRS 'macro'-fragmentation, QRS-Mf. The analysis was made in a total of 7779 subjects of whom 504 have not survived the first 5 years of follow-up. In all three populations, QRS-μf was strongly predictive of survival (P < 0.001 univariably, and P < 0.001 to P = 0.024 in multivariable regression analyses). A similar strong association with outcome was found when dichotomizing QRS-μf prospectively at 3.5%. When QRS-μf was used in multivariable analyses, QRS-Mf and QRS duration lost their predictive value. CONCLUSION In three populations with different clinical characteristics, QRS-μf was a powerful mortality risk factor independent of several previously established risk indices. Electrophysiologic abnormalities that contribute to increased QRS-μf values are likely responsible for the predictive power of visible QRS-Mf. KEY QUESTION KEY FINDING TAKE-HOME MESSAGE QRS-μf is a strong predictor of worsened survival. It can be assessed in standard short-term 12-lead electrocardiograms
    • …
    corecore