21 research outputs found
A worldwide survey on incidence, management and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: The POTTER-AF study.
AIMS
Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management and outcome are sparse.
METHODS AND RESULTS
This international multicenter registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553,729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed at 214 centers in 35 countries. In 78 centers 138 patients (0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (p<0.0001)) were diagnosed with an oesophageal fistula. Periprocedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8%, and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) (odds ratio 7.463 (2.414, 23.072) p<0.001).
CONCLUSIONS
Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high
Phrenic Nerve Injury During Cryoballoon-Based Pulmonary Vein Isolation: Results of the Worldwide YETI Registry.
BackgroundCryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce.MethodsThe YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible.ResultsA total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months.ConclusionsThe incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article
Modelling human choices: MADeM and decision‑making
Research supported by FAPESP 2015/50122-0 and DFG-GRTK 1740/2. RP and AR are also part of the Research, Innovation and Dissemination Center for Neuromathematics FAPESP grant (2013/07699-0). RP is supported by a FAPESP scholarship (2013/25667-8). ACR is partially supported by a CNPq fellowship (grant 306251/2014-0)
25th annual computational neuroscience meeting: CNS-2016
The same neuron may play different functional roles in the neural circuits to which it belongs. For example, neurons in the Tritonia pedal ganglia may participate in variable phases of the swim motor rhythms [1]. While such neuronal functional variability is likely to play a major role the delivery of the functionality of neural systems, it is difficult to study it in most nervous systems. We work on the pyloric rhythm network of the crustacean stomatogastric ganglion (STG) [2]. Typically network models of the STG treat neurons of the same functional type as a single model neuron (e.g. PD neurons), assuming the same conductance parameters for these neurons and implying their synchronous firing [3, 4]. However, simultaneous recording of PD neurons shows differences between the timings of spikes of these neurons. This may indicate functional variability of these neurons. Here we modelled separately the two PD neurons of the STG in a multi-neuron model of the pyloric network. Our neuron models comply with known correlations between conductance parameters of ionic currents. Our results reproduce the experimental finding of increasing spike time distance between spikes originating from the two model PD neurons during their synchronised burst phase. The PD neuron with the larger calcium conductance generates its spikes before the other PD neuron. Larger potassium conductance values in the follower neuron imply longer delays between spikes, see Fig. 17.Neuromodulators change the conductance parameters of neurons and maintain the ratios of these parameters [5]. Our results show that such changes may shift the individual contribution of two PD neurons to the PD-phase of the pyloric rhythm altering their functionality within this rhythm. Our work paves the way towards an accessible experimental and computational framework for the analysis of the mechanisms and impact of functional variability of neurons within the neural circuits to which they belong
Evaluation eines neuen, autokalibrierten Verfahrens der kontinuierlichen arteriellen Pulskonturanalyse zur Bestimmung des Herzzeitvolumens: Vergleich mit der transkardiopulmonalen Thermodilution
Zahlreiche Studien konnten zeigen, dass eine zielgerichtete hämodynamische Therapie mittels Katecholaminen und/oder Volumen basierend auf Therapiealgorithmen das Outcome von Patienten verbessern kann. Die Ermittlung des individuellen Herzindex und dessen Optimierung spielt daher eine große Rolle. Jahrzehntelang war die Bestimmung des Herzindex mit invasiven Maßnahmen verbunden. Aufgrund des ungünstigen Nutzen-Risikoprofils wurde in den letzten Jahren an weniger invasiven Methoden zur Messung des Herzindex gearbeitet. Eine dieser Methoden ist die Pulskonturanalyse. Monitorsysteme auf Basis der Pulskonturanalyse sind durch Analyse der arteriellen Kurvenform in der Lage „Schlag-auf-Schlag“ den Herzindex zu bestimmen. Nach Eingabe patientenspezifischer Daten funktionieren diese Systeme unkalibriert. Das in der vorliegenden Dissertation untersuchte Monitorsystem verwendet einen speziellen Autokalibrationsalgorithmus. Dieses System führt initial eine Autokalibration zur Bestimmung der individuellen vaskulären Compliance durch und kalkuliert einen initialen Herzindex. Dieser dient als Ausgangswert für die weitere kontinuierliche Bestimmung. Das Ziel der vorliegenden Dissertation war es, die Genauigkeit der autokalibrierten Pulskonturanalyse hinsichtlich der Bestimmung des Herzindex im Vergleich zur transkardiopulmonalen Thermodilution zu untersuchen. Die Messungen wurden bei Patienten die sich einer elektiven koronaren Bypassoperation unterziehen mussten vor und nach kardiopulmonalem Bypass durchgeführt. Zusammenfassend lässt sich feststellen, dass das untersuchte autokalibrierte Monitorsystem auf Basis der Pulskonturanalyse nicht ausreichend genau in der Lage war, Absolutwerte des Herzindex zu erfassen und hämodynamische Trends zu reflektieren. Für den klinisch tätigen Arzt ist jedoch neben der genauen Bestimmung des Herzindex die zuverlässige Anzeige hämodynamischer Trends zur zielgerichteten hämodynamischen Optimierung von großer Bedeutung
High-dose methylprednisolone pulse therapy during refractory COVID-19 acute respiratory distress syndrome: a retrospective observational study
Background
Current COVID-19 guidelines recommend the early use of systemic corticoids for COVID-19 acute respiratory distress syndrome (ARDS). It remains unknown if high-dose methylprednisolone pulse therapy (MPT) ameliorates refractory COVID-19 ARDS after many days of mechanical ventilation or rapid deterioration with or without extracorporeal membrane oxygenation (ECMO).
Methods
This is a retrospective observational study. Consecutive patients with COVID-19 ARDS treated with a parenteral high-dose methylprednisolone pulse therapy at the intensive care units (ICU) of two University Hospitals between January 1st 2021 and November 30st 2022 were included. Clinical data collection was at ICU admission, start of MPT, 3-, 10- and 14-days post MPT.
Results
Thirty-seven patients (mean age 55 ± 12 years) were included in the study. MPT started at a mean of 17 ± 12 days after mechanical ventilation. Nineteen patients (54%) received ECMO support when commencing MPT. Mean paO2/FiO2 significantly improved 3- (p = 0.034) and 10 days (p = 0.0313) post MPT. The same applied to the necessary FiO2 10 days after MPT (p = 0.0240). There were no serious infectious complications. Twenty-four patients (65%) survived to ICU discharge, including 13 out of 20 (65%) needing ECMO support.
Conclusions
Late administration of high-dose MPT in a critical subset of refractory COVID-19 ARDS patients improved respiratory function and was associated with a higher-than-expected survival of 65%. These data suggest that high-dose MPT may be a viable salvage therapy in refractory COVID-19 ARDS
Electrophysiology lab efficiency comparison between cryoballoon and point-by-point radiofrequency ablation: a German sub-analysis of the FREEZE Cohort study
Abstract Background Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). Methods The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. Results The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients’ characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). Conclusion CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011)
Phrenic Nerve Injury During Cryoballoon-Based Pulmonary Vein Isolation: Results of the Worldwide YETI Registry
BACKGROUND
Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce.
METHODS
The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible.
RESULTS
A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months.
CONCLUSIONS
The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article
Impact of cryoballoon application abortion due to phrenic nerve injury on reconnection rates: a YETI subgroup analysis
AimsCryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures.Methods and resultsIn the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence.ConclusionIn patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures.Clinical trial registrationhttps://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577