130 research outputs found

    Incoherent Interplane Conductivity of kappa-(BEDT-TTF)2Cu[N(CN)2]Br

    Full text link
    The interplane optical spectrum of the organic superconductor kappa-(BEDT-TTF)2Cu[N(CN)2]Br was investigated in the frequency range from 40 to 40,000 cm-1. The optical conductivity was obtained by Kramers-Kronig analysis of the reflectance. The absence of a Drude peak at low frequency is consistent with incoherent conductivity but in apparent contradiction to the metallic temperature dependence of the DC resistivity. We set an upper limit to the interplane transfer integral of tb = 0.1 meV. A model of defect-assisted interplane transport can account for this discrepancy. We also assign the phonon lines in the conductivity to the asymmetric modes of the ET molecule.Comment: 7 pages with embedded figures, submitted to PR

    Euclid preparation: XVII. Cosmic dawn survey: Spitzer space telescope observations of the Euclid deep fields and calibration fields

    Get PDF
    Galaxie

    Euclid preparation. XV. Forecasting cosmological constraints for the Euclid and CMB joint analysis

    Get PDF
    Galaxie

    Euclid preparation: XVIII. The NISP photometric system

    Get PDF
    Galaxie

    Chloroquine analogs as antimalarial candidates with potent in vitro and in vivo activity

    No full text
    In spite of recent efforts to eradicate malaria in the world, this parasitic disease is still considered a major public health problem, with a total of 216 million cases of malaria and 445,000 deaths in 2016. Artemisinin-based combination therapies remain effective in most parts of the world, but recent cases of resistance in Southeast Asia have urged for novel approaches to treat malaria caused by Plasmodium falciparum. In this work, we present chloroquine analogs that exhibited high activity against sensitive and chloroquine-resistant P. falciparum blood parasites and were also active against P. berghei infected mice. Among the compounds tested, DAQ, a chloroquine analog with a more linear side chain, was shown to be the most active in vitro and in vivo, with low cytotoxicity, and therefore may serve as the basis for the development of more effective chloroquine analogs to aid malaria eradication. Keywords: Malaria, Chloroquine, Resistance, Drug desig

    Consistency of FDG-PET Accuracy and Cost-Effectiveness in Initial Staging of Patients With Hodgkin Lymphoma Across Jurisdictions.

    No full text
    INTRODUCTION: Two hundred ten patients with newly diagnosed Hodgkin's lymphoma (HL) were consecutively enrolled in this prospective trial to evaluate the cost-effectiveness of fluorine-18 ((18)F)-fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET) scan in initial staging of patients with HL. METHODS: All 210 patients were staged with conventional clinical staging (CCS) methods, including computed tomography (CT), bone marrow biopsy (BMB), and laboratory tests. Patients were also submitted to metabolic staging (MS) with whole-body FDG-PET scan before the beginning of treatment. A standard of reference for staging was determined with all staging procedures, histologic examination, and follow-up examinations. The accuracy of the CCS was compared with the MS. Local unit costs of procedures and tests were evaluated. Incremental cost-effectiveness ratio (ICER) was calculated for both strategies. RESULTS: In the 210 patients with HL, the sensitivity for initial staging of FDG-PET was higher than that of CT and BMB in initial staging (97.9% vs. 87.3%; P < .001 and 94.2% vs. 71.4%, P < 0.003, respectively). The incorporation of FDG-PET in the staging procedure upstaged disease in 50 (24%) patients and downstaged disease in 17 (8%) patients. Changes in treatment would be seen in 32 (15%) patients. Cumulative cost for staging procedures was 3751/patientforCCScomparedto3751/patient for CCS compared to 5081 for CCS + PET and 4588forPET/CT.TheICERofPET/CTstrategywas4588 for PET/CT. The ICER of PET/CT strategy was 16,215 per patient with modified treatment. PET/CT costs at the beginning and end of treatment would increase total costs of HL staging and first-line treatment by only 2%. CONCLUSION: FDG-PET is more accurate than CT and BMB in HL staging. Given observed probabilities, FDG-PET is highly cost-effective in the public health care program in Brazil

    Euclid preparation. X. The Euclid photometric-redshift challenge

    Get PDF
    Forthcoming large photometric surveys for cosmology require precise and accurate photometric redshift (photo-z) measurements for the success of their main science objectives. However, to date, no method has been able to produce photo-zs at the required accuracy using only the broad-band photometry that those surveys will provide. An assessment of the strengths and weaknesses of current methods is a crucial step in the eventual development of an approach to meet this challenge. We report on the performance of 13 photometric redshift code single value redshift estimates and redshift probability distributions (PDZs) on a common set of data, focusing particularly on the 0.2 − 2.6 redshift range that the Euclid mission will probe. We designed a challenge using emulated Euclid data drawn from three photometric surveys of the COSMOS field. The data was divided into two samples: one calibration sample for which photometry and redshifts were provided to the participants; and the validation sample, containing only the photometry to ensure a blinded test of the methods. Participants were invited to provide a redshift single value estimate and a PDZ for each source in the validation sample, along with a rejection flag that indicates the sources they consider unfit for use in cosmological analyses. The performance of each method was assessed through a set of informative metrics, using cross-matched spectroscopic and highly-accurate photometric redshifts as the ground truth. We show that the rejection criteria set by participants are efficient in removing strong outliers, that is to say sources for which the photo-z deviates by more than 0.15(1 + z) from the spectroscopic-redshift (spec-z). We also show that, while all methods are able to provide reliable single value estimates, several machine-learning methods do not manage to produce useful PDZs. We find that no machine-learning method provides good results in the regions of galaxy color-space that are sparsely populated by spectroscopic-redshifts, for example z >  1. However they generally perform better than template-fitting methods at low redshift (z <  0.7), indicating that template-fitting methods do not use all of the information contained in the photometry. We introduce metrics that quantify both photo-z precision and completeness of the samples (post-rejection), since both contribute to the final figure of merit of the science goals of the survey (e.g., cosmic shear from Euclid). Template-fitting methods provide the best results in these metrics, but we show that a combination of template-fitting results and machine-learning results with rejection criteria can outperform any individual method. On this basis, we argue that further work in identifying how to best select between machine-learning and template-fitting approaches for each individual galaxy should be pursued as a priority
    • …
    corecore