42 research outputs found

    Prospective association of occupational and leisure-time physical activity with orthostatic blood pressure changes in older adults

    Get PDF
    \ua9 2023, The Author(s).Orthostatic hypotension (OH) is common in older people. We examined the influence of self-reported occupational-related physical activity (PA) and leisure-time physical exercise (PE) on orthostatic response in a sample of older people over a 2 year period. Supine and orthostatic systolic blood pressure (sBP), diastolic blood pressure (dBP), and mean blood pressure (mBP) were assessed in response to Active Stand (AS) test in 205 older subjects (> 60 years old) at baseline and 2-year follow-up. OH was found in 24 subjects (11.71%) at baseline and 20 subjects (9.76%) after 2 years, with a significant degree of variability in the occurrence of OH after 2 years. Twenty-two subjects who had OH at baseline were free of it after 2 years, two subjects had persistent OH at baseline and after 2 years. After 2 years, adults with occupational PA showed no significant decrease of blood pressure in response to AS test, while lack of undertaking an occupation-related PA was significantly related with a greater decrease in sBP and mBP in response to AS testing in the 1st min. Occupation-related PA and leisure-time-related PE were related to an increase in the response of BP on AS in change between baseline and after 2 years. High between-subjects variance in OH over 2 years was noted. Occupations that involved continuous physical activity and leisure-time physical exercise in middle age were both protective for BP decline on orthostatic stress test within 2 years

    Data filtering in the readout of the CMS Electromagnetic Calorimeter

    Get PDF
    For an efficient data taking, the Electromagnetic Calorimeter (ECAL) data of the CMS experiment must be limited to 10\% of the full event size (1MB). Other requirements limit the average data size to 2kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the ECAL detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor

    "Pi of the Sky" - all-sky, real-time search for fast optical transients

    Full text link
    An apparatus to search for optical flashes in the sky is described. It has been optimized for gamma ray bursts (GRB) optical counterparts. It consists of 2x16 cameras covering all the sky. The sky is monitored continuously and the data are analysed on-line. It has self-triggering capability and can react to external triggers with negative delay. The prototype with two cameras has been installed at Las Campanas (Chile) and is operational from July 2004. The paper presents general idea and describes the apparatus in detail. Performance of the prototype is briefly reviewed and perspectives for the future are outlined

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    The ATLAS fast tracKer system

    Get PDF
    The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited η-ϕ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation. © The ATLAS collaboratio

    FPGA and Embedded PC Based Module for Research and

    No full text
    This paper presents a versatile experimental and educational module, which can be used both for prototyping of embedded PC based electronic devices, and for teaching of computer engineering. The FPGA chip may be used to implement or to emulate wide range of hardware devices, while the embedded PC, able to run the Linux OS, provides an efficient environment for controlling this hardware using different techniques
    corecore