1,139 research outputs found

    Smart Technologies for Environmental Safety and Knowledge Enhancement in Intermodal Transport

    Get PDF
    International concerns about security in transport systems are leading to a new international regulation in this field. This introduces new requirements for operators and authorities as well as it opens new challenges, in particular when referred to seaports and maritime transport in the Mediterranean area, where many seaport terminals and infrastructures are affected by a noteworthy technological divide from North European contexts. In such contexts, the adoption of the new regulations can represent the right chance for upgrading the local operative standards, increasing latu sensu the quality of maritime transport performances, while conferring a greater level to security and safety checks. This paper explores the chances for increasing the level of Mediterranean seaport competitiveness allowed by technological innovations in transport systems, both in operations and organization of these infrastructures. The aim of the work is to study the effects of the adoption of technological solutions such as wireless communications and radiofrequency identification on the competitiveness of Mediterranean seaport infrastructures. Technological solutions designed to identify good items help operators in organizing activities in terminals and make maritime transport faster in delivering goods, by cutting the handling time and costs in seaport terminals. Seaports that adopt this kind of technologies, and the surrounding economic areas connected to seaports, have a greater attractiveness on shipping companies and operators, since they allow faster handling activities and easier checks on goods. Besides, the analysis of direct and indirect effects of the use of such technologies specifically focuses on the contribution that the use of these solutions gives in ensuring higher security levels, by increasing the level of information and knowledge associated to goods. The different types of security provided (e.g. for people, environment and goods) and the extreme flexibility of the technologies involved give the overall worth of the challenge. It seems to be a great chance of growth for the Mediterranean area, more than a mere compliance to the international security regulations.

    Study of a constrained finite element elbow prosthesis: the influence of the implant placement

    Get PDF
    BackgroundThe functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions.Materials and methodsBy means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by +/- 3 degrees.ResultsThe greatest von Mises stress state in the bone component for the 90 degrees working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0 degrees and 145 degrees showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90 degrees (- 3 degrees in the sagittal plane, 0 degrees in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement.ConclusionThe areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90 degrees. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.Level of evidence:

    Rituximab-induced hypogammaglobulinaemia in patients affected by idiopathic inflammatory myopathies: a multicentre study

    Get PDF
    Objective Rituximab (RTX) is an anti-CD20 chimeric monoclonal antibody recommended as off-label treatment in patients with idiopathic inflammatory myopathies (IIM). The present study aimed to evaluate changes in immunoglobulin (Ig) levels during RTX-treatment and their potential association with infections in a cohort of IIM patients.Methods Patients evaluated in the Myositis clinic belonging to the Rheumatology Units of Siena, Bari and Palermo University Hospitals, and treated for the first time with RTX were enrolled. Demographic, clinical, laboratory and treatment variables, including previous and concomitant immunosuppressive drugs and glucocorticoid (GC) dosage were analysed before (T0) and after 6 (T1) and 12 (T2) months of RTX treatment.Results Thirty patients (median age, IQR 56 (42-66); 22 female) were selected. During the observational period, low levels of IgG (<700 mg/dl) and IgM (<40 mg/dl) occurred in 10% and 17% of patients, respectively. However, no one showed severe (IgG<400 mg/dl) hypogammaglobulinaemia. IgA concentrations were lower at T1 than T0 (p=0.0218), while IgG concentrations were lower at T2 compared to those at baseline (p=0.0335). IgM concentrations were lower at T1 and T2 than T0 (p<0.0001), as well at T2 than T1 (p=0.0215). Three patients suffered major infections, two others had paucisymptomatic COVID-19, one suffered from mild zoster. GC dosages at T0 were inversely correlated with IgA T0 concentrations (p=0.004, r=-0.514). No correlation was found between demographic, clinical and treatment variables and Ig serum levels.Conclusion Hypogammaglobulinaemia following RTX is uncommon in IIM and is not related to any clinical variables, including GC dosage and previous treatments. IgG and IgM monitoring after RTX treatment does not seem useful in stratifying patients who require closer safety monitoring and prevention of infection, due to the lack of association between hypogammaglobulinaemia and the onset of severe infections

    Liver and intestinal protective effects of Castanea sativa Mill. bark extract in high-fat diet rats

    Get PDF
    The effects of Castanea sativa Mill. have been studied in high fat diet (HFD) overweight rats. Natural Extract of Chestnut bark (Castanea sativa Mill.) (ENC®), rich in ellagitannins, has been studied in 120 male Sprague-Dawley rats, divided in four groups. Two groups were controls: regular (RD) and HDF diet. Two groups received ENC®(20 mg/kg/day): RD + ENC®and HFD + ENC®. At baseline and at 7, 14 and 21 days, weight gain, serum lipids, plasma cytokines, liver histology, microsomial enzymes and oxidation, intestinal oxidative stress and contractility were studied. HFD increased body weight, increased pro-inflammatory cytokines, induced hepatocytes microvescicular steatosis, altered microsomial, increased liver and intestinal oxidative stress, deranged intestinal contractility. In HFD-fed rats, ENC®exerted antiadipose and antioxidative activities and normalized intestinal contractility, suggesting a potential approach to overweight management associated diseases

    Combined Forward-Backward Asymmetry Measurements in Top-Antitop Quark Production at the Tevatron

    Get PDF
    The CDF and D0 experiments at the Fermilab Tevatron have measured the asymmetry between yields of forward- and backward-produced top and antitop quarks based on their rapidity difference and the asymmetry between their decay leptons. These measurements use the full data sets collected in proton-antiproton collisions at a center-of-mass energy of s=1.96\sqrt s =1.96 TeV. We report the results of combinations of the inclusive asymmetries and their differential dependencies on relevant kinematic quantities. The combined inclusive asymmetry is AFBttˉ=0.128±0.025A_{\mathrm{FB}}^{t\bar{t}} = 0.128 \pm 0.025. The combined inclusive and differential asymmetries are consistent with recent standard model predictions

    Saethre-Chotzen syndrome : cranofacial anomalies caused by genetic changes in the TWIST gene

    Get PDF
    In this thesis, one of the most frequently occurring and most variable craniosynostosis syndromes was investigated; Saethre-Chotzen syndrome. Craniosynostosis is the premature obliteration of cranial sutures in the developing embryo. It can also occur in the first few months of life. Saethre-Chotzen syndrome is, besides craniosynostosis, characterized by specific facial and limb abnormalities, of which the most frequently reported are ptosis, prominent crus helicis, cutaneous syndactyly of digit 2 and 3 on both hands and feet, and broad halluces. Saethre-Chotzen syndrome has been linked to the TWIST gene on chromosome 7p21.1. Mutations in and variably sized deletions of this gene can be found in patients with clinical features of Saethre-Chotzen syndrome. The latter, TWIST deletions, often also include part of the surrounding chromosome 7p and are reported to be associated with mental retardation. In Saethre-Chotzen patients, in whom neither a mutation nor a deletion of TWIST had been found, the FGFR3 P250R mutation was in some cases detected. This mutation has specifically been linked to Muenke syndrome that is characterized by unior bicoronal synostosis and slight facial dysmorphology. However, a Saethre-Chotzen like phenotype can also result from this mutation. Because of the possible overlap of Saethre-Chotzen with Muenke syndrome, these syndromes were studied in order to provide clinical criteria that discriminate between the two (chapter 4). Many phenotypic features occur in both syndromes. In addition, although unicoronal synostosis occurs slightly more frequently in Muenke syndrome, unicoronal and bicoronal synostosis are seen in both syndromes. The discrimination between Saethre-Chotzen and Muenke is often not made easily and the associated genes, TWIST and FGFR3, respectively, are simultaneously tested for pathogenic m

    Molecular dynamics simulation of aqueous solutions of 26-unit segments of p(NIPAAm) and of p(NIPAAm) "doped" with amino acid based comonomers

    Get PDF
    We have performed 75-ns molecular dynamics (MD) simulations of aqueous solutions of a 26-unit NIPAAm oligomer at two temperatures, 302 and 315 K, below and above the experimentally determined lower critical solution temperature (LCST) of p(NIPAAm). We have been able to show that at 315 K the oligomer assumes a compact form, while it keeps a more extended form at 302 K. A similar behavior has been demonstrated for a similar NIPAAm oligomer, where two units had been substituted by methacryloyl-l-valine (MAVA) comonomers, one of them being charged and one neutral. For another analogous oligomer, where the same units had been substituted by methacryloyl-l-leucine (MALEU) comonomers, no transition from the extended to the more compact conformation has been found within the same simulation time. Statistical analysis of the trajectories indicates that this transition is related to the dynamics of the oligomer backbone, and to the formation of intramolecular hydrogen bonds and water-bridges between distant units of the solute. In the MAVA case, we have also evidenced an important role of the neutral MAVA comonomer in stabilizing the compact coiled structure. In the MALEU case, the corresponding comonomer is not equally efficacious and, possibly, is even hindering the readjustment of the oligomer backbone. Finally the self-diffusion coefficient of water molecules surrounding the oligomers at the two temperatures for selected relevant times is observed to characteristically depend on the distance from the solute molecules

    Nonlinear beam self-cleaning in a coupled cavity composite laser based on multimode fiber

    Get PDF
    We study a coupled cavity laser configuration where a passively Q-switched Nd:YAG microchip laser is combined with an extended cavity, including a doped multimode fiber. For appropriate coupling levels with the extended cavity, we observed that beam selfcleaning was induced in the multimode fiber thanks to nonlinear modal coupling, leading to a quasi-single mode laser output. In the regime of beam self-cleaning, laser pulse duration was reduced from 525 to 225 ps. We also observed a Q-switched mode-locked operation, where spatial self-cleaning was accompanied by far-detuned nonlinear frequency conversion in the active multimode fiber
    corecore