14 research outputs found

    Development of a Novel Composite Process Measure for Venous Thromboembolism Prophylaxis.

    No full text
    BACKGROUND: Postoperative venous thromboembolism (VTE) is important clinically, and VTE quality metrics are used in public reporting and pay-for-performance programs. However, current VTE outcome measures are not valid due to surveillance bias, and the Surgical Care Improvement Project (SCIP-VTE-2) process measure only requires prophylaxis within 24 hours of surgery. OBJECTIVES: We sought to (1) develop a novel measure of VTE prophylaxis that requires early ambulation, mechanical prophylaxis, and chemoprophylaxis throughout the hospitalization, and (2) compare hospital performance on the SCIP-VTE-2 process measure to this novel measure. RESEARCH DESIGN: A new composite measure of ambulation, sequential compression device (SCD), and chemoprophylaxis component measures was developed. The ambulation component required daily ambulation, the SCD component required documentation of continuous use, and the chemoprophylaxis component required patient-appropriate and medication-appropriate dosing and administration. Requirements could also be met with component-specific exceptions. Surgical patients at an academic center from 2012 to 2013 were assessed for SCIP-VTE-2 and composite measure adherence. RESULTS: Of 786 patients, 589 (74.9%) passed the ambulation measure, 494 (62.8%) passed the SCD measure, and 678 (86.3%) passed the chemoprophylaxis measure. A total of 268 (91.8%) SCD failures and 46 (42.6%) chemoprophylaxis failures were ordered but not administered. When comparing the 2 measures, 784 (99.7%) passed SCIP-VTE-2, whereas only 364 (46.3%) passed the composite measure (P\u3c0.001). CONCLUSIONS: This new measure incorporates the critical aspects of VTE prevention to ensure defect-free care. After additional evaluation, this composite VTE prophylaxis measure with appropriate exclusion criteria may be a better alternative to existing VTE process and outcome measures

    Evaluation of an institutional project to improve venous thromboembolism prevention.

    No full text
    BACKGROUND: Northwestern Memorial Hospital (NMH) was historically a poor performer on the venous thromboembolism (VTE) outcome measure. As this measure has been shown to be flawed by surveillance bias, NMH embraced process-of-care measures to ensure appropriate VTE prophylaxis to assess healthcare-associated VTE prevention efforts. OBJECTIVE: To evaluate the impact of an institution-wide project aimed at improving hospital performance on VTE prophylaxis measures. DESIGN: A retrospective observational study. SETTING: NMH, an 885-bed academic medical center in Chicago, Illinois PATIENTS: Inpatients admitted to NMH from January 1, 2013 to May 1, 2013 and from October 1, 2014 to April 1, 2015 were eligible for evaluation. INTERVENTION: Using the define-measure-analyze-improve-control (DMAIC) process-improvement methodology, a multidisciplinary team implemented and iteratively improved 15 data-driven interventions in 4 broad areas: (1) electronic medical record (EMR) alerts, (2) education initiatives, (3) new EMR order sets, and (4) other EMR changes. MEASUREMENTS: The Joint Commission\u27s 6 core measures and the Surgical Care Improvement Project (SCIP) SCIP-VTE-2 measure. RESULTS: Based on 3103 observations (1679 from January 1, 2013 to May 1, 2013, and 1424 from October 1, 2014 to April 1, 2015), performance on the core measures improved. Performance on measure 1 (chemoprophylaxis) improved from 82.5% to 90.2% on medicine services, and from 94.4% to 97.6% on surgical services. The largest improvements were seen in measure 4 (platelet monitoring), with a performance increase from 76.7% adherence to 100%, and measure 5 (warfarin discharge instructions), with a performance increase from 27.4% to 88.8%. CONCLUSION: A systematic hospital-wide DMAIC project improved VTE prophylaxis measure performance. Sustained performance has been observed, and novel control mechanisms for continued performance surveillance have been embedded in the hospital system. Journal of Hospital Medicine 2016;11:S29-S37. © 2016 Society of Hospital Medicine

    Square channels formed by a peptide derived from transthyretin.

    No full text
    High-resolution structures of peptide supramolecular assemblies are key to understanding amyloid diseases and designing peptide-based materials. This paper explores the supramolecular assembly of a macrocyclic β-sheet peptide derived from transthyretin (TTR). The peptide mimics the β-hairpin formed by the β-strands G and H of TTR, which form the interface of the TTR tetramer. X-ray crystallography reveals that the peptide does not form a tetramer, but rather assembles to form square channels. The square channels are formed by extended networks of β-sheets and pack in a "tilted windows" pattern. This unexpected structure represents an emergent property of the peptide and broadens the scope of known supramolecular assemblies of β-sheets
    corecore